fix(historian): read-only historian bindings + ProvisionTags policy; provision OPC UA type names (#899, #898)
v2-ci / unit-tests (push) Has been cancelled
v2-ci / unit-tests (push) Has been cancelled
#899 — EnsureTags is an upsert, so binding a node to an existing AVEVA tag via historianTagname re-typed/re-described it on every add and host start. - TagConfig `historianReadOnly: true` (TagConfigIntent -> RawTagPlan.HistorianReadOnly): HistoryRead from an existing historian tag that OtOpcUa never provisions and never records into (AddressSpaceApplier.IsOwnedHistorizedValue gates both the EnsureTags hook and the recorder feed). Node-inert: surgical, not mirrored on UNS refs, in the RawTagPlan equality/hash. A non-bool value is the deploy error HistorianReadOnlyInvalid. AdminUI: CSV column HistorianReadOnly (strict), TagHistorizeConfig reads via the runtime parse. - ServerHistorian:ProvisionTags = CreateOrUpdate (default, unchanged) | CreateOnly (Gateway only: TagExistsAsync first, existing tags left alone, failed lookup not sent) | Off. Unknown value / CreateOnly on a SQL backend fail host start. - Default for an explicit historianTagname stays OWNED: overrides pin owned history across renames, a read-only default would silently stop provisioning + recording. #898 — the hook parsed Tag.DataType (an OPC UA name) as DriverDataType, so historized Float/Double/Byte/SByte tags were never provisioned. New shared HistorianDataTypeNames.TryResolve: Float->Float32, Double->Float64, Byte/SByte->Int16 (lossless, provisioned as Int2); unmapped names logged at Information. Gateway now skips Int64/UInt64 (HistorianGateway cannot create Int8/UInt8: lossless-cast-or-reject). UPGRADE: the first host start after this provisions (upserts) every existing historized Float/Double/Byte/SByte tag. Mark foreign-tag bindings historianReadOnly, or set ServerHistorian:ProvisionTags=CreateOnly/Off, before upgrading (docs/Historian.md). Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
This commit is contained in:
@@ -0,0 +1,58 @@
|
||||
namespace ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
|
||||
/// <summary>
|
||||
/// Resolves a raw tag's authored <c>DataType</c> string to the <see cref="DriverDataType"/> the historian
|
||||
/// provisioning contract (<see cref="HistorianTagProvisionRequest"/>) carries (lmxopcua#898).
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <para>
|
||||
/// <c>Tag.DataType</c> holds <b>OPC UA built-in type names</b> — what the AdminUI writes (<c>RawTagModal</c>,
|
||||
/// manual entry, CSV import, <c>RawBrowseCommitMapper</c>) and what <c>OtOpcUaNodeManager.ResolveBuiltInDataType</c>
|
||||
/// understands: <c>Float</c>, <c>Double</c>, <c>Byte</c>, <c>SByte</c>, … The provisioning hook used to
|
||||
/// <c>Enum.TryParse<DriverDataType></c> that string, which knows <c>Float32</c>/<c>Float64</c> but not
|
||||
/// <c>Float</c>/<c>Double</c>, and has no <c>Byte</c>/<c>SByte</c> member, so historized Float, Double, Byte and
|
||||
/// SByte tags were silently never provisioned.
|
||||
/// </para>
|
||||
/// <para>
|
||||
/// Mapping (case-insensitive, trimmed):
|
||||
/// <list type="bullet">
|
||||
/// <item><c>Float</c> ⇒ <see cref="DriverDataType.Float32"/>, <c>Double</c> ⇒ <see cref="DriverDataType.Float64"/>.</item>
|
||||
/// <item><c>Byte</c> (0..255) and <c>SByte</c> (−128..127) ⇒ <see cref="DriverDataType.Int16"/>: a lossless
|
||||
/// widening (HistorianGateway's lossless-cast-or-reject rule). Int16 provisions as the historian's
|
||||
/// <c>Int2</c>, the type Boolean already uses; the historian's one-byte <c>Int1</c> creation is
|
||||
/// server-degenerate (#441) and its <c>UInt2</c> write path is the one OtOpcUa still widens away from.</item>
|
||||
/// <item>The other OPC UA names that share a <see cref="DriverDataType"/> member name (<c>Boolean</c>,
|
||||
/// <c>Int16</c>…<c>UInt64</c>, <c>String</c>, <c>DateTime</c>) map to that member.</item>
|
||||
/// <item>A <see cref="DriverDataType"/> member name (<c>Float32</c>, <c>Float64</c>, <c>Reference</c>) is still
|
||||
/// accepted, as before.</item>
|
||||
/// <item>Anything else (<c>Guid</c>, <c>ByteString</c>, a number, blank) is unresolved: the caller skips the tag.</item>
|
||||
/// </list>
|
||||
/// Whether a resolved type is then historizable is the backend's decision (the Gateway skips
|
||||
/// String/DateTime/Reference and the 64-bit integers; the SQL backends take every type).
|
||||
/// </para>
|
||||
/// </remarks>
|
||||
public static class HistorianDataTypeNames
|
||||
{
|
||||
/// <summary>Resolves an authored tag data type name to the provisioning <see cref="DriverDataType"/>.</summary>
|
||||
/// <param name="dataType">The tag's <c>DataType</c> string (an OPC UA built-in name, or a <see cref="DriverDataType"/> name).</param>
|
||||
/// <param name="driverDataType">The resolved type when the method returns <see langword="true"/>.</param>
|
||||
/// <returns><see langword="true"/> when the name resolves; <see langword="false"/> for an unknown, numeric or blank name.</returns>
|
||||
public static bool TryResolve(string? dataType, out DriverDataType driverDataType)
|
||||
{
|
||||
driverDataType = default;
|
||||
var name = dataType?.Trim();
|
||||
if (string.IsNullOrEmpty(name)) return false;
|
||||
|
||||
switch (name.ToUpperInvariant())
|
||||
{
|
||||
case "FLOAT": driverDataType = DriverDataType.Float32; return true;
|
||||
case "DOUBLE": driverDataType = DriverDataType.Float64; return true;
|
||||
case "BYTE":
|
||||
case "SBYTE": driverDataType = DriverDataType.Int16; return true;
|
||||
}
|
||||
|
||||
// Enum.TryParse also accepts a bare number ("3") or a comma list — neither is a type name.
|
||||
if (!char.IsLetter(name[0]) || name.Contains(',')) return false;
|
||||
return Enum.TryParse(name, ignoreCase: true, out driverDataType) && Enum.IsDefined(driverDataType);
|
||||
}
|
||||
}
|
||||
@@ -47,8 +47,10 @@ public sealed record HistorianTagProvisionRequest(
|
||||
/// </summary>
|
||||
/// <param name="Requested">Total tags submitted.</param>
|
||||
/// <param name="Ensured">Tags the historian acknowledged as created or already present.</param>
|
||||
/// <param name="Skipped">Tags whose data type is not historizable on the backend (never sent).</param>
|
||||
/// <param name="Failed">Tags that were sent but the backend did not acknowledge (incl. a swallowed transport error).</param>
|
||||
/// <param name="Skipped">Tags never sent: a data type the backend cannot historize, or (Gateway
|
||||
/// <c>ServerHistorian:ProvisionTags=CreateOnly</c>, lmxopcua#899) a tag that already exists and is left unchanged.</param>
|
||||
/// <param name="Failed">Tags that were sent but the backend did not acknowledge (incl. a swallowed transport error), or —
|
||||
/// under <c>CreateOnly</c> — whose existence lookup failed, so they were not sent.</param>
|
||||
public sealed record HistorianProvisionResult(
|
||||
int Requested,
|
||||
int Ensured,
|
||||
|
||||