v3 Batch 3 WP1: UNS Equipment Tags tab → reference list + raw-tag picker

Replace the Batch-1-stubbed authored-tag flow with a UnsTagReference list on the
equipment page's Tags tab (v3 reference-only equipment): columns are effective name,
computed raw path, inherited datatype/access (read-only), display-name override
(editable), and remove. The retired equipment-authored-tag editor (TagModal.razor)
is deleted; the VirtualTag and ScriptedAlarm flows are untouched.

- "+ Add reference" opens a new AddReferenceModal that reuses RawTree in a new opt-in
  PickerMode (Tag-leaf checkboxes + Device/TagGroup "select all tags below"), scoped
  structurally to the equipment's cluster via LoadReferencePickerRootAsync (a single
  cluster root — cross-cluster tags are unreachable, not merely hidden). Default /raw
  usage is byte-unchanged (PickerMode defaults false).
- UnsTreeService (+ IUnsTreeService) gain the reference mutations:
  LoadReferencesForEquipmentAsync (computes each RawPath via the shared RawPathResolver),
  AddReferencesAsync (cluster-checked, all-or-nothing), RemoveReferenceAsync,
  SetReferenceOverrideAsync, plus the picker helpers LoadReferencePickerRootAsync /
  LoadDescendantTagIdsAsync.
- Consume IEffectiveNameGuard (constructor-injected, no-op fallback when unregistered):
  AddReferences, SetReferenceOverride, and the VirtualTag + ScriptedAlarm create/update
  mutations now call CheckAsync before persisting and surface a collision as the failure.
  WP2 supplies the implementation + DI registration.
- Drop the retired equipment↔driver binding: remove DriverInstanceId from EquipmentInput,
  the ImportEquipmentModal CSV column, the EquipmentPage Details driver select, and the
  dead decision-#122 driver-cluster guard.

Tests: new UnsTreeServiceReferenceTests (add/remove/override, cross-cluster + duplicate
rejection, guard-consumed rejection via a fake guard, RawPath projection, picker helpers);
Equipment/Import test suites rewritten to drop the retired driver-guard cases. AdminUI
suite green (639 passed, 3 skipped); full solution builds 0 errors.

Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
This commit is contained in:
Joseph Doherty
2026-07-16 06:15:51 -04:00
parent 6dc5af7aa2
commit 77bc010ba9
12 changed files with 1161 additions and 1060 deletions
@@ -11,7 +11,6 @@ namespace ZB.MOM.WW.OtOpcUa.AdminUI.Uns;
/// <param name="Name">UNS level-5 segment; matches <c>^[a-z0-9-]{1,32}$</c>.</param>
/// <param name="MachineCode">Operator colloquial id; unique fleet-wide.</param>
/// <param name="UnsLineId">Logical FK to the owning <see cref="Configuration.Entities.UnsLine"/>.</param>
/// <param name="DriverInstanceId">Optional driver binding; whitespace/empty means driver-less.</param>
/// <param name="ZTag">Optional ERP equipment id.</param>
/// <param name="SAPID">Optional SAP PM equipment id.</param>
/// <param name="Manufacturer">Optional OPC 40010 manufacturer name.</param>
@@ -28,7 +27,6 @@ public sealed record EquipmentInput(
string Name,
string MachineCode,
string UnsLineId,
string? DriverInstanceId,
string? ZTag,
string? SAPID,
string? Manufacturer,