Task #253 — E2E CLI test scripts + FOCAS test-client CLI
The driver-layer integration tests confirm the driver sees the PLC, and
the Client.CLI tests confirm the client sees the server. Nothing glued
them end-to-end until this PR.
- scripts/e2e/_common.ps1: shared helpers — CLI invocation (published-
binary OR `dotnet run` fallback), Test-Probe / Test-DriverLoopback /
Test-ServerBridge (all return @{Passed;Reason} hashtables).
- scripts/e2e/test-<modbus|abcip|ablegacy|s7|focas|twincat>.ps1: per-
driver three-stage script (probe → driver-loopback → server-bridge).
AB Legacy / FOCAS / TwinCAT are gated behind *_TRUST_WIRE env vars
since they need real hardware (#222) or a licensed runtime (#221).
- scripts/e2e/test-phase7-virtualtags.ps1: writes a Modbus HR, reads
the server-side VirtualTag (VT = input * 2) back via OPC UA, triggers
+ clears a scripted alarm. Exercises the Phase 7 CachedTagUpstreamSource
+ ScriptedAlarmEngine path.
- scripts/e2e/test-all.ps1: reads e2e-config.json sidecar, runs each
present driver, prints a FINAL MATRIX (PASS/FAIL/SKIP). Missing
sections SKIP rather than fail hard.
- scripts/e2e/e2e-config.sample.json: commented sample — each dev's
NodeIds are local-seed-specific so e2e-config.json is .gitignore-d.
- scripts/e2e/README.md: full walkthrough — prereqs, three-stage design,
env-var gates, expected matrix, why this is separate from `dotnet test`.
Tasks #249-#251 shipped Modbus/AbCip/AbLegacy/S7/TwinCAT CLIs but left
FOCAS out. Since test-focas.ps1 needs it, the 6th CLI ships here:
- src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli: probe/read/write/subscribe
commands, AssemblyName `otopcua-focas-cli`. WriteCommand.ParseValue
handles the full FocasDataType enum (Bit/Byte/Int16/Int32/Float32/
Float64/String — no UInt variants; the FOCAS protocol exposes signed
PMC + Fanuc-Float only). Default DataType is Int16 to match the PMC
register convention.
Full-solution build clean (0 errors). FOCAS CLI wired into
ZB.MOM.WW.OtOpcUa.slnx. No .Tests project for the FOCAS CLI yet —
symmetric with how ProbeCommand has no unit-testable pure logic in the
other 5 CLIs either; WriteCommand.ParseValue parity will land in a
follow-up to keep this PR scoped.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
82
scripts/e2e/test-s7.ps1
Normal file
82
scripts/e2e/test-s7.ps1
Normal file
@@ -0,0 +1,82 @@
|
||||
#Requires -Version 7.0
|
||||
<#
|
||||
.SYNOPSIS
|
||||
End-to-end CLI test for the Siemens S7 driver bridged through the OtOpcUa server.
|
||||
|
||||
.DESCRIPTION
|
||||
Probe + driver-loopback + server-bridge against a Siemens S7-300/400/1200/1500
|
||||
or compatible soft-PLC. python-snap7 simulator (task #216) or real hardware
|
||||
both work.
|
||||
|
||||
Prereqs:
|
||||
- S7 simulator / PLC on $S7Host:$S7Port
|
||||
- On real S7-1200/1500: PUT/GET communication enabled in TIA Portal.
|
||||
- OtOpcUa server running with an S7 DriverInstance bound to the same
|
||||
endpoint + a Tag at DB1.DBW0 Int16 published under -BridgeNodeId.
|
||||
|
||||
.PARAMETER S7Host
|
||||
Host:port of the S7 simulator / PLC. Default 127.0.0.1:102.
|
||||
|
||||
.PARAMETER Cpu
|
||||
S7200 / S7200Smart / S7300 / S7400 / S71200 / S71500 (default S71500).
|
||||
|
||||
.PARAMETER Slot
|
||||
CPU slot. Default 0 (S7-1200/1500). S7-300 uses 2.
|
||||
|
||||
.PARAMETER Address
|
||||
S7 address to exercise. Default DB1.DBW0.
|
||||
|
||||
.PARAMETER OpcUaUrl
|
||||
OtOpcUa server endpoint.
|
||||
|
||||
.PARAMETER BridgeNodeId
|
||||
NodeId at which the server publishes the Address.
|
||||
#>
|
||||
|
||||
param(
|
||||
[string]$S7Host = "127.0.0.1:102",
|
||||
[string]$Cpu = "S71500",
|
||||
[int]$Slot = 0,
|
||||
[string]$Address = "DB1.DBW0",
|
||||
[string]$OpcUaUrl = "opc.tcp://localhost:4840",
|
||||
[Parameter(Mandatory)] [string]$BridgeNodeId
|
||||
)
|
||||
|
||||
$ErrorActionPreference = "Stop"
|
||||
. "$PSScriptRoot/_common.ps1"
|
||||
|
||||
$hostPart, $portPart = $S7Host.Split(":")
|
||||
$port = [int]$portPart
|
||||
|
||||
$s7Cli = Get-CliInvocation `
|
||||
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Driver.S7.Cli" `
|
||||
-ExeName "otopcua-s7-cli"
|
||||
$opcUaCli = Get-CliInvocation `
|
||||
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Client.CLI" `
|
||||
-ExeName "otopcua-cli"
|
||||
|
||||
$commonS7 = @("-h", $hostPart, "-p", $port, "-c", $Cpu, "--slot", $Slot)
|
||||
$results = @()
|
||||
|
||||
$results += Test-Probe `
|
||||
-Cli $s7Cli `
|
||||
-ProbeArgs (@("probe") + $commonS7)
|
||||
|
||||
$writeValue = Get-Random -Minimum 1 -Maximum 9999
|
||||
$results += Test-DriverLoopback `
|
||||
-Cli $s7Cli `
|
||||
-WriteArgs (@("write") + $commonS7 + @("-a", $Address, "-t", "Int16", "-v", $writeValue)) `
|
||||
-ReadArgs (@("read") + $commonS7 + @("-a", $Address, "-t", "Int16")) `
|
||||
-ExpectedValue "$writeValue"
|
||||
|
||||
$bridgeValue = Get-Random -Minimum 10000 -Maximum 19999
|
||||
$results += Test-ServerBridge `
|
||||
-DriverCli $s7Cli `
|
||||
-DriverWriteArgs (@("write") + $commonS7 + @("-a", $Address, "-t", "Int16", "-v", $bridgeValue)) `
|
||||
-OpcUaCli $opcUaCli `
|
||||
-OpcUaUrl $OpcUaUrl `
|
||||
-OpcUaNodeId $BridgeNodeId `
|
||||
-ExpectedValue "$bridgeValue"
|
||||
|
||||
Write-Summary -Title "S7 e2e" -Results $results
|
||||
if ($results | Where-Object { -not $_.Passed }) { exit 1 }
|
||||