fix(alarms): #647 review — Raise on an active condition is a re-statement; FOCAS outage quality + health
MAJOR-1: a deploy that changes a driver's config respawns it, and the fresh instance's empty told record re-sent Raise for every still-active alarm, un-acking acknowledged conditions and writing a duplicate "Activated" alerts row. NativeAlarmProjector now treats Raise on an already-active condition as a re-statement (keeps Acked; ForwardNativeAlarm skips the alerts row); only Retrigger (or inactive->active) un-acks. Sources whose upstream ack state is authoritative send Retrigger for an unacked re-statement: OpcUaClient on first sight (no prior told), Galaxy for an unacked active snapshot entry. Runtime E2E drives a FRESH FOCAS driver after a redeploy and asserts the ack survives. MAJOR-2: a failed FOCAS alarm read annotates each subscribed condition BadNoCommunication once per outage (#626 quality-only path) with one Warning (MINOR-6), lifted to Good on recovery; failed alarm reads degrade driver health with LastSuccessfulRead frozen (successful ones advance it), so an alarm-only driver trips the #527 comms-loss watchdog. MINOR-3 CLAUDE.md #630 bullet; MINOR-4 split line; MINOR-5 a non-empty cnc_rdalmmsg2 payload that fits neither stride throws; MINOR-7 value-tag + parsed-address tables are built and swapped, never cleared in place under the retained poll engine. Docs corrected (FOCAS.md, AlarmTracking.md, CLAUDE.md). Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
This commit is contained in:
@@ -57,6 +57,22 @@ internal sealed class FocasAlarmProjection : IAsyncDisposable
|
||||
/// <summary>Devices whose last read came back at the per-read cap. Guarded by <see cref="_alarmLock"/>.</summary>
|
||||
private readonly HashSet<string> _truncationWarned = new(StringComparer.OrdinalIgnoreCase);
|
||||
|
||||
/// <summary>Devices whose alarm read is currently failing (one Warning per episode). Guarded by <see cref="_alarmLock"/>.</summary>
|
||||
private readonly HashSet<string> _failingDevices = new(StringComparer.OrdinalIgnoreCase);
|
||||
|
||||
/// <summary>
|
||||
/// ConditionIds this projection has annotated <c>BadNoCommunication</c> and not yet lifted. Guarded by
|
||||
/// <see cref="_alarmLock"/>. Kept apart from <see cref="_told"/>: a quality annotation never touches a
|
||||
/// condition's Active/Acked state.
|
||||
/// </summary>
|
||||
private readonly HashSet<string> _qualityBadTold = new(StringComparer.Ordinal);
|
||||
|
||||
/// <summary>Canonical <c>Opc.Ua.StatusCodes.Good</c>.</summary>
|
||||
private const uint QualityGood = 0x00000000u;
|
||||
|
||||
/// <summary>Canonical <c>Opc.Ua.StatusCodes.BadNoCommunication</c>.</summary>
|
||||
private const uint QualityBadNoCommunication = 0x80310000u;
|
||||
|
||||
/// <summary>Serializes loop start/stop.</summary>
|
||||
private readonly SemaphoreSlim _loopGate = new(1, 1);
|
||||
|
||||
@@ -95,7 +111,11 @@ internal sealed class FocasAlarmProjection : IAsyncDisposable
|
||||
lock (_alarmLock)
|
||||
{
|
||||
// Forget only the conditions that LEFT the set (#641) — the SAME set (a reconnect) prunes nothing.
|
||||
foreach (var gone in _told.Keys.Where(k => !refs.Contains(k)).ToList()) _told.Remove(gone); Volatile.Write(ref _current, sub);
|
||||
foreach (var gone in _told.Keys.Where(k => !refs.Contains(k)).ToList()) _told.Remove(gone);
|
||||
// A (re)subscribe follows a reconnect, where the host re-annotates every condition Good (#477); forget
|
||||
// which conditions this projection marked Bad, so a still-failing device re-asserts its Bad.
|
||||
_qualityBadTold.Clear();
|
||||
Volatile.Write(ref _current, sub);
|
||||
}
|
||||
await RestartLoopAsync().ConfigureAwait(false);
|
||||
return sub.Handle;
|
||||
@@ -225,10 +245,14 @@ internal sealed class FocasAlarmProjection : IAsyncDisposable
|
||||
catch (OperationCanceledException) when (ct.IsCancellationRequested) { throw; }
|
||||
catch (Exception ex)
|
||||
{
|
||||
// Not "no alarms": keep every condition on this device exactly as the server was last told.
|
||||
_logger.LogDebug(ex, "FOCAS alarm read failed for {Host}; its conditions keep their state", host);
|
||||
// Not "no alarms": keep every condition on this device exactly as the server was last told, but say
|
||||
// its source is unreachable — and let the failure reach driver health (an alarm-only driver has no
|
||||
// other read to trip the comms-loss watchdog with).
|
||||
_driver.NoteAlarmReadFailed(host, ex);
|
||||
TickFailed(sub, host, tags, ex);
|
||||
continue;
|
||||
}
|
||||
_driver.NoteAlarmReadSucceeded();
|
||||
Tick(sub, host, alarms, tags);
|
||||
}
|
||||
}
|
||||
@@ -266,24 +290,92 @@ internal sealed class FocasAlarmProjection : IAsyncDisposable
|
||||
var handlers = _driver.AlarmHandlers;
|
||||
if (handlers is null) return;
|
||||
|
||||
if (_failingDevices.Remove(deviceHostAddress))
|
||||
_logger.LogInformation("FOCAS alarm read for {Host} recovered", deviceHostAddress);
|
||||
|
||||
foreach (var tag in deviceTags.Where(t => sub.References.Contains(t.RawPath)))
|
||||
{
|
||||
// Lift a Bad this projection put there BEFORE the normal diff, so a recovery that also changed the
|
||||
// alarm state (cleared during the outage) lands as Good then Clear.
|
||||
if (_qualityBadTold.Remove(tag.RawPath))
|
||||
Deliver(handlers, QualityOnly(tag, sub.Handle, QualityGood, now), tag.RawPath);
|
||||
|
||||
var view = FocasAlarmMatcher.Evaluate(tag.Selector, alarms, deviceSelectors, truncated);
|
||||
_told.TryGetValue(tag.RawPath, out var told);
|
||||
var (evt, nowTold) = FocasAlarmConditionMapper.Transition(told, view, tag, sub.Handle, now);
|
||||
_told[tag.RawPath] = nowTold;
|
||||
if (evt is null) continue;
|
||||
Deliver(handlers, evt, tag.RawPath);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
foreach (var registration in handlers.GetInvocationList())
|
||||
{
|
||||
try { ((EventHandler<AlarmEventArgs>)registration).Invoke(_driver, evt); }
|
||||
catch (Exception ex)
|
||||
{
|
||||
_logger.LogWarning(ex,
|
||||
"FOCAS driver caught a fault from an alarm subscriber for {ConditionId}; delivery continues.",
|
||||
tag.RawPath);
|
||||
}
|
||||
}
|
||||
/// <summary>
|
||||
/// A FAILED read of <paramref name="deviceHostAddress"/> (Gitea #647 review): conditions keep their state, but
|
||||
/// each subscribed one is annotated <c>BadNoCommunication</c> once per outage through the #626 quality-only
|
||||
/// path (no Active/Acked change, no <c>/alerts</c> row), and the first failure of the episode logs one
|
||||
/// Warning. The next successful read lifts the Bad in <see cref="Tick"/>.
|
||||
/// </summary>
|
||||
/// <param name="sub">The subscription the read was taken for; a superseded one emits nothing.</param>
|
||||
/// <param name="deviceHostAddress">The device whose read failed.</param>
|
||||
/// <param name="tags">The driver's alarm-tag table (RawPath → tag).</param>
|
||||
/// <param name="error">Why the read failed.</param>
|
||||
internal void TickFailed(
|
||||
Subscription sub, string deviceHostAddress, IReadOnlyDictionary<string, FocasAlarmTag> tags, Exception error)
|
||||
{
|
||||
var now = DateTime.UtcNow;
|
||||
lock (_alarmLock)
|
||||
{
|
||||
if (!ReferenceEquals(Volatile.Read(ref _current), sub)) return;
|
||||
|
||||
if (_failingDevices.Add(deviceHostAddress))
|
||||
_logger.LogWarning(error,
|
||||
"FOCAS alarm read (cnc_rdalmmsg2) failed for {Host}; its alarm conditions keep their state and are " +
|
||||
"marked BadNoCommunication until a read succeeds", deviceHostAddress);
|
||||
else
|
||||
_logger.LogDebug(error, "FOCAS alarm read for {Host} still failing", deviceHostAddress);
|
||||
|
||||
// As for transitions: with nobody listening, record nothing, so the next failure tells it.
|
||||
var handlers = _driver.AlarmHandlers;
|
||||
if (handlers is null) return;
|
||||
|
||||
foreach (var tag in tags.Values.Where(t =>
|
||||
string.Equals(t.DeviceHostAddress, deviceHostAddress, StringComparison.OrdinalIgnoreCase)
|
||||
&& sub.References.Contains(t.RawPath)))
|
||||
{
|
||||
if (!_qualityBadTold.Add(tag.RawPath)) continue;
|
||||
Deliver(handlers, QualityOnly(tag, sub.Handle, QualityBadNoCommunication, now), tag.RawPath);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>A quality-only annotation (#626): <see cref="AlarmTransitionKind.Unspecified"/> + a status code.</summary>
|
||||
private AlarmEventArgs QualityOnly(FocasAlarmTag tag, IAlarmSubscriptionHandle handle, uint quality, DateTime now)
|
||||
{
|
||||
_told.TryGetValue(tag.RawPath, out var told);
|
||||
return new AlarmEventArgs(handle,
|
||||
SourceNodeId: tag.DeviceHostAddress,
|
||||
ConditionId: tag.RawPath,
|
||||
AlarmType: told?.Winner is { } w ? FocasAlarmConditionMapper.TypeLabel(w.Type) : "CncAlarm",
|
||||
Message: told?.Message ?? "",
|
||||
Severity: told?.Severity ?? AlarmSeverity.Low,
|
||||
SourceTimestampUtc: now,
|
||||
Kind: AlarmTransitionKind.Unspecified,
|
||||
OpcUaSeverity: told?.OpcUaSeverity,
|
||||
QualityStatusCode: quality);
|
||||
}
|
||||
|
||||
/// <summary>Invokes every handler, isolating a faulting one. Caller holds the lock.</summary>
|
||||
private void Deliver(EventHandler<AlarmEventArgs> handlers, AlarmEventArgs evt, string conditionId)
|
||||
{
|
||||
foreach (var registration in handlers.GetInvocationList())
|
||||
{
|
||||
try { ((EventHandler<AlarmEventArgs>)registration).Invoke(_driver, evt); }
|
||||
catch (Exception ex)
|
||||
{
|
||||
_logger.LogWarning(ex,
|
||||
"FOCAS driver caught a fault from an alarm subscriber for {ConditionId}; delivery continues.",
|
||||
conditionId);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@@ -47,7 +47,9 @@ public sealed class FocasDriver : IDriver, IReadable, IWritable, ITagDiscovery,
|
||||
private readonly Dictionary<string, DeviceState> _devices = new(StringComparer.OrdinalIgnoreCase);
|
||||
// v3: RawPath → definition, case-sensitive ordinal. Built in InitializeAsync from _options.RawTags
|
||||
// via the pure FocasTagDefinitionFactory mapper (the reference is always a RawPath).
|
||||
private readonly Dictionary<string, FocasTagDefinition> _tagsByRawPath = new(StringComparer.Ordinal);
|
||||
// Built whole in InitializeAsync and SWAPPED in (Gitea #647 review): the #630-retained poll engine keeps calling
|
||||
// ReadAsync during a re-initialise, and a table cleared and refilled in place reads BadNodeIdUnknown in between.
|
||||
private Dictionary<string, FocasTagDefinition> _tagsByRawPath = new(StringComparer.Ordinal);
|
||||
// Resolves a read/write fullReference (always a RawPath in v3) to a tag definition by a single
|
||||
// authored-table hit. A miss is a miss — the driver surfaces BadNodeIdUnknown, never a blob-parse.
|
||||
private readonly EquipmentTagRefResolver<FocasTagDefinition> _resolver;
|
||||
@@ -56,7 +58,7 @@ public sealed class FocasDriver : IDriver, IReadable, IWritable, ITagDiscovery,
|
||||
// call. ConcurrentDictionary is required because the poll loop
|
||||
// (ReadAsync) and the host write thread (WriteAsync) both mutate this cache when resolver-
|
||||
// produced equipment tags are encountered for the first time.
|
||||
private readonly ConcurrentDictionary<string, FocasAddress> _parsedAddressesByTagName =
|
||||
private ConcurrentDictionary<string, FocasAddress> _parsedAddressesByTagName =
|
||||
new(StringComparer.OrdinalIgnoreCase);
|
||||
/// <summary>
|
||||
/// Whether this driver instance runs its per-device fixed-tree poll loop, and therefore
|
||||
@@ -128,7 +130,7 @@ public sealed class FocasDriver : IDriver, IReadable, IWritable, ITagDiscovery,
|
||||
_logger = logger ?? NullLogger<FocasDriver>.Instance;
|
||||
_alarmProjection = new FocasAlarmProjection(this, _logger);
|
||||
_resolver = new EquipmentTagRefResolver<FocasTagDefinition>(
|
||||
r => _tagsByRawPath.TryGetValue(r, out var t) ? t : null);
|
||||
r => Volatile.Read(ref _tagsByRawPath).TryGetValue(r, out var t) ? t : null);
|
||||
_poll = new PollGroupEngine(
|
||||
reader: ReadAsync,
|
||||
onChange: (handle, tagRef, snapshot) =>
|
||||
@@ -234,8 +236,9 @@ public sealed class FocasDriver : IDriver, IReadable, IWritable, ITagDiscovery,
|
||||
_skippedTags.BeginRebuild(_options.RawTags.Count);
|
||||
// A re-initialise without teardown (#630) rebuilds the tables from scratch: a tag the new config
|
||||
// removed — or moved between the value and alarm tables (#647) — must not survive in the old one.
|
||||
_tagsByRawPath.Clear();
|
||||
_parsedAddressesByTagName.Clear();
|
||||
// Built into fresh tables and swapped in below, never cleared in place under a live reader.
|
||||
var tagsByRawPath = new Dictionary<string, FocasTagDefinition>(StringComparer.Ordinal);
|
||||
var parsedAddresses = new ConcurrentDictionary<string, FocasAddress>(StringComparer.OrdinalIgnoreCase);
|
||||
var alarmTags = new Dictionary<string, FocasAlarmTag>(StringComparer.Ordinal);
|
||||
foreach (var entry in _options.RawTags)
|
||||
{
|
||||
@@ -298,7 +301,7 @@ public sealed class FocasDriver : IDriver, IReadable, IWritable, ITagDiscovery,
|
||||
entry.RawPath, why, _driverInstanceId);
|
||||
continue;
|
||||
}
|
||||
_tagsByRawPath[entry.RawPath] = def with
|
||||
tagsByRawPath[entry.RawPath] = def with
|
||||
{
|
||||
DeviceHostAddress = deviceHost,
|
||||
WriteIdempotent = entry.WriteIdempotent,
|
||||
@@ -306,12 +309,14 @@ public sealed class FocasDriver : IDriver, IReadable, IWritable, ITagDiscovery,
|
||||
// Cache the parsed FocasAddress so ReadAsync / WriteAsync don't re-parse on every
|
||||
// hot-path call. The address string has already been validated by FocasAddress.TryParse
|
||||
// above; reusing the parsed record avoids per-tick allocs on subscription pollers.
|
||||
_parsedAddressesByTagName[entry.RawPath] = parsed;
|
||||
parsedAddresses[entry.RawPath] = parsed;
|
||||
}
|
||||
// Publish the skip tally only once the whole table is built. An unknown-device throw above
|
||||
// leaves the previous snapshot standing rather than a truncated one that would read as
|
||||
// "we now skip fewer tags".
|
||||
_skippedTags.Commit();
|
||||
Volatile.Write(ref _parsedAddressesByTagName, parsedAddresses);
|
||||
Volatile.Write(ref _tagsByRawPath, tagsByRawPath);
|
||||
Volatile.Write(ref _alarmTags, alarmTags);
|
||||
|
||||
if (_options.Probe.Enabled)
|
||||
@@ -465,7 +470,7 @@ public sealed class FocasDriver : IDriver, IReadable, IWritable, ITagDiscovery,
|
||||
state.DisposeClient();
|
||||
}
|
||||
_devices.Clear();
|
||||
_tagsByRawPath.Clear();
|
||||
Volatile.Write(ref _tagsByRawPath, new Dictionary<string, FocasTagDefinition>(StringComparer.Ordinal));
|
||||
Volatile.Write(ref _alarmTags, new Dictionary<string, FocasAlarmTag>(StringComparer.Ordinal));
|
||||
_resolver.Clear(); // no-op in v3 (the resolver reads the live table by closure); kept for symmetry
|
||||
_parsedAddressesByTagName.Clear();
|
||||
@@ -1693,6 +1698,35 @@ public sealed class FocasDriver : IDriver, IReadable, IWritable, ITagDiscovery,
|
||||
/// <summary>Gets the alarm poll cadence — one <c>cnc_rdalmmsg2</c> per alarm-owning device per tick.</summary>
|
||||
internal TimeSpan AlarmPollInterval => _options.AlarmProjection.PollInterval;
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// A successful alarm read is a successful read (Gitea #647 review): it advances
|
||||
/// <see cref="DriverHealth.LastSuccessfulRead"/> exactly as a Good value read does, so an alarm-only driver's
|
||||
/// health tracks its CNC. Never lifts a <see cref="DriverState.Faulted"/> (a config-level signal).
|
||||
/// </summary>
|
||||
internal void NoteAlarmReadSucceeded()
|
||||
{
|
||||
var current = Volatile.Read(ref _health);
|
||||
if (current.State != DriverState.Faulted)
|
||||
Volatile.Write(ref _health, new DriverHealth(DriverState.Healthy, DateTime.UtcNow, null));
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// A failed alarm read degrades driver health, PRESERVING <see cref="DriverHealth.LastSuccessfulRead"/> — the
|
||||
/// conjunction the comms-loss watchdog (#527) trips on. Without it a driver whose only tags are <c>ALARM:</c>
|
||||
/// tags stayed Healthy through a total outage, the watchdog never fired, and the host's #477
|
||||
/// <c>BadNoCommunication</c> annotation never ran (Gitea #647 review).
|
||||
/// </summary>
|
||||
/// <param name="hostAddress">The device whose alarm read failed.</param>
|
||||
/// <param name="error">Why.</param>
|
||||
internal void NoteAlarmReadFailed(string hostAddress, Exception error)
|
||||
{
|
||||
var current = Volatile.Read(ref _health);
|
||||
if (current.State != DriverState.Faulted)
|
||||
Volatile.Write(ref _health, new DriverHealth(DriverState.Degraded, current.LastSuccessfulRead,
|
||||
$"FOCAS alarm read failed for {hostAddress}: {error.Message}"));
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Reads one device's active-alarm list. <b>Throws on any failure</b> — an unknown device, a connect that
|
||||
/// fails, a read the CNC refuses — because the projection must never mistake a failed read for an empty
|
||||
|
||||
@@ -1101,10 +1101,24 @@ public sealed class FocasWireClient : IAsyncDisposable, IDisposable
|
||||
return new WireProgramName(name, number);
|
||||
}
|
||||
|
||||
private static IReadOnlyList<WireAlarm> ParseAlarms(byte[] payload, short count)
|
||||
=> payload.Length % 76 == 0
|
||||
? ParseVendorAlarms(payload, count)
|
||||
: ParseLegacyWireAlarms(payload, count);
|
||||
/// <summary>
|
||||
/// Decode a <c>cnc_rdalmmsg2</c> payload: the 76-byte vendor stride, else the 80-byte legacy one. An empty
|
||||
/// payload is "no alarms active". A non-empty payload that fits NEITHER stride is malformed and throws
|
||||
/// (Gitea #647 review): it used to fall into the legacy parser, decode zero records, and so read as "no
|
||||
/// alarms" — a mass Clear of every condition on the device, then an un-acknowledged re-raise next poll.
|
||||
/// </summary>
|
||||
/// <param name="payload">The reply payload.</param>
|
||||
/// <param name="count">The requested record count.</param>
|
||||
/// <returns>The decoded alarms.</returns>
|
||||
/// <exception cref="FocasWireException">The payload length matches neither record layout.</exception>
|
||||
internal static IReadOnlyList<WireAlarm> ParseAlarms(byte[] payload, short count)
|
||||
{
|
||||
if (payload.Length % 76 == 0) return ParseVendorAlarms(payload, count);
|
||||
if (payload.Length % 80 == 0) return ParseLegacyWireAlarms(payload, count);
|
||||
throw new FocasWireException(
|
||||
$"cnc_rdalmmsg2 returned a {payload.Length}-byte payload, which fits neither the 76- nor the 80-byte " +
|
||||
"record layout; refusing to read it as an empty alarm list.", rc: null);
|
||||
}
|
||||
|
||||
private static IReadOnlyList<WireAlarm> ParseVendorAlarms(byte[] payload, short count)
|
||||
{
|
||||
|
||||
@@ -171,14 +171,18 @@ internal sealed class GatewayGalaxyAlarmFeed : IGalaxyAlarmFeed
|
||||
/// Decode one entry of the initial active-alarm snapshot. Each currently-active
|
||||
/// alarm is surfaced as a transition so the OPC UA Part 9 condition layer sees
|
||||
/// the alarm's present state on (re)connect: an unacknowledged active alarm as
|
||||
/// a <see cref="GalaxyAlarmTransitionKind.Raise"/>, an acknowledged one as a
|
||||
/// a <see cref="GalaxyAlarmTransitionKind.Retrigger"/>, an acknowledged one as a
|
||||
/// <see cref="GalaxyAlarmTransitionKind.Acknowledge"/>.
|
||||
/// <para>Retrigger, not Raise (Gitea #647 review): the host treats a Raise on a condition it already
|
||||
/// shows Active as a re-statement that KEEPS the acknowledgement. A snapshot re-states upstream state and
|
||||
/// the upstream's ack state is authoritative, so an unacked entry must un-ack a host condition still
|
||||
/// holding an ack from before the reconnect.</para>
|
||||
/// </summary>
|
||||
private void DispatchSnapshotEntry(ActiveAlarmSnapshot snapshot)
|
||||
{
|
||||
var kind = snapshot.CurrentState switch
|
||||
{
|
||||
AlarmConditionState.Active => GalaxyAlarmTransitionKind.Raise,
|
||||
AlarmConditionState.Active => GalaxyAlarmTransitionKind.Retrigger,
|
||||
AlarmConditionState.ActiveAcked => GalaxyAlarmTransitionKind.Acknowledge,
|
||||
AlarmConditionState.Inactive => GalaxyAlarmTransitionKind.Clear,
|
||||
_ => GalaxyAlarmTransitionKind.Unspecified,
|
||||
|
||||
@@ -1982,12 +1982,11 @@ public sealed class OpcUaClientDriver : IDriver, ITagDiscovery, IReadable, IWrit
|
||||
|
||||
// Fresh prior = the host projector's own default (inactive, acked).
|
||||
var told = new AlarmToldState(target.Active, target.Acked, e.Message, e.OpcUaSeverity);
|
||||
var prior = _alarmStateByRawPath.TryGetValue(e.ConditionId, out var p)
|
||||
? p
|
||||
: new AlarmToldState(false, true, null, null);
|
||||
var priorKnown = _alarmStateByRawPath.TryGetValue(e.ConditionId, out var p);
|
||||
var prior = priorKnown ? p! : new AlarmToldState(false, true, null, null);
|
||||
_alarmStateByRawPath[e.ConditionId] = told;
|
||||
|
||||
var kinds = AlarmTransitions((prior.Active, prior.Acked), target);
|
||||
var kinds = AlarmTransitions((prior.Active, prior.Acked), target, priorKnown);
|
||||
if (kinds.Count == 0)
|
||||
{
|
||||
// Same state: a message/severity change still reaches the host; an identical copy does not.
|
||||
@@ -2106,18 +2105,34 @@ public sealed class OpcUaClientDriver : IDriver, ITagDiscovery, IReadable, IWrit
|
||||
|
||||
/// <summary>
|
||||
/// #619 review — the <see cref="AlarmTransitionKind"/> sequence that moves the host's
|
||||
/// <c>NativeAlarmProjector</c> (which knows only kinds: Raise ⇒ active+unacked, Acknowledge ⇒ acked,
|
||||
/// <c>NativeAlarmProjector</c> (which knows only kinds: Raise ⇒ active+unacked — or, on an already-active condition, a re-statement keeping the ack (#647) — Acknowledge ⇒ acked,
|
||||
/// Clear ⇒ inactive keeping acked) from <paramref name="prior"/> to <paramref name="target"/>. A single
|
||||
/// upstream event can need two (an alarm that went active and was acknowledged between two notifications).
|
||||
/// No state change ⇒ empty (the caller decides whether a message/severity change warrants an Unspecified).
|
||||
/// </summary>
|
||||
/// <param name="prior">The state last told to the host.</param>
|
||||
/// <param name="target">The upstream event's ActiveState/Id + AckedState/Id.</param>
|
||||
/// <param name="priorKnown">
|
||||
/// False when this driver instance has told the host nothing about the condition yet (first sight after a
|
||||
/// start or a deploy respawn), so <paramref name="prior"/> is only the projector's default. Gitea #647 review:
|
||||
/// the host now treats a Raise on an already-active condition as a re-statement that KEEPS its ack, so an
|
||||
/// upstream that says <i>unacknowledged</i> must then be told with <see cref="AlarmTransitionKind.Retrigger"/>
|
||||
/// — the upstream's ack state is authoritative, and the host may be holding an ack from before the respawn.
|
||||
/// </param>
|
||||
/// <returns>The kinds to emit, in order.</returns>
|
||||
internal static IReadOnlyList<AlarmTransitionKind> AlarmTransitions(
|
||||
(bool Active, bool Acked) prior, (bool Active, bool Acked) target)
|
||||
(bool Active, bool Acked) prior, (bool Active, bool Acked) target, bool priorKnown = true)
|
||||
{
|
||||
if (prior == target) return [];
|
||||
var kinds = Transitions(prior, target);
|
||||
return priorKnown || target.Acked
|
||||
? kinds
|
||||
: [.. kinds.Select(k => k == AlarmTransitionKind.Raise ? AlarmTransitionKind.Retrigger : k)];
|
||||
}
|
||||
|
||||
private static IReadOnlyList<AlarmTransitionKind> Transitions(
|
||||
(bool Active, bool Acked) prior, (bool Active, bool Acked) target)
|
||||
{
|
||||
return target switch
|
||||
{
|
||||
// Active+unacked: a fresh raise, or a re-arm of an active-acked condition.
|
||||
|
||||
@@ -1877,12 +1877,14 @@ public sealed class DriverHostActor : ReceiveActor, IWithTimers, IWithUnboundedS
|
||||
foreach (var n in nodeIds)
|
||||
{
|
||||
var nodeId = n.NodeId;
|
||||
var snapshot = _nativeAlarmProjector.Project(nodeId, msg.Args);
|
||||
var snapshot = _nativeAlarmProjector.Project(nodeId, msg.Args, out var restatement);
|
||||
_opcUaPublishActor.Tell(new ZB.MOM.WW.OtOpcUa.Runtime.OpcUa.OpcUaPublishActor.AlarmStateUpdate(
|
||||
nodeId, snapshot, msg.Args.SourceTimestampUtc, n.Realm));
|
||||
|
||||
// Only the Primary publishes the cluster-wide alerts transition (see the gate above).
|
||||
if (!serviceAlertsAsPrimary) continue;
|
||||
// Only the Primary publishes the cluster-wide alerts transition (see the gate above). A re-statement
|
||||
// (Gitea #647 review: a Raise on an already-active condition, sent by a driver a deploy respawned) is
|
||||
// not a transition — the condition was already Active, so a second "Activated" row would be a duplicate.
|
||||
if (!serviceAlertsAsPrimary || restatement) continue;
|
||||
|
||||
var meta = _alarmMetaByNodeId.TryGetValue(nodeId, out var m)
|
||||
? m : (EquipmentId: nodeId, Name: nodeId, AlarmType: "AlarmCondition", HistorizeToAveva: (bool?)null,
|
||||
|
||||
@@ -18,13 +18,29 @@ public sealed class NativeAlarmProjector
|
||||
/// <param name="nodeId">The materialised condition node's id (the projection's state key).</param>
|
||||
/// <param name="e">The native alarm transition.</param>
|
||||
/// <returns>The full Part 9 condition snapshot to write to the node.</returns>
|
||||
public AlarmConditionSnapshot Project(string nodeId, AlarmEventArgs e)
|
||||
public AlarmConditionSnapshot Project(string nodeId, AlarmEventArgs e) => Project(nodeId, e, out _);
|
||||
|
||||
/// <summary>
|
||||
/// Project an alarm transition, reporting whether it was a <b>re-statement</b> (Gitea #647 review): a
|
||||
/// <see cref="AlarmTransitionKind.Raise"/> on a condition already projected Active. That is what a driver
|
||||
/// whose told-record died with its instance sends after a deploy respawns it — the alarm it re-reads is the
|
||||
/// one the server already shows, so the acknowledgement is KEPT and the host writes no second "Activated"
|
||||
/// row. Only <see cref="AlarmTransitionKind.Retrigger"/> (or inactive → active) un-acknowledges; a source
|
||||
/// that knows the alarm is a genuinely new statement must send Retrigger.
|
||||
/// </summary>
|
||||
/// <param name="nodeId">The materialised condition node's id (the projection's state key).</param>
|
||||
/// <param name="e">The native alarm transition.</param>
|
||||
/// <param name="restatement">True when <paramref name="e"/> re-stated an already-active condition.</param>
|
||||
/// <returns>The full Part 9 condition snapshot to write to the node.</returns>
|
||||
public AlarmConditionSnapshot Project(string nodeId, AlarmEventArgs e, out bool restatement)
|
||||
{
|
||||
var prev = _prior.TryGetValue(nodeId, out var p) ? p : (Active: false, Acked: true);
|
||||
// #626: a source with a finer scale than the four buckets supplies the exact Part 9 severity.
|
||||
var sev = e.OpcUaSeverity is { } exact ? (ushort)Math.Clamp(exact, 1, 1000) : MapSeverity(e.Severity);
|
||||
restatement = e.Kind == AlarmTransitionKind.Raise && prev.Active;
|
||||
var (active, acked) = e.Kind switch
|
||||
{
|
||||
AlarmTransitionKind.Raise when prev.Active => (true, prev.Acked),
|
||||
AlarmTransitionKind.Raise or AlarmTransitionKind.Retrigger => (true, false),
|
||||
AlarmTransitionKind.Acknowledge => (prev.Active, true),
|
||||
AlarmTransitionKind.Clear => (false, prev.Acked),
|
||||
|
||||
Reference in New Issue