fix(driver-s7-cli): resolve Low code-review findings (Driver.S7.Cli-004,005,006,007)

- Driver.S7.Cli-004: 'await using var driver' is the sole driver
  disposal path; dropped the redundant explicit await ShutdownAsync from
  each command's finally.
- Driver.S7.Cli-005: deleted the stale empty
  tests/ZB.MOM.WW.OtOpcUa.Driver.S7.Cli.Tests/ directory (the real test
  project lives under tests/Drivers/Cli/).
- Driver.S7.Cli-006: S7CommandBaseBuildOptionsTests cover the probe
  toggle, timeout mapping, host/port/CPU/rack/slot wiring, and tag list
  passthrough.
- Driver.S7.Cli-007: re-added the SubscribeCommand handler comment
  explaining the CliFx IConsole.Output usage and that the poll-thread
  raises events.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
Joseph Doherty
2026-05-23 08:34:48 -04:00
parent f46e126208
commit 67ef6c4ebc
8 changed files with 217 additions and 34 deletions

View File

@@ -0,0 +1,61 @@
using Shouldly;
using Xunit;
namespace ZB.MOM.WW.OtOpcUa.Driver.S7.Cli.Tests;
/// <summary>
/// Driver.S7.Cli-004: every S7 CLI command must own one disposal mechanism for the
/// <c>S7Driver</c>, not two. The chosen mechanism is <c>await using var driver = ...</c>
/// — <c>S7Driver.DisposeAsync</c> already calls <c>ShutdownAsync</c>, so an additional
/// explicit <c>driver.ShutdownAsync(...)</c> in a <c>finally</c> block runs shutdown
/// twice (three times on subscribe). These tests guard against that regression by
/// scanning the command source files.
/// </summary>
[Trait("Category", "Unit")]
public sealed class CommandDisposalConventionsTests
{
private static readonly string CommandsDir = LocateCommandsDir();
[Theory]
[InlineData("ProbeCommand.cs")]
[InlineData("ReadCommand.cs")]
[InlineData("WriteCommand.cs")]
[InlineData("SubscribeCommand.cs")]
public void Command_does_not_call_ShutdownAsync_explicitly(string commandFile)
{
var path = Path.Combine(CommandsDir, commandFile);
File.Exists(path).ShouldBeTrue($"Expected {path} to exist.");
var source = File.ReadAllText(path);
// The await-using statement is the single disposal mechanism. An explicit
// driver.ShutdownAsync(...) call (typically inside a finally block) re-invokes
// a shutdown path that DisposeAsync already runs and is the smell -004 flags.
source.ShouldNotContain("driver.ShutdownAsync(");
}
[Theory]
[InlineData("ProbeCommand.cs")]
[InlineData("ReadCommand.cs")]
[InlineData("WriteCommand.cs")]
[InlineData("SubscribeCommand.cs")]
public void Command_uses_await_using_for_S7Driver(string commandFile)
{
var path = Path.Combine(CommandsDir, commandFile);
var source = File.ReadAllText(path);
source.ShouldContain("await using var driver = new S7Driver(");
}
private static string LocateCommandsDir()
{
// Walk up from the test assembly bin/ folder to the repo root, then into the
// source project's Commands/ directory. The test-host puts CWD somewhere under
// bin/Debug/net10.0 so we resolve relative to AppContext.BaseDirectory.
var dir = new DirectoryInfo(AppContext.BaseDirectory);
while (dir is not null && !File.Exists(Path.Combine(dir.FullName, "ZB.MOM.WW.OtOpcUa.slnx")))
dir = dir.Parent;
dir.ShouldNotBeNull("Could not find solution root (ZB.MOM.WW.OtOpcUa.slnx).");
return Path.Combine(
dir!.FullName, "src", "Drivers", "Cli", "ZB.MOM.WW.OtOpcUa.Driver.S7.Cli", "Commands");
}
}

View File

@@ -0,0 +1,92 @@
using CliFx.Attributes;
using CliFx.Infrastructure;
using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Driver.S7.Cli;
using S7NetCpuType = global::S7.Net.CpuType;
namespace ZB.MOM.WW.OtOpcUa.Driver.S7.Cli.Tests;
/// <summary>
/// Covers <see cref="S7CommandBase.BuildOptions"/> — the pure, deterministic mapping
/// from the base's host/port/CPU/rack/slot/timeout flags onto an
/// <c>S7DriverOptions</c>. The CLI is one-shot so the background connectivity probe
/// must be disabled.
/// </summary>
[Trait("Category", "Unit")]
public sealed class S7CommandBaseBuildOptionsTests
{
// Test-only S7CommandBase concrete subclass that exposes the protected BuildOptions
// helper. The [Command] attribute is required by the CliFx analyzer
// (CliFx_CommandMustBeAnnotated) — this command is never registered with the CLI app
// but the analyzer rule fires for every ICommand implementor in the compilation.
[Command("noop-test", Description = "Test-only probe of S7CommandBase.BuildOptions.")]
private sealed class ProbeOnly : S7CommandBase
{
public override ValueTask ExecuteAsync(IConsole console) => default;
public S7DriverOptions Invoke(IReadOnlyList<S7TagDefinition> tags) => BuildOptions(tags);
}
[Fact]
public void BuildOptions_disables_probe_for_one_shot_cli_runs()
{
var sut = new ProbeOnly
{
Host = "10.0.0.5",
Port = 102,
CpuType = S7NetCpuType.S71500,
Rack = 0,
Slot = 0,
TimeoutMs = 5000,
};
var options = sut.Invoke([]);
options.Probe.ShouldNotBeNull();
options.Probe.Enabled.ShouldBeFalse();
}
[Fact]
public void BuildOptions_maps_TimeoutMs_to_Timeout_TimeSpan()
{
var sut = new ProbeOnly { Host = "h", TimeoutMs = 7500 };
var options = sut.Invoke([]);
options.Timeout.ShouldBe(TimeSpan.FromMilliseconds(7500));
}
[Fact]
public void BuildOptions_flows_host_port_cpu_rack_slot_through()
{
var sut = new ProbeOnly
{
Host = "plc.shop.local",
Port = 4102,
CpuType = S7NetCpuType.S7300,
Rack = 1,
Slot = 2,
TimeoutMs = 3000,
};
var options = sut.Invoke([]);
options.Host.ShouldBe("plc.shop.local");
options.Port.ShouldBe(4102);
options.CpuType.ShouldBe(S7NetCpuType.S7300);
options.Rack.ShouldBe((short)1);
options.Slot.ShouldBe((short)2);
}
[Fact]
public void BuildOptions_forwards_tag_list_verbatim()
{
var sut = new ProbeOnly { Host = "h" };
var tag = new S7TagDefinition("t", "MW0", S7DataType.Int16, Writable: false);
var options = sut.Invoke([tag]);
options.Tags.Count.ShouldBe(1);
options.Tags[0].ShouldBeSameAs(tag);
}
}

View File

@@ -0,0 +1,32 @@
using Shouldly;
using Xunit;
namespace ZB.MOM.WW.OtOpcUa.Driver.S7.Cli.Tests;
/// <summary>
/// Driver.S7.Cli-007: the S7 subscribe command — a near-verbatim copy of the Modbus
/// subscribe command — must keep the comment that explains why <c>OnDataChange</c>
/// uses <c>console.Output.WriteLine</c> (synchronous, on a driver background thread)
/// instead of <c>System.Console</c> or the async <c>WriteLineAsync</c>. The rationale
/// is non-obvious to a reader and the Modbus copy carries it; the S7 copy must too.
/// </summary>
[Trait("Category", "Unit")]
public sealed class SubscribeCommandConsoleHandlerCommentTests
{
[Fact]
public void SubscribeCommand_explains_why_OnDataChange_uses_console_Output_synchronously()
{
var dir = new DirectoryInfo(AppContext.BaseDirectory);
while (dir is not null && !File.Exists(Path.Combine(dir.FullName, "ZB.MOM.WW.OtOpcUa.slnx")))
dir = dir.Parent;
dir.ShouldNotBeNull();
var source = File.ReadAllText(Path.Combine(
dir!.FullName, "src", "Drivers", "Cli", "ZB.MOM.WW.OtOpcUa.Driver.S7.Cli",
"Commands", "SubscribeCommand.cs"));
// The comment must reference the CliFx console abstraction so future copy-pastes
// do not lose the rationale.
source.ShouldContain("CliFx console");
source.ShouldContain("IConsole");
}
}