test(historian): paged-vs-unpaged raw-cap fuzz, MaxReturnDataValues advertisement, cap floor of 3
- NodeManagerHistoryReadRawCapFuzzTests: 10k seeds (env OTOPCUA_PAGING_FUZZ_ITERATIONS)
through a real SDK node manager against wire-faithful fakes of SqlServer / QuestDB /
Gateway that enforce the backend half of the cap; random series with ties, random
windows (empty, on/past a tie, between samples, forward/reverse/end-only, bounds),
N in {0,1,2,small,huge}, cap in {off,3..1000}, tie budget {3,8,65536}. Pages must
concatenate to the cap-off one-shot answer (checked against the series), terminate
within values + 2 (+ one empty step per oversized boundary cluster), never exceed
the cap, never ask the backend for 0 / over-cap; refusals only past the budget.
- HistoryPaging.AdvertiseMaxReturnDataValues writes HistoryServerCapabilities/
MaxReturnDataValues (i=11273), read back through the SDK master node manager.
- MinMaxRawValuesPerRead raised to 3: at 2 a resumed page has no room (value + its
boundary tie + lookahead) and every value cost an empty page + CP (seed 15).
- RawPageLimit rows pin the default-cap arithmetic (9 999 first page, 9 998 resumed).
Fuzz findings recorded as follow-ups: a bounded read whose data fits one page
returns cap + 1 (end bound fitted against N, not the cap; node manager, F2);
the Gateway walk-back's cost on a sparse series under a tiny tie budget is
pre-existing (seed 320: 82 reads uncapped, 93 capped).
Refs #736
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
This commit is contained in:
@@ -1,3 +1,5 @@
|
||||
using Opc.Ua;
|
||||
using Opc.Ua.Server;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.OpcUaServer;
|
||||
@@ -110,16 +112,51 @@ internal enum HistoryCursorKind
|
||||
/// <c>NumValuesPerNode</c> samples with a null continuation point — so paging is synthesised here,
|
||||
/// time-based:
|
||||
/// <list type="bullet">
|
||||
/// <item>A page that returns EXACTLY the requested cap (<c>NumValuesPerNode > 0</c>) MAY have
|
||||
/// more behind it ⇒ emit a continuation point.</item>
|
||||
/// <item>A short page (fewer than the cap) is the last page ⇒ no continuation point.</item>
|
||||
/// <item><c>NumValuesPerNode == 0</c> means "all values, no limit" (OPC UA Part 11) ⇒ never page;
|
||||
/// return everything in one shot.</item>
|
||||
/// <item>A page whose read returned the lookahead row past it MAY have more behind it ⇒ emit a continuation
|
||||
/// point (<see cref="IsFullPage"/> judges a read against what was asked for).</item>
|
||||
/// <item>A short read (no lookahead row) is the last page ⇒ no continuation point.</item>
|
||||
/// <item><c>NumValuesPerNode == 0</c> means "all values" (OPC UA Part 11) — but not "in one shot": the page is
|
||||
/// sized to the backend's <see cref="IHistorianDataSource.MaxRawValuesPerRead"/> by <see cref="RawPageLimit"/>
|
||||
/// (the server raw cap <c>ServerHistorian:MaxRawValuesPerRead</c>, default 10 000, and/or a strict gateway's
|
||||
/// learned ceiling; review R08:1.1, #736), and a full page carries a continuation point like any other. Only
|
||||
/// with no limit at all (<c>0</c>, the opt-out) is everything returned in one shot.</item>
|
||||
/// </list>
|
||||
/// All methods are static + pure so they unit-test without a server, a session, or the SDK.
|
||||
/// All paging methods are static + pure so they unit-test without a server, a session, or the SDK;
|
||||
/// <see cref="AdvertiseMaxReturnDataValues"/> is the one SDK-facing member.
|
||||
/// </summary>
|
||||
internal static class HistoryPaging
|
||||
{
|
||||
/// <summary>
|
||||
/// Advertise the server raw cap as <c>HistoryServerCapabilities/MaxReturnDataValues</c> (i=11273; Part 11 §5.4.2:
|
||||
/// "the maximum number of values that can be returned by the Server for each Node", 0 = no limit). The cap is
|
||||
/// the most values one HistoryRead-Raw page returns (<c>ServerHistorian:MaxRawValuesPerRead</c>), so a client can
|
||||
/// size its <c>NumValuesPerNode</c> and expect a continuation point past it. Idempotent; a re-sync with a
|
||||
/// different cap overwrites. Never throws: a missing diagnostics manager or node leaves the SDK default (0) and
|
||||
/// returns <c>false</c> — HistoryRead itself still enforces the cap.
|
||||
/// </summary>
|
||||
/// <param name="server">The running server.</param>
|
||||
/// <param name="maxRawValuesPerRead">The cap (<= 0 advertises 0 = no limit).</param>
|
||||
/// <returns><c>true</c> when the property was written.</returns>
|
||||
public static bool AdvertiseMaxReturnDataValues(IServerInternal? server, int maxRawValuesPerRead)
|
||||
{
|
||||
if (server?.DiagnosticsNodeManager is not DiagnosticsNodeManager diagnostics) return false;
|
||||
try
|
||||
{
|
||||
lock (diagnostics.Lock)
|
||||
{
|
||||
var capabilities = diagnostics.GetDefaultHistoryCapabilities();
|
||||
if (capabilities?.MaxReturnDataValues is not { } property) return false;
|
||||
property.Value = (uint)Math.Max(0, maxRawValuesPerRead);
|
||||
property.ClearChangeMasks(diagnostics.SystemContext, false);
|
||||
return true;
|
||||
}
|
||||
}
|
||||
catch (ServiceResultException)
|
||||
{
|
||||
return false;
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Decide whether a just-returned page is "full" and therefore MAY be followed by more data —
|
||||
/// the signal to emit a continuation point. A page is full when the client asked for a finite
|
||||
|
||||
Reference in New Issue