fix(historian): read-only historian bindings + ProvisionTags policy; provision OPC UA type names (#899, #898)
v2-ci / unit-tests (push) Has been cancelled
v2-ci / unit-tests (push) Has been cancelled
#899 — EnsureTags is an upsert, so binding a node to an existing AVEVA tag via historianTagname re-typed/re-described it on every add and host start. - TagConfig `historianReadOnly: true` (TagConfigIntent -> RawTagPlan.HistorianReadOnly): HistoryRead from an existing historian tag that OtOpcUa never provisions and never records into (AddressSpaceApplier.IsOwnedHistorizedValue gates both the EnsureTags hook and the recorder feed). Node-inert: surgical, not mirrored on UNS refs, in the RawTagPlan equality/hash. A non-bool value is the deploy error HistorianReadOnlyInvalid. AdminUI: CSV column HistorianReadOnly (strict), TagHistorizeConfig reads via the runtime parse. - ServerHistorian:ProvisionTags = CreateOrUpdate (default, unchanged) | CreateOnly (Gateway only: TagExistsAsync first, existing tags left alone, failed lookup not sent) | Off. Unknown value / CreateOnly on a SQL backend fail host start. - Default for an explicit historianTagname stays OWNED: overrides pin owned history across renames, a read-only default would silently stop provisioning + recording. #898 — the hook parsed Tag.DataType (an OPC UA name) as DriverDataType, so historized Float/Double/Byte/SByte tags were never provisioned. New shared HistorianDataTypeNames.TryResolve: Float->Float32, Double->Float64, Byte/SByte->Int16 (lossless, provisioned as Int2); unmapped names logged at Information. Gateway now skips Int64/UInt64 (HistorianGateway cannot create Int8/UInt8: lossless-cast-or-reject). UPGRADE: the first host start after this provisions (upserts) every existing historized Float/Double/Byte/SByte tag. Mark foreign-tag bindings historianReadOnly, or set ServerHistorian:ProvisionTags=CreateOnly/Off, before upgrading (docs/Historian.md). Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
This commit is contained in:
+32
@@ -113,6 +113,38 @@ public sealed class AddHistorianProvisioningTests
|
||||
resolved.ShouldNotBeSameAs(NullHistorianProvisioning.Instance);
|
||||
}
|
||||
|
||||
/// <summary>lmxopcua#899: ServerHistorian:ProvisionTags=Off keeps the no-op even with the section enabled; the
|
||||
/// other policies register the backend's provisioner (control).</summary>
|
||||
[Theory]
|
||||
[InlineData("Off", false)]
|
||||
[InlineData("off", false)]
|
||||
[InlineData("CreateOnly", true)]
|
||||
[InlineData("CreateOrUpdate", true)]
|
||||
public void ProvisionTags_Off_keeps_null_provisioning(string policy, bool registered)
|
||||
{
|
||||
var factoryInvoked = false;
|
||||
var services = new ServiceCollection();
|
||||
services.AddOtOpcUaRuntime();
|
||||
var config = ConfigFrom(new Dictionary<string, string?>
|
||||
{
|
||||
["ServerHistorian:Enabled"] = "true",
|
||||
["ServerHistorian:Endpoint"] = "https://historian.example.com:5222",
|
||||
["ServerHistorian:ApiKey"] = "histgw_x_y",
|
||||
["ServerHistorian:ProvisionTags"] = policy,
|
||||
});
|
||||
|
||||
services.AddHistorianProvisioning(config, (_, _) =>
|
||||
{
|
||||
factoryInvoked = true;
|
||||
return new CapturingProvisioner();
|
||||
});
|
||||
|
||||
using var provider = services.BuildServiceProvider();
|
||||
var resolved = provider.GetRequiredService<IHistorianProvisioning>();
|
||||
(resolved is NullHistorianProvisioning).ShouldBe(!registered);
|
||||
factoryInvoked.ShouldBe(registered);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Section_enabled_passes_bound_options_to_factory()
|
||||
{
|
||||
|
||||
Reference in New Issue
Block a user