fix(alarms): #647 review — Raise on an active condition is a re-statement; FOCAS outage quality + health
MAJOR-1: a deploy that changes a driver's config respawns it, and the fresh instance's empty told record re-sent Raise for every still-active alarm, un-acking acknowledged conditions and writing a duplicate "Activated" alerts row. NativeAlarmProjector now treats Raise on an already-active condition as a re-statement (keeps Acked; ForwardNativeAlarm skips the alerts row); only Retrigger (or inactive->active) un-acks. Sources whose upstream ack state is authoritative send Retrigger for an unacked re-statement: OpcUaClient on first sight (no prior told), Galaxy for an unacked active snapshot entry. Runtime E2E drives a FRESH FOCAS driver after a redeploy and asserts the ack survives. MAJOR-2: a failed FOCAS alarm read annotates each subscribed condition BadNoCommunication once per outage (#626 quality-only path) with one Warning (MINOR-6), lifted to Good on recovery; failed alarm reads degrade driver health with LastSuccessfulRead frozen (successful ones advance it), so an alarm-only driver trips the #527 comms-loss watchdog. MINOR-3 CLAUDE.md #630 bullet; MINOR-4 split line; MINOR-5 a non-empty cnc_rdalmmsg2 payload that fits neither stride throws; MINOR-7 value-tag + parsed-address tables are built and swapped, never cleared in place under the retained poll engine. Docs corrected (FOCAS.md, AlarmTracking.md, CLAUDE.md). Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
This commit is contained in:
+18
-8
@@ -398,14 +398,24 @@ it, then author `ALARM:T<code>`. Number ranges are series-independent.
|
||||
**Delivery and failure.**
|
||||
|
||||
- **A failed read is not "no alarms".** `IFocasClient.ReadAlarmsAsync` throws on a down session, a non-OK
|
||||
return code or a wire fault; that device is skipped for the tick and its conditions keep their state. (It
|
||||
used to answer `[]`, which would have cleared every alarm on a comms blip and re-raised them un-acknowledged
|
||||
on recovery.) Driver-wide comms loss is the host's `BadNoCommunication` quality annotation (#477) — Active
|
||||
is kept.
|
||||
- **Diffed against what the server was TOLD**, recorded only while a handler is attached, and held for the
|
||||
driver's lifetime: a reconnect (same-set re-subscribe), a re-initialise and a shutdown/init cycle re-raise
|
||||
nothing, so an acknowledgement survives them. A changed subscribed set (an alarm-bearing deploy) prunes only
|
||||
the RawPaths that left (#641).
|
||||
return code, a wire fault, or a non-empty reply that fits neither the 76- nor the 80-byte record layout (an
|
||||
empty reply is "no alarms"). That device is skipped for the tick and its conditions keep their Active/Acked
|
||||
state. (It used to answer `[]`, which would have cleared every alarm on a comms blip and re-raised them
|
||||
un-acknowledged on recovery.)
|
||||
- **…but an unreachable source says so.** The first failed read of an outage annotates every subscribed condition
|
||||
on that device `BadNoCommunication` through the #626 quality-only path (no state change, no `/alerts` row) and
|
||||
logs ONE Warning naming `cnc_rdalmmsg2`; the next successful read lifts it to Good (before any transition it
|
||||
also finds, e.g. Good then Clear for an alarm that cleared during the outage). Failed alarm reads also reach
|
||||
driver health: `Degraded` with `LastSuccessfulRead` frozen (only a successful read advances it), so a driver
|
||||
whose only tags are `ALARM:` tags trips the comms-loss watchdog (#527) and the host's driver-wide #477
|
||||
annotation like any other.
|
||||
- **Diffed against what the server was TOLD**, recorded only while a handler is attached. The record lives on the
|
||||
driver instance: a reconnect (same-set re-subscribe) and an in-place re-initialise (Force Reconnect, #630) re-raise
|
||||
nothing. **A deploy that changes the driver's config respawns it** (the planner stops + recreates the driver, a new
|
||||
instance with an empty record), and its first poll sends `Raise` for every still-active alarm. The host treats a
|
||||
`Raise` on a condition it already shows Active as a **re-statement**: the acknowledgement is kept and no second
|
||||
"Activated" `/alerts` row is written (`NativeAlarmProjector`, #647 review). Only `Retrigger` — or inactive →
|
||||
active — un-acknowledges, which is why a genuinely new CNC alarm in a matched set is sent as `Retrigger`.
|
||||
- **Polling:** one `cnc_rdalmmsg2` per `AlarmProjection.PollInterval` (default 2 s) for each device that owns a
|
||||
**subscribed** alarm tag; devices without one are never polled for alarms.
|
||||
- **Opt-in is the tag.** `AlarmProjection.Enabled` is retained so old configs bind, and has no effect. Before
|
||||
|
||||