The 2026-04-30 alarm plan banners claimed worker-side native alarm
subscription was blocked on a COM-bitness finding. That's stale: the
mxaccessgw .NET client now has true MxAccess alarm-event support, and a
live StreamAlarms check (+ new Skip-gated GatewayGalaxyAlarmFeedLiveTests
through the lmxopcua consumer) confirms native alarms — operator comment,
category, severity, timestamps — flow end-to-end. Reconcile both plan docs
to reality and add docs/plans/alarms-d1-smoke-artifact.md as the D.1
alarm-source deliverable. Historian-write live smoke + full server->A&C
round-trip remain (Windows parity rig only).
This commit is contained in:
Joseph Doherty
2026-05-31 09:59:01 -04:00
parent 61193629b6
commit 695fa6408b
5 changed files with 245 additions and 26 deletions
+33 -16
View File
@@ -9,24 +9,41 @@
> the new RPCs; the sub-attribute fallback path keeps Galaxy alarms
> functional today.
>
> ⚠️ **Worker-side native alarm subscription blocked on a dev-rig
> finding (2026-04-30):** the MXAccess COM Toolkit at
> **UPDATE 2026-05-29 — native alarm feed VERIFIED working; the
> 2026-04-30 "blocked" finding below is superseded.** A live
> `StreamAlarms` check against the gateway at `10.100.0.48:5120`
> returned the active-alarm snapshot (20 alarms) with full native
> metadata — `severity`, `category`, `currentState`,
> `lastTransitionTimestamp`, **and `operatorComment`** (the field the
> note below called "the only v1 regression"). The lmxopcua consumer
> (`GatewayGalaxyAlarmFeed` → `GalaxyAlarmTransition` →
> `AlarmEventArgs` → `IAlarmSource`) ingests it with full fidelity and
> the OPC UA severity-bucket mapping applied — proven by the passing
> Skip-gated live test `GatewayGalaxyAlarmFeedLiveTests`. `AlarmEventArgs`
> already carries operator-comment / original-raise-time / category, so
> **E.7 is done too**. See `docs/plans/alarms-d1-smoke-artifact.md` for
> the captured evidence. The gateway delivers this via **true MxAccess
> alarm-event support** in the mxaccessgw .NET client (a real
> alarm-event subscription — **not** the sub-attribute fallback), so A.2
> is implemented as originally specified. Still open: the scripted-alarm
> → AVEVA Historian write-back live smoke (C.1's `Live_*` leg) and a full
> running-server → OPC UA A&C round-trip — both need the Windows parity rig.
>
> ⚠️ **[SUPERSEDED — kept for history] Worker-side native alarm
> subscription blocked on a dev-rig finding (2026-04-30):** the MXAccess
> COM Toolkit at
> `C:\Program Files (x86)\ArchestrA\Framework\Bin\ArchestrA.MXAccess.dll`
> exposes no alarm-event family — only `OnDataChange`,
> `OnWriteComplete`, `OperationComplete`, `OnBufferedDataChange`.
> exposed no alarm-event family — only `OnDataChange`,
> `OnWriteComplete`, `OperationComplete`, `OnBufferedDataChange` — and
> AVEVA's `aaAlarmManagedClient` / `ArchestrAAlarmsAndEvents.SDK`
> assemblies are x64-only and incompatible with the worker's x86
> bitness. **Operator decision needed before
> `MX_EVENT_FAMILY_ON_ALARM_TRANSITION` carries any events:** either
> accept the value-driven sub-attribute path as the production
> architecture (operator-comment fidelity is the only v1 regression)
> or add an x64 alarm-helper sub-process alongside the worker. See
> `src/MxGateway.Worker/MxAccess/MxAccessAlarmEventSink.cs` in the
> mxaccessgw repo for the architectural notes. Live
> `aahClientManaged` alarm-event write call site
> (`SdkAlarmHistorianWriteBackend` placeholder from PR C.1) and the
> D.1 smoke artifact ship once those decisions resolve. The
> remainder of this document is preserved as the design record.
> assemblies are x64-only vs. the worker's x86 bitness. The operator
> decision (accept the value-driven sub-attribute path, or add an x64
> alarm-helper sub-process) has since been resolved on the gateway side
> — `MX_EVENT_FAMILY_ON_ALARM_TRANSITION` now carries events (verified
> above). The C.1 `SdkAlarmHistorianWriteBackend` is **no longer a
> placeholder** — it writes through the real
> `HistorianAccess.AddStreamedValue` path (only its live-rig write
> smoke remains).
Coordinated epic across two repos: