docs: fill missing XML docs and strip tracking IDs from src comments
Clears CommentChecker findings in src/ (3,280 -> 209, the remainder being false positives like PLC-5/IEEE-754/M0.0) by adding missing summaries/params/returns, normalising inheritdoc usage, and removing Gitea/review tracking IDs while keeping the rationale they annotated. Comment-only: comment-stripped sources are identical to the parent commit.
This commit is contained in:
@@ -87,8 +87,8 @@ public sealed class PollGroupEngine : IAsyncDisposable
|
||||
/// internal contract-violation throw) so the owning driver can route the failure to its
|
||||
/// health surface. Defensive: an <c>onError</c> handler that
|
||||
/// itself throws is silently absorbed so a buggy forwarder cannot crash the poll loop.</param>
|
||||
/// <param name="backoffCap">Optional cap enabling capped-exponential failure backoff
|
||||
/// (05/STAB-8). When supplied, sustained reader failures stretch the retry cadence
|
||||
/// <param name="backoffCap">Optional cap enabling capped-exponential failure backoff.
|
||||
/// When supplied, sustained reader failures stretch the retry cadence
|
||||
/// (interval, 2×, 4×, … saturating at this cap) instead of hammering a dead device every
|
||||
/// tick; a successful poll resets to the base interval. <c>null</c> (default) keeps the
|
||||
/// byte-identical fixed-interval cadence for consumers that have not opted in.
|
||||
@@ -260,7 +260,7 @@ public sealed class PollGroupEngine : IAsyncDisposable
|
||||
consecutiveFailures = 0;
|
||||
}
|
||||
// Only a teardown OCE (the loop's OWN token) exits the loop. A reader that throws OCE with
|
||||
// the loop token un-cancelled — a driver-internal timeout CTS (the STAB-14/STAB-15 class) —
|
||||
// the loop token un-cancelled — a driver-internal timeout CTS (the class of failure) —
|
||||
// must NOT tear the loop down: it falls through to the generic handler, is reported, and the
|
||||
// loop retries with backoff. This is the guard that makes the S7 fork migration safe.
|
||||
catch (OperationCanceledException) when (ct.IsCancellationRequested) { return; }
|
||||
@@ -319,7 +319,7 @@ public sealed class PollGroupEngine : IAsyncDisposable
|
||||
consecutiveFailures = 0;
|
||||
}
|
||||
// Only teardown (the loop token) exits; a reader OCE with ct un-cancelled backs off
|
||||
// like any other failure instead of killing the loop (STAB-14 engine guard).
|
||||
// like any other failure instead of killing the loop.
|
||||
catch (OperationCanceledException) when (ct.IsCancellationRequested) { return; }
|
||||
catch (Exception ex) when (!IsFatal(ex))
|
||||
{
|
||||
|
||||
Reference in New Issue
Block a user