fix(driver-focas-cli): resolve Low code-review findings (Driver.FOCAS.Cli-001,002,003,004; -005 deferred)
- Driver.FOCAS.Cli-001: WriteCommand.ParseValue now wraps numeric FormatException / OverflowException as CliFx CommandException with the offending value. - Driver.FOCAS.Cli-002: SubscribeCommand's OnDataChange handler and the banner both take a writeLock so notification-callback and main-thread writes can't interleave; handler exceptions are warn-and-swallow. - Driver.FOCAS.Cli-003: FocasCommandBase.ValidateOptions rejects --cnc-port outside 1..65535, non-positive --timeout-ms, and non-positive --interval-ms; ExecuteAsync calls it first. - Driver.FOCAS.Cli-004: 'await using var driver' is the sole driver disposal path; dropped the redundant explicit await ShutdownAsync. - Driver.FOCAS.Cli-005 (Deferred): the fix lives in Driver.Cli.Common.SnapshotFormatter — explicitly naming the status-code shortlist there benefits every driver CLI. Left as a Driver.Cli.Common follow-up. - Registered the new tests/Drivers/Cli/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli.Tests project in ZB.MOM.WW.OtOpcUa.slnx. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -24,6 +24,8 @@ public sealed class ProbeCommand : FocasCommandBase
|
||||
public override async ValueTask ExecuteAsync(IConsole console)
|
||||
{
|
||||
ConfigureLogging();
|
||||
// Driver.FOCAS.Cli-003: validate numeric option ranges before any driver work.
|
||||
ValidateOptions();
|
||||
var ct = console.RegisterCancellationHandler();
|
||||
|
||||
var probeTag = new FocasTagDefinition(
|
||||
@@ -34,24 +36,20 @@ public sealed class ProbeCommand : FocasCommandBase
|
||||
Writable: false);
|
||||
var options = BuildOptions([probeTag]);
|
||||
|
||||
// Driver.FOCAS.Cli-004: `await using` is the sole disposal mechanism — FocasDriver.DisposeAsync
|
||||
// already invokes ShutdownAsync, so a redundant explicit ShutdownAsync(CancellationToken.None)
|
||||
// in a finally block ran shutdown twice. The await-using on the next line is enough.
|
||||
await using var driver = new FocasDriver(options, DriverInstanceId);
|
||||
try
|
||||
{
|
||||
await driver.InitializeAsync("{}", ct);
|
||||
var snapshot = await driver.ReadAsync(["__probe"], ct);
|
||||
var health = driver.GetHealth();
|
||||
await driver.InitializeAsync("{}", ct);
|
||||
var snapshot = await driver.ReadAsync(["__probe"], ct);
|
||||
var health = driver.GetHealth();
|
||||
|
||||
await console.Output.WriteLineAsync($"CNC: {CncHost}:{CncPort}");
|
||||
await console.Output.WriteLineAsync($"Series: {Series}");
|
||||
await console.Output.WriteLineAsync($"Health: {health.State}");
|
||||
if (health.LastError is { } err)
|
||||
await console.Output.WriteLineAsync($"Last error: {err}");
|
||||
await console.Output.WriteLineAsync();
|
||||
await console.Output.WriteLineAsync(SnapshotFormatter.Format(Address, snapshot[0]));
|
||||
}
|
||||
finally
|
||||
{
|
||||
await driver.ShutdownAsync(CancellationToken.None);
|
||||
}
|
||||
await console.Output.WriteLineAsync($"CNC: {CncHost}:{CncPort}");
|
||||
await console.Output.WriteLineAsync($"Series: {Series}");
|
||||
await console.Output.WriteLineAsync($"Health: {health.State}");
|
||||
if (health.LastError is { } err)
|
||||
await console.Output.WriteLineAsync($"Last error: {err}");
|
||||
await console.Output.WriteLineAsync();
|
||||
await console.Output.WriteLineAsync(SnapshotFormatter.Format(Address, snapshot[0]));
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue