fix(historian): read-only historian bindings + ProvisionTags policy; provision OPC UA type names (#899, #898)
v2-ci / unit-tests (push) Has been cancelled
v2-ci / unit-tests (push) Has been cancelled
#899 — EnsureTags is an upsert, so binding a node to an existing AVEVA tag via historianTagname re-typed/re-described it on every add and host start. - TagConfig `historianReadOnly: true` (TagConfigIntent -> RawTagPlan.HistorianReadOnly): HistoryRead from an existing historian tag that OtOpcUa never provisions and never records into (AddressSpaceApplier.IsOwnedHistorizedValue gates both the EnsureTags hook and the recorder feed). Node-inert: surgical, not mirrored on UNS refs, in the RawTagPlan equality/hash. A non-bool value is the deploy error HistorianReadOnlyInvalid. AdminUI: CSV column HistorianReadOnly (strict), TagHistorizeConfig reads via the runtime parse. - ServerHistorian:ProvisionTags = CreateOrUpdate (default, unchanged) | CreateOnly (Gateway only: TagExistsAsync first, existing tags left alone, failed lookup not sent) | Off. Unknown value / CreateOnly on a SQL backend fail host start. - Default for an explicit historianTagname stays OWNED: overrides pin owned history across renames, a read-only default would silently stop provisioning + recording. #898 — the hook parsed Tag.DataType (an OPC UA name) as DriverDataType, so historized Float/Double/Byte/SByte tags were never provisioned. New shared HistorianDataTypeNames.TryResolve: Float->Float32, Double->Float64, Byte/SByte->Int16 (lossless, provisioned as Int2); unmapped names logged at Information. Gateway now skips Int64/UInt64 (HistorianGateway cannot create Int8/UInt8: lossless-cast-or-reject). UPGRADE: the first host start after this provisions (upserts) every existing historized Float/Double/Byte/SByte tag. Mark foreign-tag bindings historianReadOnly, or set ServerHistorian:ProvisionTags=CreateOnly/Off, before upgrading (docs/Historian.md). Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
This commit is contained in:
@@ -37,6 +37,7 @@ public static class DraftValidator
|
||||
// and ValidateGalaxyTagFullName (blob-as-identity gone) are replaced by:
|
||||
ValidateRawNameCharset(draft, errors);
|
||||
ValidateHistorizedTagnameLength(draft, errors);
|
||||
ValidateHistorianReadOnly(draft, errors);
|
||||
ValidateUnsEffectiveLeafUniqueness(draft, errors);
|
||||
ValidateEquipReferenceResolution(draft, errors);
|
||||
ValidateCalculationTags(draft, errors);
|
||||
@@ -720,6 +721,21 @@ public static class DraftValidator
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>lmxopcua#899: <c>historianReadOnly</c> must be a JSON boolean. The runtime parse
|
||||
/// (<see cref="TagConfigIntent.Parse"/>) honours only a bool <c>true</c>, so a string <c>"true"</c> would deploy as an
|
||||
/// OWNED tag — provisioned (<c>EnsureTags</c>, an upsert) and recorded into — exactly what the author asked not to
|
||||
/// happen to a historian tag OtOpcUa does not own. A deploy error, never a silent "owned".</summary>
|
||||
private static void ValidateHistorianReadOnly(DraftSnapshot draft, List<ValidationError> errors)
|
||||
{
|
||||
foreach (var t in draft.Tags)
|
||||
{
|
||||
if (!TagConfigIntent.HasMalformedHistorianReadOnly(t.TagConfig)) continue;
|
||||
errors.Add(new("HistorianReadOnlyInvalid",
|
||||
$"tag '{t.TagId}' TagConfig '{TagConfigIntent.HistorianReadOnlyKey}' must be a JSON boolean (true or false)",
|
||||
t.TagId));
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>v3: within an equipment, the EFFECTIVE leaf name must be unique across its UnsTagReferences
|
||||
/// (DisplayNameOverride else the backing raw tag's Name), its VirtualTags (Name), and its ScriptedAlarms
|
||||
/// (Name) — the three share the equipment's UNS NodeId space (<c>{EquipmentId}/{EffectiveName}</c>).
|
||||
|
||||
Reference in New Issue