docs: fill missing XML docs and strip tracking IDs from src comments
Clears CommentChecker findings in src/ (3,280 -> 209, the remainder being false positives like PLC-5/IEEE-754/M0.0) by adding missing summaries/params/returns, normalising inheritdoc usage, and removing Gitea/review tracking IDs while keeping the rationale they annotated. Comment-only: comment-stripped sources are identical to the parent commit.
This commit is contained in:
@@ -31,7 +31,7 @@ public sealed class FocasDriverOptions
|
||||
public FocasHandleRecycleOptions HandleRecycle { get; init; } = new();
|
||||
/// <summary>Gets the fixed tree options.</summary>
|
||||
public FocasFixedTreeOptions FixedTree { get; init; } = new();
|
||||
/// <summary>Gets the PMC range-coalescing options (Gitea #266).</summary>
|
||||
/// <summary>Gets the PMC range-coalescing options.</summary>
|
||||
public FocasPmcCoalesceOptions PmcCoalesce { get; init; } = new();
|
||||
|
||||
/// <summary>
|
||||
@@ -44,7 +44,7 @@ public sealed class FocasDriverOptions
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Merges adjacent / near PMC reads in one poll batch into fewer <c>pmc_rdpmcrng</c> calls (Gitea #266).
|
||||
/// Merges adjacent / near PMC reads in one poll batch into fewer <c>pmc_rdpmcrng</c> calls.
|
||||
/// On by default: a batch with a single PMC tag per area is unaffected, and a coalesced read the CNC
|
||||
/// rejects falls back to per-tag reads, so enabling it cannot make a readable tag unreadable.
|
||||
/// </summary>
|
||||
@@ -128,19 +128,19 @@ public sealed class FocasHandleRecycleOptions
|
||||
|
||||
/// <summary>
|
||||
/// Controls the CNC active-alarm polling projection that surfaces FOCAS alarms via
|
||||
/// <c>IAlarmSource</c> as Part 9 conditions at <c>ALARM:</c> raw tags (Gitea #647).
|
||||
/// <c>IAlarmSource</c> as Part 9 conditions at <c>ALARM:</c> raw tags.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <b>Authoring an <c>ALARM:</c> tag IS the opt-in.</b> The projection polls exactly the devices that own a
|
||||
/// subscribed alarm tag, so a driver with none issues no <c>cnc_rdalmmsg2</c> traffic whatever
|
||||
/// <see cref="Enabled"/> says. Before #647, <see cref="Enabled"/> gated the poll and
|
||||
/// <see cref="Enabled"/> says. Previously <see cref="Enabled"/> gated the poll and
|
||||
/// <c>SubscribeAlarmsAsync</c> THREW while it was false — so an operator who authored an alarm tag and left
|
||||
/// the default got a feed that stayed gated with a Warning on every reconnect. It is retained so existing
|
||||
/// configs still bind, and no longer has any effect.
|
||||
/// </remarks>
|
||||
public sealed class FocasAlarmProjectionOptions
|
||||
{
|
||||
/// <summary>Retained for config compatibility; has no effect since Gitea #647 (see the class remarks).</summary>
|
||||
/// <summary>Retained for config compatibility; has no effect (see the class remarks).</summary>
|
||||
public bool Enabled { get; init; } = false;
|
||||
|
||||
/// <summary>Poll cadence. One <c>cnc_rdalmmsg2</c> call per device per tick.</summary>
|
||||
@@ -204,7 +204,7 @@ public sealed record FocasDeviceOptions(
|
||||
/// clients can optimise write coalescing for idempotent tags. Defaults to <c>false</c>.
|
||||
/// </param>
|
||||
/// <param name="Alarm">
|
||||
/// The tag's cross-driver <c>alarm</c> object, when it carries one (Gitea #647) — which makes the host
|
||||
/// The tag's cross-driver <c>alarm</c> object, when it carries one — which makes the host
|
||||
/// materialise it as a Part 9 condition at its RawPath. Only an <c>ALARM:</c> address can drive one.
|
||||
/// </param>
|
||||
public sealed record FocasTagDefinition(
|
||||
@@ -217,7 +217,7 @@ public sealed record FocasTagDefinition(
|
||||
FocasTagAlarm? Alarm = null);
|
||||
|
||||
/// <summary>
|
||||
/// What the FOCAS driver reads from a tag's cross-driver <c>alarm</c> object (Gitea #647). The host owns the
|
||||
/// What the FOCAS driver reads from a tag's cross-driver <c>alarm</c> object. The host owns the
|
||||
/// rest of it (<c>alarmType</c>, <c>historizeToAveva</c>) through <c>TagConfigIntent</c>.
|
||||
/// </summary>
|
||||
/// <param name="Severity">
|
||||
|
||||
Reference in New Issue
Block a user