fix(twincat): string subscriptions, Windows-1252 STRING decode, and declared-type kind checks (ignitionoee 0.19.2-0.19.4)
Port of the ignitionoee TwinCAT string + type-reconciliation fixes onto the Beckhoff-library client: - STRING/WSTRING subscriptions never worked: AddDeviceNotificationExAsync was called with typeof(string) and no length, and the Beckhoff any-type marshaller throws ArgumentNullException for a string without one, so one string tag tore down its whole subscribe call. A string now registers the PLC's own byte width as raw bytes (0.19.2: STRING(n) of any n). - Strings are read as raw bytes and decoded by TwinCATStringCodec. The Beckhoff marshaller already cut a read at the first NUL (0.19.3 / TwinCAT-007 were not defects on the read path); the codec keeps that rule for both STRING and WSTRING and extends it to the new notification path. A STRING now decodes as Windows-1252 (TwinCAT-010) - or UTF-8 when the target reports UTF-8 strings - instead of the host culture's ANSI code page the Beckhoff marshaller falls back to (1250 on a Polish host, 1251 Cyrillic, ...). - TwinCATTypeGuard (TwinCAT-002/-008): a read refuses a numeric tag over a PLC string (and vice versa / STRING vs WSTRING / string over a container) with BadTypeMismatch instead of handing back a string object at Good; a notification - raw bytes decoded as the DECLARED type - additionally refuses width and float/integer mismatches (DINT over REAL reinterpreted the bits). - A refused notification is isolated: that tag publishes BadTypeMismatch with one WARN, keeps a dead intent for the probe-tick retry, and the rest of the subscription registers.
This commit is contained in:
@@ -41,6 +41,7 @@ internal sealed class AdsTwinCATClient : ITwinCATClient
|
||||
private readonly CancellationTokenSource _dispatchCts = new();
|
||||
private readonly Task _dispatchLoop;
|
||||
private int _disposed;
|
||||
private bool? _stringsAreUtf8;
|
||||
|
||||
/// <summary>
|
||||
/// Initializes a new instance of the <see cref="AdsTwinCATClient"/> class.
|
||||
@@ -125,6 +126,27 @@ internal sealed class AdsTwinCATClient : ITwinCATClient
|
||||
return (arrResult.Value, TwinCATStatusMapper.Good);
|
||||
}
|
||||
|
||||
// Scalar read: check the declared type against the PLC symbol first. The symbol is
|
||||
// resolved through the Beckhoff symbol cache (the same lookup ReadValueAsync makes
|
||||
// internally), so this costs no extra round trip after the first read.
|
||||
var (shape, symbolStatus) = await DescribeSymbolAsync(symbolPath, cancellationToken)
|
||||
.ConfigureAwait(false);
|
||||
if (symbolStatus != TwinCATStatusMapper.Good) return (null, symbolStatus);
|
||||
if (TwinCATTypeGuard.CheckRead(type, shape) is not null)
|
||||
return (null, TwinCATStatusMapper.BadTypeMismatch);
|
||||
|
||||
// A STRING / WSTRING is read as its raw bytes at the PLC's own declared width and
|
||||
// decoded here: it ends at the first NUL, and a STRING is Windows-1252 rather than the
|
||||
// host culture's ANSI code page the Beckhoff marshaller would fall back to.
|
||||
if (type is TwinCATDataType.String or TwinCATDataType.WString)
|
||||
{
|
||||
var raw = await _client.ReadValueAsync(symbolPath, typeof(byte[]), cancellationToken)
|
||||
.ConfigureAwait(false);
|
||||
if (raw.ErrorCode != AdsErrorCode.NoError)
|
||||
return (null, MapAndSignal((uint)raw.ErrorCode));
|
||||
return (DecodeString(type, raw.Value as byte[] ?? [], StringsAreUtf8()), TwinCATStatusMapper.Good);
|
||||
}
|
||||
|
||||
var clrType = MapToClrType(type);
|
||||
var result = await _client.ReadValueAsync(symbolPath, clrType, cancellationToken)
|
||||
.ConfigureAwait(false);
|
||||
@@ -140,6 +162,51 @@ internal sealed class AdsTwinCATClient : ITwinCATClient
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Resolves the PLC symbol behind <paramref name="symbolPath"/> into the facts
|
||||
/// <see cref="TwinCATTypeGuard"/> compares a declared type against. Uses the Beckhoff symbol
|
||||
/// cache (lookup on), so repeat calls are local.
|
||||
/// </summary>
|
||||
private async Task<(TwinCATPlcSymbolShape shape, uint status)> DescribeSymbolAsync(
|
||||
string symbolPath, CancellationToken cancellationToken)
|
||||
{
|
||||
var result = await _client.ReadSymbolAsync(symbolPath, cancellationToken).ConfigureAwait(false);
|
||||
if (result.ErrorCode != AdsErrorCode.NoError)
|
||||
return (default, MapAndSignal((uint)result.ErrorCode));
|
||||
if (result.Value is not { } symbol)
|
||||
return (default, TwinCATStatusMapper.BadNodeIdUnknown);
|
||||
|
||||
// Resolve aliases (T_MaxString → STRING(255)) so the guard sees the base type.
|
||||
var dataType = symbol.DataType?.Resolve();
|
||||
return (TwinCATPlcSymbolShape.Classify(dataType?.Name ?? symbol.TypeName, dataType?.Category, symbol.ByteSize),
|
||||
TwinCATStatusMapper.Good);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// True when the target reports UTF-8 STRING data (TwinCAT 3.1 4026+ "UTF8 Encoding for
|
||||
/// STRING"); otherwise a STRING is Windows-1252. Read once per client from the symbol upload
|
||||
/// info the Beckhoff client already fetches.
|
||||
/// </summary>
|
||||
private bool StringsAreUtf8()
|
||||
{
|
||||
if (_stringsAreUtf8 is bool known) return known;
|
||||
try
|
||||
{
|
||||
var utf8 = _client.DefaultValueEncoding.CodePage == System.Text.Encoding.UTF8.CodePage;
|
||||
_stringsAreUtf8 = utf8;
|
||||
return utf8;
|
||||
}
|
||||
catch
|
||||
{
|
||||
return false; // not determinable yet (e.g. not connected) — Windows-1252, retry next time
|
||||
}
|
||||
}
|
||||
|
||||
private static string DecodeString(TwinCATDataType type, byte[] bytes, bool utf8) =>
|
||||
type == TwinCATDataType.WString
|
||||
? TwinCATStringCodec.DecodeWString(bytes)
|
||||
: TwinCATStringCodec.DecodeString(bytes, utf8);
|
||||
|
||||
private static string StripBitSuffix(string symbolPath)
|
||||
{
|
||||
var lastDot = symbolPath.LastIndexOf('.');
|
||||
@@ -197,6 +264,33 @@ internal sealed class AdsTwinCATClient : ITwinCATClient
|
||||
CancellationToken cancellationToken)
|
||||
{
|
||||
var clrType = MapToClrType(type);
|
||||
int[]? anyTypeArgs = null;
|
||||
var stringsUtf8 = false;
|
||||
if (bitIndex is null || type != TwinCATDataType.Bool)
|
||||
{
|
||||
// A notification carries raw bytes decoded as the DECLARED type, so a declared type that
|
||||
// cannot decode the PLC symbol (width, float/integer or string kind differ) would publish
|
||||
// wrong values at Good. Refuse it here; the driver isolates the one tag to Bad.
|
||||
var (shape, symbolStatus) = await DescribeSymbolAsync(symbolPath, cancellationToken)
|
||||
.ConfigureAwait(false);
|
||||
if (symbolStatus != TwinCATStatusMapper.Good)
|
||||
throw new InvalidOperationException(
|
||||
$"Resolving {symbolPath} for a notification failed with status 0x{symbolStatus:X8}");
|
||||
if (TwinCATTypeGuard.CheckNotification(type, shape) is { } reason)
|
||||
throw new TwinCATTypeMismatchException(symbolPath, reason);
|
||||
|
||||
// A string has no fixed width: the "any" type string needs an explicit length (the
|
||||
// Beckhoff marshaller throws ArgumentNullException without one), and a STRING(n) is n+1
|
||||
// bytes with n chosen per declaration. Register the PLC's own byte width as raw bytes
|
||||
// and decode them in OnAdsNotificationEx with the same rules as a read.
|
||||
if (type is TwinCATDataType.String or TwinCATDataType.WString)
|
||||
{
|
||||
clrType = typeof(byte[]);
|
||||
anyTypeArgs = [shape.ByteSize];
|
||||
stringsUtf8 = StringsAreUtf8();
|
||||
}
|
||||
}
|
||||
|
||||
var cycleMs = (int)Math.Max(1, cycleTime.TotalMilliseconds);
|
||||
var settings = new NotificationSettings(AdsTransMode.OnChange, cycleMs, Math.Max(0, maxDelayMs));
|
||||
|
||||
@@ -204,13 +298,16 @@ internal sealed class AdsTwinCATClient : ITwinCATClient
|
||||
// with the handle as part of the event args so we use the handle as the correlation
|
||||
// key into _notifications.
|
||||
var result = await _client.AddDeviceNotificationExAsync(
|
||||
symbolPath, settings, userData: null, clrType, args: null, cancellationToken)
|
||||
symbolPath, settings, userData: null, clrType, anyTypeArgs, cancellationToken)
|
||||
.ConfigureAwait(false);
|
||||
if (result.ErrorCode != AdsErrorCode.NoError)
|
||||
throw new InvalidOperationException(
|
||||
$"AddDeviceNotificationExAsync failed with ADS error {result.ErrorCode} for {symbolPath}");
|
||||
|
||||
var reg = new NotificationRegistration(symbolPath, type, bitIndex, onChange, this, result.Handle);
|
||||
var reg = new NotificationRegistration(symbolPath, type, bitIndex, onChange, this, result.Handle)
|
||||
{
|
||||
StringsUtf8 = stringsUtf8,
|
||||
};
|
||||
_notifications[result.Handle] = reg;
|
||||
return reg;
|
||||
}
|
||||
@@ -227,6 +324,8 @@ internal sealed class AdsTwinCATClient : ITwinCATClient
|
||||
var value = args.Value;
|
||||
if (reg.BitIndex is int bit && reg.Type == TwinCATDataType.Bool && value is not bool)
|
||||
value = ExtractBit(value, bit);
|
||||
else if (value is byte[] raw && reg.Type is TwinCATDataType.String or TwinCATDataType.WString)
|
||||
value = DecodeString(reg.Type, raw, reg.StringsUtf8);
|
||||
_notificationQueue.Writer.TryWrite(new PendingNotification(reg, value));
|
||||
}
|
||||
|
||||
@@ -472,6 +571,11 @@ internal sealed class AdsTwinCATClient : ITwinCATClient
|
||||
/// </summary>
|
||||
public Action<string, object?> OnChange { get; } = onChange;
|
||||
|
||||
/// <summary>
|
||||
/// Gets a value indicating whether a STRING notification decodes as UTF-8 (else Windows-1252).
|
||||
/// </summary>
|
||||
public bool StringsUtf8 { get; init; }
|
||||
|
||||
/// <summary>
|
||||
/// Disposes the notification subscription.
|
||||
/// </summary>
|
||||
|
||||
@@ -94,6 +94,9 @@ public interface ITwinCATClient : IDisposable
|
||||
/// <param name="onChange">Invoked with <c>(symbolPath, boxedValue)</c> per notification.</param>
|
||||
/// <param name="cancellationToken">Cancels the initial registration; does not tear down an established notification.</param>
|
||||
/// <returns>A handle whose disposal tears the registered notification down.</returns>
|
||||
/// <exception cref="TwinCATTypeMismatchException">The declared <paramref name="type"/> cannot decode
|
||||
/// the PLC symbol (width, float/integer or string kind differ) — the caller isolates that one tag
|
||||
/// to Bad rather than registering a notification that would publish wrong bytes at Good.</exception>
|
||||
Task<ITwinCATNotificationHandle> AddNotificationAsync(
|
||||
string symbolPath,
|
||||
TwinCATDataType type,
|
||||
|
||||
@@ -276,9 +276,15 @@ public sealed class TwinCATDriver : IDriver, IReadable, IWritable, ITagDiscovery
|
||||
_health = new DriverHealth(DriverState.Healthy, now, null);
|
||||
else
|
||||
{
|
||||
_logger.LogWarning(
|
||||
"TwinCAT driver '{DriverInstanceId}' ADS read error 0x{Status:X8} for '{Reference}'",
|
||||
_driverInstanceId, status, reference);
|
||||
if (status == TwinCATStatusMapper.BadTypeMismatch)
|
||||
_logger.LogWarning(
|
||||
"TwinCAT driver '{DriverInstanceId}' refused '{Reference}': declared {DataType} " +
|
||||
"does not match the PLC symbol '{Symbol}' (string vs numeric)",
|
||||
_driverInstanceId, reference, def.DataType, symbolName);
|
||||
else
|
||||
_logger.LogWarning(
|
||||
"TwinCAT driver '{DriverInstanceId}' ADS read error 0x{Status:X8} for '{Reference}'",
|
||||
_driverInstanceId, status, reference);
|
||||
_health = new DriverHealth(DriverState.Degraded, _health.LastSuccessfulRead,
|
||||
$"ADS status {status:X8} reading {reference}");
|
||||
}
|
||||
@@ -535,7 +541,22 @@ public sealed class TwinCATDriver : IDriver, IReadable, IWritable, ITagDiscovery
|
||||
new DataChangeEventArgs(handle, reference, new DataValueSnapshot(
|
||||
null, TwinCATStatusMapper.BadCommunicationError, null, DateTime.UtcNow))));
|
||||
|
||||
await RegisterNotificationAsync(device, reg, cancellationToken).ConfigureAwait(false);
|
||||
try
|
||||
{
|
||||
await RegisterNotificationAsync(device, reg, cancellationToken).ConfigureAwait(false);
|
||||
}
|
||||
catch (TwinCATTypeMismatchException mismatch)
|
||||
{
|
||||
// The declared type cannot decode this PLC symbol (ignitionoee TwinCAT-002/-008):
|
||||
// isolate THIS tag to Bad — one WARN, one BadTypeMismatch snapshot — and keep the
|
||||
// rest of the subscription. Its intent stays on the device with no live handle,
|
||||
// so the probe-tick retry re-checks it after a PLC program change.
|
||||
_logger.LogWarning(
|
||||
"TwinCAT driver '{DriverInstanceId}' refused native notification for '{Reference}': {Reason}",
|
||||
_driverInstanceId, reference, mismatch.Message);
|
||||
OnDataChange?.Invoke(this, new DataChangeEventArgs(handle, reference, new DataValueSnapshot(
|
||||
null, TwinCATStatusMapper.BadTypeMismatch, null, DateTime.UtcNow)));
|
||||
}
|
||||
registrations.Add(reg);
|
||||
}
|
||||
}
|
||||
@@ -569,9 +590,20 @@ public sealed class TwinCATDriver : IDriver, IReadable, IWritable, ITagDiscovery
|
||||
try
|
||||
{
|
||||
var client = await EnsureConnectedUnderGateAsync(device, ct, timeoutOverride: null).ConfigureAwait(false);
|
||||
var newHandle = await client.AddNotificationAsync(
|
||||
reg.SymbolName, reg.DataType, reg.BitIndex, reg.Interval,
|
||||
_options.NotificationMaxDelayMs, reg.OnChange, ct).ConfigureAwait(false);
|
||||
ITwinCATNotificationHandle newHandle;
|
||||
try
|
||||
{
|
||||
newHandle = await client.AddNotificationAsync(
|
||||
reg.SymbolName, reg.DataType, reg.BitIndex, reg.Interval,
|
||||
_options.NotificationMaxDelayMs, reg.OnChange, ct).ConfigureAwait(false);
|
||||
}
|
||||
catch (TwinCATTypeMismatchException)
|
||||
{
|
||||
// Keep the intent with no live handle (a "dead" registration) so the probe-tick
|
||||
// retry re-checks it and UnsubscribeAsync still removes it; the caller isolates it.
|
||||
device.NativeRegistrations[reg.Id] = reg;
|
||||
throw;
|
||||
}
|
||||
reg.SwapHandle(newHandle); // initial set — previous handle is null
|
||||
device.NativeRegistrations[reg.Id] = reg;
|
||||
}
|
||||
|
||||
@@ -0,0 +1,69 @@
|
||||
using System.Text;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.TwinCAT;
|
||||
|
||||
/// <summary>
|
||||
/// Decodes an IEC <c>STRING(n)</c> / <c>WSTRING(n)</c> buffer read at the PLC's own declared width.
|
||||
/// The driver reads string symbols as raw bytes and decodes them here instead of letting the
|
||||
/// Beckhoff marshaller pick an encoding, because that marshaller falls back to the HOST's ANSI code
|
||||
/// page (<c>CultureInfo.CurrentCulture.TextInfo.ANSICodePage</c>) for a non-UTF-8 target — so a
|
||||
/// TwinCAT 2 string would decode differently on a Polish (1250) or Cyrillic (1251) server.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// Two rules, both ported from the ignitionoee TwinCAT driver and both found on a real PLC:
|
||||
/// <list type="bullet">
|
||||
/// <item>A value ENDS at its first NUL — <c>0x00</c> for a STRING, an aligned <c>0x00 0x00</c>
|
||||
/// code unit for a WSTRING. Whatever follows is stale content a longer earlier value left in the
|
||||
/// buffer (live on the Elma cleaner Z33856: work order <c>67504440</c> read back with a stale
|
||||
/// <c>"\0" + "1"</c> tail).</item>
|
||||
/// <item>A STRING is single-byte <b>Windows-1252</b> (umlauts, <c>°</c> in alarm texts), unless
|
||||
/// the target reports UTF-8 string data (TwinCAT 3.1 4026+ "UTF8 Encoding for STRING").
|
||||
/// ISO-8859-1 is the fallback on a runtime without code-page support — identical outside
|
||||
/// 0x80–0x9F.</item>
|
||||
/// </list>
|
||||
/// </remarks>
|
||||
internal static class TwinCATStringCodec
|
||||
{
|
||||
private static readonly Encoding Windows1252 = CreateWindows1252();
|
||||
|
||||
private static Encoding CreateWindows1252()
|
||||
{
|
||||
try
|
||||
{
|
||||
Encoding.RegisterProvider(CodePagesEncodingProvider.Instance);
|
||||
return Encoding.GetEncoding(1252);
|
||||
}
|
||||
catch (Exception)
|
||||
{
|
||||
return Encoding.Latin1;
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>Decodes an IEC <c>STRING(n)</c> buffer: ends at the first NUL, Windows-1252 unless <paramref name="utf8"/>.</summary>
|
||||
/// <param name="bytes">The raw symbol bytes (n+1 for a <c>STRING(n)</c>).</param>
|
||||
/// <param name="utf8">True when the target reports UTF-8 string data.</param>
|
||||
/// <returns>The decoded value.</returns>
|
||||
public static string DecodeString(ReadOnlySpan<byte> bytes, bool utf8)
|
||||
{
|
||||
var end = bytes.IndexOf((byte)0);
|
||||
if (end >= 0) bytes = bytes[..end];
|
||||
return (utf8 ? Encoding.UTF8 : Windows1252).GetString(bytes);
|
||||
}
|
||||
|
||||
/// <summary>Decodes an IEC <c>WSTRING(n)</c> buffer (UTF-16LE): ends at the first aligned <c>U+0000</c>.</summary>
|
||||
/// <param name="bytes">The raw symbol bytes (2(n+1) for a <c>WSTRING(n)</c>).</param>
|
||||
/// <returns>The decoded value.</returns>
|
||||
public static string DecodeWString(ReadOnlySpan<byte> bytes)
|
||||
{
|
||||
var end = bytes.Length & ~1; // whole UTF-16 code units only — a trailing odd byte is ignored
|
||||
for (var i = 0; i + 1 < end; i += 2)
|
||||
{
|
||||
if (bytes[i] == 0 && bytes[i + 1] == 0)
|
||||
{
|
||||
end = i;
|
||||
break;
|
||||
}
|
||||
}
|
||||
return Encoding.Unicode.GetString(bytes[..end]);
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,149 @@
|
||||
using System.Text.RegularExpressions;
|
||||
using TwinCAT.TypeSystem;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.TwinCAT;
|
||||
|
||||
/// <summary>What kind of value a PLC symbol holds, as far as the type guard is concerned.</summary>
|
||||
internal enum TwinCATPlcKind
|
||||
{
|
||||
/// <summary>A primitive / enum / alias-of-primitive — a single fixed-width value.</summary>
|
||||
Scalar,
|
||||
|
||||
/// <summary>An IEC <c>STRING(n)</c> (any n, incl. an alias such as <c>T_MaxString</c>).</summary>
|
||||
String,
|
||||
|
||||
/// <summary>An IEC <c>WSTRING(n)</c>.</summary>
|
||||
WString,
|
||||
|
||||
/// <summary>A struct / FB / array / pointer / reference / <c>VAR_IN_OUT</c> — no scalar value.</summary>
|
||||
NonScalar,
|
||||
}
|
||||
|
||||
/// <summary>The facts about a PLC symbol the type guard compares a declared type against.</summary>
|
||||
/// <param name="Kind">The symbol's kind.</param>
|
||||
/// <param name="ByteSize">The symbol's byte size as the PLC reports it.</param>
|
||||
/// <param name="IsFloat">True for a REAL / LREAL scalar.</param>
|
||||
/// <param name="TypeName">The (alias-resolved) PLC type name, for log messages.</param>
|
||||
internal readonly record struct TwinCATPlcSymbolShape(TwinCATPlcKind Kind, int ByteSize, bool IsFloat, string TypeName)
|
||||
{
|
||||
private static readonly Regex StringTypeName =
|
||||
new(@"^(W?)STRING(\s*\(\s*\d+\s*\))?$", RegexOptions.IgnoreCase | RegexOptions.CultureInvariant);
|
||||
|
||||
/// <summary>
|
||||
/// Classifies a PLC symbol from its (alias-resolved) type name, its Beckhoff
|
||||
/// <see cref="DataTypeCategory"/> when the type system resolved one, and its byte size.
|
||||
/// </summary>
|
||||
/// <param name="typeName">The PLC type name (<c>STRING(80)</c>, <c>INT16</c>, <c>ST_LOGDATA</c>, …).</param>
|
||||
/// <param name="category">The resolved type category, or null when the type system has none.</param>
|
||||
/// <param name="byteSize">The symbol's byte size.</param>
|
||||
/// <returns>The classified shape.</returns>
|
||||
public static TwinCATPlcSymbolShape Classify(string? typeName, DataTypeCategory? category, int byteSize)
|
||||
{
|
||||
var name = (typeName ?? string.Empty).Trim();
|
||||
var match = StringTypeName.Match(name);
|
||||
if (match.Success || category == DataTypeCategory.String)
|
||||
{
|
||||
var wide = match.Success
|
||||
? match.Groups[1].Length > 0
|
||||
: name.StartsWith("WSTRING", StringComparison.OrdinalIgnoreCase);
|
||||
return new(wide ? TwinCATPlcKind.WString : TwinCATPlcKind.String, byteSize, false, name);
|
||||
}
|
||||
|
||||
if (category is DataTypeCategory.Array or DataTypeCategory.Struct or DataTypeCategory.FunctionBlock
|
||||
or DataTypeCategory.Program or DataTypeCategory.Pointer or DataTypeCategory.Reference
|
||||
or DataTypeCategory.Union or DataTypeCategory.Interface
|
||||
|| name.StartsWith("ARRAY", StringComparison.OrdinalIgnoreCase)
|
||||
|| name.StartsWith("POINTER TO", StringComparison.OrdinalIgnoreCase)
|
||||
|| name.StartsWith("REFERENCE TO", StringComparison.OrdinalIgnoreCase)
|
||||
|| name.Contains("VAR_IN_OUT", StringComparison.OrdinalIgnoreCase))
|
||||
return new(TwinCATPlcKind.NonScalar, byteSize, false, name);
|
||||
|
||||
var mapped = AdsTwinCATClient.MapSymbolTypeName(name);
|
||||
return new(TwinCATPlcKind.Scalar, byteSize, mapped is TwinCATDataType.Real or TwinCATDataType.LReal, name);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Decides whether a tag's DECLARED <see cref="TwinCATDataType"/> may decode the PLC symbol it names —
|
||||
/// the port of the ignitionoee TwinCAT driver's extra-type reconciliation (TwinCAT-002, -008). A
|
||||
/// refused pair leaves the node Bad (<see cref="TwinCATStatusMapper.BadTypeMismatch"/>) instead of
|
||||
/// publishing the PLC's bytes decoded as the wrong type at Good quality. A <c>null</c> result means
|
||||
/// compatible; otherwise it is a one-line reason for the log.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// The two paths need different rules because they decode differently:
|
||||
/// <list type="bullet">
|
||||
/// <item><b>Read</b> (<see cref="CheckRead"/>) goes through the Beckhoff symbol cache, which
|
||||
/// decodes by the PLC's OWN type and converts the value to the declared CLR type — a numeric
|
||||
/// pair is value-converted, never reinterpreted. Only string-ness can go wrong there: a
|
||||
/// numeric tag over a PLC string got a <c>string</c> object back at Good.</item>
|
||||
/// <item><b>Notification</b> (<see cref="CheckNotification"/>) registers raw bytes decoded as the
|
||||
/// DECLARED type, so a width mismatch truncates/over-reads and a same-width float/integer clash
|
||||
/// reinterprets the bit pattern — both at Good.</item>
|
||||
/// </list>
|
||||
/// String-ness is a KIND (TwinCAT-008): a STRING/WSTRING tag matches only a PLC string of the SAME
|
||||
/// kind, at any declared length (0.19.2). A same-width, same-kind numeric divergence
|
||||
/// (<c>DINT</c> vs <c>UDINT</c>, <c>TIME</c> vs a 4-byte integer) is tolerated so a valid config is
|
||||
/// never refused.
|
||||
/// </remarks>
|
||||
internal static class TwinCATTypeGuard
|
||||
{
|
||||
/// <summary>Checks a declared type against a PLC symbol for a symbol-aware READ.</summary>
|
||||
/// <param name="declared">The tag's declared type.</param>
|
||||
/// <param name="plc">The PLC symbol's shape.</param>
|
||||
/// <returns><c>null</c> when compatible; otherwise the reason.</returns>
|
||||
public static string? CheckRead(TwinCATDataType declared, TwinCATPlcSymbolShape plc)
|
||||
{
|
||||
var declaredKind = StringKindOf(declared);
|
||||
if (declaredKind is not null)
|
||||
{
|
||||
return plc.Kind == declaredKind
|
||||
? null
|
||||
: $"declared {declared} but the PLC symbol is {plc.TypeName} ({plc.ByteSize} B) — a string tag " +
|
||||
$"matches only a PLC {declaredKind.Value.ToString().ToUpperInvariant()} of any length";
|
||||
}
|
||||
return plc.Kind is TwinCATPlcKind.String or TwinCATPlcKind.WString
|
||||
? $"declared {declared} but the PLC symbol is the string {plc.TypeName} — declare it String/WString"
|
||||
: null;
|
||||
}
|
||||
|
||||
/// <summary>Checks a declared type against a PLC symbol for a raw-bytes NOTIFICATION.</summary>
|
||||
/// <param name="declared">The tag's declared type.</param>
|
||||
/// <param name="plc">The PLC symbol's shape.</param>
|
||||
/// <returns><c>null</c> when compatible; otherwise the reason.</returns>
|
||||
public static string? CheckNotification(TwinCATDataType declared, TwinCATPlcSymbolShape plc)
|
||||
{
|
||||
var reason = CheckRead(declared, plc);
|
||||
if (reason is not null || StringKindOf(declared) is not null) return reason;
|
||||
|
||||
if (plc.Kind == TwinCATPlcKind.NonScalar)
|
||||
return $"declared scalar {declared} but the PLC symbol is {plc.TypeName} ({plc.ByteSize} B) — not a scalar";
|
||||
|
||||
var size = DeclaredByteSize(declared);
|
||||
if (size != plc.ByteSize)
|
||||
return $"declared {declared} ({size} B) but the PLC symbol {plc.TypeName} is {plc.ByteSize} B";
|
||||
|
||||
var declaredFloat = declared is TwinCATDataType.Real or TwinCATDataType.LReal;
|
||||
return declaredFloat == plc.IsFloat
|
||||
? null
|
||||
: $"declared {declared} but the PLC symbol is {plc.TypeName} — float/integer kinds differ";
|
||||
}
|
||||
|
||||
/// <summary>The byte width the declared type decodes from a notification buffer.</summary>
|
||||
/// <param name="type">The declared type.</param>
|
||||
/// <returns>The width in bytes.</returns>
|
||||
internal static int DeclaredByteSize(TwinCATDataType type) => type switch
|
||||
{
|
||||
TwinCATDataType.Bool or TwinCATDataType.SInt or TwinCATDataType.USInt => 1,
|
||||
TwinCATDataType.Int or TwinCATDataType.UInt => 2,
|
||||
TwinCATDataType.LInt or TwinCATDataType.ULInt or TwinCATDataType.LReal => 8,
|
||||
_ => 4, // DInt / UDInt / Real / Time / Date / DateTime / TimeOfDay
|
||||
};
|
||||
|
||||
private static TwinCATPlcKind? StringKindOf(TwinCATDataType type) => type switch
|
||||
{
|
||||
TwinCATDataType.String => TwinCATPlcKind.String,
|
||||
TwinCATDataType.WString => TwinCATPlcKind.WString,
|
||||
_ => null,
|
||||
};
|
||||
}
|
||||
@@ -0,0 +1,22 @@
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.TwinCAT;
|
||||
|
||||
/// <summary>
|
||||
/// Thrown by <see cref="ITwinCATClient.AddNotificationAsync"/> when a tag's declared
|
||||
/// <see cref="TwinCATDataType"/> cannot decode the PLC symbol it names (see
|
||||
/// <see cref="TwinCATTypeGuard"/>). The driver isolates the one tag to
|
||||
/// <see cref="TwinCATStatusMapper.BadTypeMismatch"/> and keeps the rest of the subscription.
|
||||
/// </summary>
|
||||
internal sealed class TwinCATTypeMismatchException : Exception
|
||||
{
|
||||
/// <summary>Initializes a new instance of the <see cref="TwinCATTypeMismatchException"/> class.</summary>
|
||||
/// <param name="symbolPath">The ADS symbol the tag names.</param>
|
||||
/// <param name="reason">The guard's one-line reason.</param>
|
||||
public TwinCATTypeMismatchException(string symbolPath, string reason)
|
||||
: base($"TwinCAT symbol '{symbolPath}': {reason}")
|
||||
{
|
||||
SymbolPath = symbolPath;
|
||||
}
|
||||
|
||||
/// <summary>Gets the ADS symbol the refused tag names.</summary>
|
||||
public string SymbolPath { get; }
|
||||
}
|
||||