Parent: #209. Follow-up to #210 (Modbus). Registers the remaining three non-Galaxy driver factories so a Config DB `DriverType` in {`AbCip`, `S7`, `AbLegacy`} actually boots a live driver instead of being silently skipped by DriverInstanceBootstrapper. Each factory follows the same shape as ModbusDriverFactoryExtensions + the existing Galaxy + FOCAS patterns: - Static `Register(DriverFactoryRegistry)` entry point. - Internal `CreateInstance(driverInstanceId, driverConfigJson)` — deserialises a DTO, strict-parses enum fields (fail-fast with an explicit "expected one of" list), composes the driver's options object, returns a new driver. - DriverType keys: `"AbCip"`, `"S7"`, `"AbLegacy"` (case-insensitive at the registry layer). DTO surfaces cover every option the respective driver's Options class exposes — devices, tags, probe, timeouts, per-driver quirks (AbCip `EnableControllerBrowse` / `EnableAlarmProjection`, S7 Rack/Slot/ CpuType, AbLegacy PlcFamily). Seed SQL (mirrors `seed-modbus-smoke.sql` shape): - `seed-abcip-smoke.sql` — `abcip-smoke` cluster + ControlLogix device + `TestDINT:DInt` tag, pointing at the ab_server compose fixture (`ab://127.0.0.1:44818/1,0`). - `seed-s7-smoke.sql` — `s7-smoke` cluster + S71500 CPU + `DB1.DBW0:Int16` tag at the python-snap7 fixture (`127.0.0.1:1102`, non-priv port). - `seed-ablegacy-smoke.sql` — `ablegacy-smoke` cluster + SLC 500 + `N7:5` tag. Hardware-gated per #222; placeholder gateway to be replaced with real SLC/MicroLogix/PLC-5/RSEmulate before running. Build plumbing: - Each driver project now ProjectReferences `Core` (was `Core.Abstractions`-only). `DriverFactoryRegistry` lives in `Core.Hosting` so the factory extensions can't compile without it. Matches the FOCAS + Galaxy.Proxy reference shape. - `Server.csproj` adds the three new driver ProjectReferences so Program.cs resolves the symbols at compile-time + ships the assemblies at runtime. Full-solution build: 0 errors, 334 pre-existing xUnit1051 warnings only. Live boot verification of all four (Modbus + these three) happens in the exit-gate PR — factories + seeds are pre-conditions and are being shipped first so the exit-gate PR can scope to "does the server publish the expected NodeIds + does the e2e script pass." Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
117
scripts/smoke/seed-ablegacy-smoke.sql
Normal file
117
scripts/smoke/seed-ablegacy-smoke.sql
Normal file
@@ -0,0 +1,117 @@
|
||||
-- AB Legacy e2e smoke seed — closes #213 (umbrella #209).
|
||||
--
|
||||
-- Hardware-gated. The ab_server PCCC dispatcher is upstream-broken (task #222
|
||||
-- tracks the lab rig + alternative fixtures), so verifying this seed end-to-end
|
||||
-- requires real SLC 500 / MicroLogix / PLC-5 hardware or an RSEmulate 500
|
||||
-- golden-box. The factory + seed ship here so the wiring is in place the
|
||||
-- moment real hardware becomes available — no server code changes needed.
|
||||
--
|
||||
-- Usage (once hardware is reachable):
|
||||
-- sqlcmd -S "localhost,14330" -d OtOpcUaConfig -U sa -P "OtOpcUaDev_2026!" \
|
||||
-- -i scripts/smoke/seed-ablegacy-smoke.sql
|
||||
-- (Update the `HostAddress` below to point at the real gateway first.)
|
||||
|
||||
SET NOCOUNT ON;
|
||||
SET XACT_ABORT ON;
|
||||
SET QUOTED_IDENTIFIER ON;
|
||||
SET ANSI_NULLS ON;
|
||||
SET ANSI_PADDING ON;
|
||||
SET ANSI_WARNINGS ON;
|
||||
SET ARITHABORT ON;
|
||||
SET CONCAT_NULL_YIELDS_NULL ON;
|
||||
|
||||
DECLARE @ClusterId nvarchar(64) = 'ablegacy-smoke';
|
||||
DECLARE @NodeId nvarchar(64) = 'ablegacy-smoke-node';
|
||||
DECLARE @DrvId nvarchar(64) = 'ablegacy-smoke-drv';
|
||||
DECLARE @NsId nvarchar(64) = 'ablegacy-smoke-ns';
|
||||
DECLARE @AreaId nvarchar(64) = 'ablegacy-smoke-area';
|
||||
DECLARE @LineId nvarchar(64) = 'ablegacy-smoke-line';
|
||||
DECLARE @EqId nvarchar(64) = 'ablegacy-smoke-eq';
|
||||
DECLARE @EqUuid uniqueidentifier = '5A1D2030-5A1D-4203-A5A1-D20305A1D203';
|
||||
DECLARE @TagId nvarchar(64) = 'ablegacy-smoke-tag-n7_5';
|
||||
|
||||
BEGIN TRAN;
|
||||
|
||||
DELETE FROM dbo.Tag WHERE TagId IN (@TagId);
|
||||
DELETE FROM dbo.Equipment WHERE EquipmentId = @EqId;
|
||||
DELETE FROM dbo.UnsLine WHERE UnsLineId = @LineId;
|
||||
DELETE FROM dbo.UnsArea WHERE UnsAreaId = @AreaId;
|
||||
DELETE FROM dbo.DriverInstance WHERE DriverInstanceId = @DrvId;
|
||||
DELETE FROM dbo.Namespace WHERE NamespaceId = @NsId;
|
||||
DELETE FROM dbo.ConfigGeneration WHERE ClusterId = @ClusterId;
|
||||
DELETE FROM dbo.ClusterNodeCredential WHERE NodeId = @NodeId;
|
||||
DELETE FROM dbo.ClusterNodeGenerationState WHERE NodeId = @NodeId;
|
||||
DELETE FROM dbo.ClusterNode WHERE NodeId = @NodeId;
|
||||
DELETE FROM dbo.ServerCluster WHERE ClusterId = @ClusterId;
|
||||
|
||||
INSERT dbo.ServerCluster(ClusterId, Name, Enterprise, Site, NodeCount, RedundancyMode, Enabled, CreatedBy)
|
||||
VALUES (@ClusterId, 'AB Legacy Smoke', 'zb', 'lab', 1, 'None', 1, 'ablegacy-smoke');
|
||||
|
||||
INSERT dbo.ClusterNode(NodeId, ClusterId, RedundancyRole, Host, OpcUaPort, DashboardPort,
|
||||
ApplicationUri, ServiceLevelBase, Enabled, CreatedBy)
|
||||
VALUES (@NodeId, @ClusterId, 'Primary', 'localhost', 4840, 5000,
|
||||
'urn:OtOpcUa:ablegacy-smoke-node', 200, 1, 'ablegacy-smoke');
|
||||
|
||||
DECLARE @Gen bigint;
|
||||
INSERT dbo.ConfigGeneration(ClusterId, Status, CreatedBy)
|
||||
VALUES (@ClusterId, 'Draft', 'ablegacy-smoke');
|
||||
SET @Gen = SCOPE_IDENTITY();
|
||||
|
||||
INSERT dbo.Namespace(GenerationId, NamespaceId, ClusterId, Kind, NamespaceUri, Enabled)
|
||||
VALUES (@Gen, @NsId, @ClusterId, 'Equipment', 'urn:ablegacy-smoke:eq', 1);
|
||||
|
||||
INSERT dbo.UnsArea(GenerationId, UnsAreaId, ClusterId, Name)
|
||||
VALUES (@Gen, @AreaId, @ClusterId, 'lab-floor');
|
||||
|
||||
INSERT dbo.UnsLine(GenerationId, UnsLineId, UnsAreaId, Name)
|
||||
VALUES (@Gen, @LineId, @AreaId, 'ablegacy-line');
|
||||
|
||||
INSERT dbo.Equipment(GenerationId, EquipmentId, EquipmentUuid, DriverInstanceId, UnsLineId,
|
||||
Name, MachineCode, Enabled)
|
||||
VALUES (@Gen, @EqId, @EqUuid, @DrvId, @LineId, 'slc-sim', 'ablegacy-001', 1);
|
||||
|
||||
-- AB Legacy DriverInstance — SLC 500 target. Replace the placeholder gateway
|
||||
-- `192.168.1.10` with the real PLC / RSEmulate host before running.
|
||||
INSERT dbo.DriverInstance(GenerationId, DriverInstanceId, ClusterId, NamespaceId,
|
||||
Name, DriverType, DriverConfig, Enabled)
|
||||
VALUES (@Gen, @DrvId, @ClusterId, @NsId, 'ablegacy-smoke', 'AbLegacy', N'{
|
||||
"TimeoutMs": 2000,
|
||||
"Devices": [
|
||||
{
|
||||
"HostAddress": "ab://192.168.1.10/1,0",
|
||||
"PlcFamily": "Slc500",
|
||||
"DeviceName": "slc-500"
|
||||
}
|
||||
],
|
||||
"Probe": { "Enabled": true, "IntervalMs": 5000, "TimeoutMs": 2000, "ProbeAddress": "S:0" },
|
||||
"Tags": [
|
||||
{
|
||||
"Name": "N7_5",
|
||||
"DeviceHostAddress": "ab://192.168.1.10/1,0",
|
||||
"Address": "N7:5",
|
||||
"DataType": "Int",
|
||||
"Writable": true,
|
||||
"WriteIdempotent": true
|
||||
}
|
||||
]
|
||||
}', 1);
|
||||
|
||||
INSERT dbo.Tag(GenerationId, TagId, DriverInstanceId, EquipmentId, Name, DataType,
|
||||
AccessLevel, TagConfig, WriteIdempotent)
|
||||
VALUES (@Gen, @TagId, @DrvId, @EqId, 'N7_5', 'Int16', 'ReadWrite',
|
||||
N'{"FullName":"N7_5","Address":"N7:5","DataType":"Int"}', 1);
|
||||
|
||||
EXEC dbo.sp_PublishGeneration @ClusterId = @ClusterId, @DraftGenerationId = @Gen,
|
||||
@Notes = N'AB Legacy smoke — task #213';
|
||||
|
||||
COMMIT;
|
||||
|
||||
PRINT '';
|
||||
PRINT 'AB Legacy smoke seed complete.';
|
||||
PRINT ' Cluster: ' + @ClusterId;
|
||||
PRINT ' Node: ' + @NodeId;
|
||||
PRINT ' Generation: ' + CONVERT(nvarchar(20), @Gen);
|
||||
PRINT '';
|
||||
PRINT 'NOTE: hardware-gated. ab_server PCCC is upstream-broken (#222). Point the';
|
||||
PRINT ' DriverConfig HostAddress at real SLC / MicroLogix / PLC-5 / RSEmulate';
|
||||
PRINT ' and run the e2e script with AB_LEGACY_TRUST_WIRE=1.';
|
||||