feat(historian): honor per-alarm HistorizeToAveva opt-out at the durable write

This commit is contained in:
Joseph Doherty
2026-06-11 12:48:13 -04:00
parent fa839d1dbf
commit 8012509584
6 changed files with 78 additions and 9 deletions
@@ -16,6 +16,7 @@ namespace ZB.MOM.WW.OtOpcUa.Commons.Messages.Alerts;
/// <param name="TimestampUtc">When the transition occurred.</param>
/// <param name="AlarmTypeName">OPC UA Part 9 condition subtype name — one of <c>LimitAlarm</c> / <c>DiscreteAlarm</c> / <c>OffNormalAlarm</c> / <c>AlarmCondition</c> (the base type, used as the default). The historian feed maps this onto the durable alarm-type column.</param>
/// <param name="Comment">Operator-supplied comment on ack / confirm / comment transitions; <c>null</c> for engine-driven transitions (Activated / Cleared / Shelved / …) that carry no comment.</param>
/// <param name="HistorizeToAveva">When <c>false</c>, the durable historian sink suppresses this transition (the live <c>alerts</c> fan-out is unaffected). Defaults to <c>true</c>. On a rolling restart an old-format message deserializes this as <c>false</c> (CLR default); that is safe because the writing node is always the same-version publisher — see HistorianAdapterActor.</param>
public sealed record AlarmTransitionEvent(
string AlarmId,
string EquipmentPath,
@@ -26,4 +27,5 @@ public sealed record AlarmTransitionEvent(
string User,
DateTime TimestampUtc,
string AlarmTypeName = "AlarmCondition",
string? Comment = null);
string? Comment = null,
bool HistorizeToAveva = true);