fix(alarms): #647 review — Raise on an active condition is a re-statement; FOCAS outage quality + health
MAJOR-1: a deploy that changes a driver's config respawns it, and the fresh instance's empty told record re-sent Raise for every still-active alarm, un-acking acknowledged conditions and writing a duplicate "Activated" alerts row. NativeAlarmProjector now treats Raise on an already-active condition as a re-statement (keeps Acked; ForwardNativeAlarm skips the alerts row); only Retrigger (or inactive->active) un-acks. Sources whose upstream ack state is authoritative send Retrigger for an unacked re-statement: OpcUaClient on first sight (no prior told), Galaxy for an unacked active snapshot entry. Runtime E2E drives a FRESH FOCAS driver after a redeploy and asserts the ack survives. MAJOR-2: a failed FOCAS alarm read annotates each subscribed condition BadNoCommunication once per outage (#626 quality-only path) with one Warning (MINOR-6), lifted to Good on recovery; failed alarm reads degrade driver health with LastSuccessfulRead frozen (successful ones advance it), so an alarm-only driver trips the #527 comms-loss watchdog. MINOR-3 CLAUDE.md #630 bullet; MINOR-4 split line; MINOR-5 a non-empty cnc_rdalmmsg2 payload that fits neither stride throws; MINOR-7 value-tag + parsed-address tables are built and swapped, never cleared in place under the retained poll engine. Docs corrected (FOCAS.md, AlarmTracking.md, CLAUDE.md). Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
This commit is contained in:
@@ -57,6 +57,22 @@ internal sealed class FocasAlarmProjection : IAsyncDisposable
|
||||
/// <summary>Devices whose last read came back at the per-read cap. Guarded by <see cref="_alarmLock"/>.</summary>
|
||||
private readonly HashSet<string> _truncationWarned = new(StringComparer.OrdinalIgnoreCase);
|
||||
|
||||
/// <summary>Devices whose alarm read is currently failing (one Warning per episode). Guarded by <see cref="_alarmLock"/>.</summary>
|
||||
private readonly HashSet<string> _failingDevices = new(StringComparer.OrdinalIgnoreCase);
|
||||
|
||||
/// <summary>
|
||||
/// ConditionIds this projection has annotated <c>BadNoCommunication</c> and not yet lifted. Guarded by
|
||||
/// <see cref="_alarmLock"/>. Kept apart from <see cref="_told"/>: a quality annotation never touches a
|
||||
/// condition's Active/Acked state.
|
||||
/// </summary>
|
||||
private readonly HashSet<string> _qualityBadTold = new(StringComparer.Ordinal);
|
||||
|
||||
/// <summary>Canonical <c>Opc.Ua.StatusCodes.Good</c>.</summary>
|
||||
private const uint QualityGood = 0x00000000u;
|
||||
|
||||
/// <summary>Canonical <c>Opc.Ua.StatusCodes.BadNoCommunication</c>.</summary>
|
||||
private const uint QualityBadNoCommunication = 0x80310000u;
|
||||
|
||||
/// <summary>Serializes loop start/stop.</summary>
|
||||
private readonly SemaphoreSlim _loopGate = new(1, 1);
|
||||
|
||||
@@ -95,7 +111,11 @@ internal sealed class FocasAlarmProjection : IAsyncDisposable
|
||||
lock (_alarmLock)
|
||||
{
|
||||
// Forget only the conditions that LEFT the set (#641) — the SAME set (a reconnect) prunes nothing.
|
||||
foreach (var gone in _told.Keys.Where(k => !refs.Contains(k)).ToList()) _told.Remove(gone); Volatile.Write(ref _current, sub);
|
||||
foreach (var gone in _told.Keys.Where(k => !refs.Contains(k)).ToList()) _told.Remove(gone);
|
||||
// A (re)subscribe follows a reconnect, where the host re-annotates every condition Good (#477); forget
|
||||
// which conditions this projection marked Bad, so a still-failing device re-asserts its Bad.
|
||||
_qualityBadTold.Clear();
|
||||
Volatile.Write(ref _current, sub);
|
||||
}
|
||||
await RestartLoopAsync().ConfigureAwait(false);
|
||||
return sub.Handle;
|
||||
@@ -225,10 +245,14 @@ internal sealed class FocasAlarmProjection : IAsyncDisposable
|
||||
catch (OperationCanceledException) when (ct.IsCancellationRequested) { throw; }
|
||||
catch (Exception ex)
|
||||
{
|
||||
// Not "no alarms": keep every condition on this device exactly as the server was last told.
|
||||
_logger.LogDebug(ex, "FOCAS alarm read failed for {Host}; its conditions keep their state", host);
|
||||
// Not "no alarms": keep every condition on this device exactly as the server was last told, but say
|
||||
// its source is unreachable — and let the failure reach driver health (an alarm-only driver has no
|
||||
// other read to trip the comms-loss watchdog with).
|
||||
_driver.NoteAlarmReadFailed(host, ex);
|
||||
TickFailed(sub, host, tags, ex);
|
||||
continue;
|
||||
}
|
||||
_driver.NoteAlarmReadSucceeded();
|
||||
Tick(sub, host, alarms, tags);
|
||||
}
|
||||
}
|
||||
@@ -266,24 +290,92 @@ internal sealed class FocasAlarmProjection : IAsyncDisposable
|
||||
var handlers = _driver.AlarmHandlers;
|
||||
if (handlers is null) return;
|
||||
|
||||
if (_failingDevices.Remove(deviceHostAddress))
|
||||
_logger.LogInformation("FOCAS alarm read for {Host} recovered", deviceHostAddress);
|
||||
|
||||
foreach (var tag in deviceTags.Where(t => sub.References.Contains(t.RawPath)))
|
||||
{
|
||||
// Lift a Bad this projection put there BEFORE the normal diff, so a recovery that also changed the
|
||||
// alarm state (cleared during the outage) lands as Good then Clear.
|
||||
if (_qualityBadTold.Remove(tag.RawPath))
|
||||
Deliver(handlers, QualityOnly(tag, sub.Handle, QualityGood, now), tag.RawPath);
|
||||
|
||||
var view = FocasAlarmMatcher.Evaluate(tag.Selector, alarms, deviceSelectors, truncated);
|
||||
_told.TryGetValue(tag.RawPath, out var told);
|
||||
var (evt, nowTold) = FocasAlarmConditionMapper.Transition(told, view, tag, sub.Handle, now);
|
||||
_told[tag.RawPath] = nowTold;
|
||||
if (evt is null) continue;
|
||||
Deliver(handlers, evt, tag.RawPath);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
foreach (var registration in handlers.GetInvocationList())
|
||||
{
|
||||
try { ((EventHandler<AlarmEventArgs>)registration).Invoke(_driver, evt); }
|
||||
catch (Exception ex)
|
||||
{
|
||||
_logger.LogWarning(ex,
|
||||
"FOCAS driver caught a fault from an alarm subscriber for {ConditionId}; delivery continues.",
|
||||
tag.RawPath);
|
||||
}
|
||||
}
|
||||
/// <summary>
|
||||
/// A FAILED read of <paramref name="deviceHostAddress"/> (Gitea #647 review): conditions keep their state, but
|
||||
/// each subscribed one is annotated <c>BadNoCommunication</c> once per outage through the #626 quality-only
|
||||
/// path (no Active/Acked change, no <c>/alerts</c> row), and the first failure of the episode logs one
|
||||
/// Warning. The next successful read lifts the Bad in <see cref="Tick"/>.
|
||||
/// </summary>
|
||||
/// <param name="sub">The subscription the read was taken for; a superseded one emits nothing.</param>
|
||||
/// <param name="deviceHostAddress">The device whose read failed.</param>
|
||||
/// <param name="tags">The driver's alarm-tag table (RawPath → tag).</param>
|
||||
/// <param name="error">Why the read failed.</param>
|
||||
internal void TickFailed(
|
||||
Subscription sub, string deviceHostAddress, IReadOnlyDictionary<string, FocasAlarmTag> tags, Exception error)
|
||||
{
|
||||
var now = DateTime.UtcNow;
|
||||
lock (_alarmLock)
|
||||
{
|
||||
if (!ReferenceEquals(Volatile.Read(ref _current), sub)) return;
|
||||
|
||||
if (_failingDevices.Add(deviceHostAddress))
|
||||
_logger.LogWarning(error,
|
||||
"FOCAS alarm read (cnc_rdalmmsg2) failed for {Host}; its alarm conditions keep their state and are " +
|
||||
"marked BadNoCommunication until a read succeeds", deviceHostAddress);
|
||||
else
|
||||
_logger.LogDebug(error, "FOCAS alarm read for {Host} still failing", deviceHostAddress);
|
||||
|
||||
// As for transitions: with nobody listening, record nothing, so the next failure tells it.
|
||||
var handlers = _driver.AlarmHandlers;
|
||||
if (handlers is null) return;
|
||||
|
||||
foreach (var tag in tags.Values.Where(t =>
|
||||
string.Equals(t.DeviceHostAddress, deviceHostAddress, StringComparison.OrdinalIgnoreCase)
|
||||
&& sub.References.Contains(t.RawPath)))
|
||||
{
|
||||
if (!_qualityBadTold.Add(tag.RawPath)) continue;
|
||||
Deliver(handlers, QualityOnly(tag, sub.Handle, QualityBadNoCommunication, now), tag.RawPath);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>A quality-only annotation (#626): <see cref="AlarmTransitionKind.Unspecified"/> + a status code.</summary>
|
||||
private AlarmEventArgs QualityOnly(FocasAlarmTag tag, IAlarmSubscriptionHandle handle, uint quality, DateTime now)
|
||||
{
|
||||
_told.TryGetValue(tag.RawPath, out var told);
|
||||
return new AlarmEventArgs(handle,
|
||||
SourceNodeId: tag.DeviceHostAddress,
|
||||
ConditionId: tag.RawPath,
|
||||
AlarmType: told?.Winner is { } w ? FocasAlarmConditionMapper.TypeLabel(w.Type) : "CncAlarm",
|
||||
Message: told?.Message ?? "",
|
||||
Severity: told?.Severity ?? AlarmSeverity.Low,
|
||||
SourceTimestampUtc: now,
|
||||
Kind: AlarmTransitionKind.Unspecified,
|
||||
OpcUaSeverity: told?.OpcUaSeverity,
|
||||
QualityStatusCode: quality);
|
||||
}
|
||||
|
||||
/// <summary>Invokes every handler, isolating a faulting one. Caller holds the lock.</summary>
|
||||
private void Deliver(EventHandler<AlarmEventArgs> handlers, AlarmEventArgs evt, string conditionId)
|
||||
{
|
||||
foreach (var registration in handlers.GetInvocationList())
|
||||
{
|
||||
try { ((EventHandler<AlarmEventArgs>)registration).Invoke(_driver, evt); }
|
||||
catch (Exception ex)
|
||||
{
|
||||
_logger.LogWarning(ex,
|
||||
"FOCAS driver caught a fault from an alarm subscriber for {ConditionId}; delivery continues.",
|
||||
conditionId);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue