docs(#655): history is server-side only; rewrite OPC-009 and stale driver-history references

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
This commit is contained in:
Joseph Doherty
2026-10-08 23:36:25 -04:00
parent f7f7d948cd
commit 67059e479f
21 changed files with 72 additions and 97 deletions
+4 -5
View File
@@ -9,10 +9,9 @@ OtOpcUa is a multi-driver OPC UA server. The Core (`ZB.MOM.WW.OtOpcUa.Core` + `C
- `IHostConnectivityProbe` — per-host reachability events
- `IPerCallHostResolver` — multi-host drivers that route each call to a target endpoint at dispatch time
- `IAlarmSource` — driver-emitted OPC UA A&C events
- `IHistoryProvider` — driver-side raw / processed / at-time / events HistoryRead (see [HistoricalDataAccess.md](../v1/HistoricalDataAccess.md))
- `IRediscoverable` — driver-initiated address-space rebuild notifications
- `ISkippedTagReporter` — authored tags the driver could not build into its poll table (see [Skipped tags](#skipped-tags) below)
- `IHistorianDataSource` — server-side historian read backend registration (the HistorianGateway backend), distinct from the driver-side `IHistoryProvider` HistoryRead path
- `IHistorianDataSource` — server-side historian read backend registration (the HistorianGateway backend) (drivers carry no history capability; Gitea #655)
Each driver opts into only the capabilities it supports. Every async capability call at the Server dispatch layer goes through `CapabilityInvoker` (`Core/Resilience/CapabilityInvoker.cs`), which wraps it in a Polly pipeline keyed on `(DriverInstanceId, HostName, DriverCapability)`. The `OTOPCUA0001` analyzer enforces the wrap at build time. Drivers themselves never depend on Polly; they just implement the capability interface and let the Core wrap it.
@@ -71,7 +70,7 @@ Three properties worth knowing:
| [AB Legacy](AbLegacy.md) | `Driver.AbLegacy` | A | libplctag PCCC | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | SLC 500 / MicroLogix. File-based addressing (`N7:0`, `F8:0`) — no symbol table, tag list is user-authored in the config DB |
| [TwinCAT](TwinCAT.md) | `Driver.TwinCAT` | B | Beckhoff `TwinCAT.Ads` (`TcAdsClient`) | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IRediscoverable | The only native-notification driver outside Galaxy — ADS delivers `ValueChangedCallback` events the driver forwards straight to `ISubscribable.OnDataChange` without polling. Symbol tree uploaded via `SymbolLoaderFactory` |
| [FOCAS](FOCAS.md) | `Driver.FOCAS` | A | Pure-managed `FocasWireClient` — FOCAS/2 Ethernet binary protocol on TCP:8193, inlined into the driver assembly | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IAlarmSource | `IWritable` is implemented but read-only by design — `WriteAsync` returns `BadNotWritable` for every point. CNC-shaped data model (axes, spindle, PMC, macros, alarms) not a flat tag map. Previously Tier-C (Host + P/Invoke + shim DLL); retired in the 2026-04-24 migration when the managed wire client landed |
| [OPC UA Client](OpcUaClient.md) | `Driver.OpcUaClient` | B | OPCFoundation `Opc.Ua.Client` | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IHistoryProvider, IHostConnectivityProbe | Gateway/aggregation driver — the only driver implementing driver-side `IHistoryProvider` (forwards HistoryRead to the upstream server). Opens a single `Session` against a remote OPC UA server and re-exposes its address space. Owns its own `ApplicationConfiguration` (distinct from `Client.Shared`) because it's always-on with keep-alive + `TransferSubscriptions` across SDK reconnect, not an interactive CLI |
| [OPC UA Client](OpcUaClient.md) | `Driver.OpcUaClient` | B | OPCFoundation `Opc.Ua.Client` | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IHostConnectivityProbe | Gateway/aggregation driver — does not proxy upstream history (no driver has a history capability). Opens a single `Session` against a remote OPC UA server and re-exposes its address space. Owns its own `ApplicationConfiguration` (distinct from `Client.Shared`) because it's always-on with keep-alive + `TransferSubscriptions` across SDK reconnect, not an interactive CLI |
| [MQTT](Mqtt.md) | `Driver.Mqtt` (+ `.Browser`, `.Contracts`) | A | [MQTTnet 5](https://github.com/dotnet/MQTTnet) | IDriver, ITagDiscovery, IReadable, ISubscribable, IHostConnectivityProbe, IRediscoverable | **Push, not poll, and read-only** — the broker delivers PUBLISH frames the driver forwards straight to `ISubscribable.OnDataChange`; `IReadable` serves the last retained/received value from cache, and there is **no `IWritable`** (nothing publishes back). Subscriptions are indexed **by topic filter, not by topic**, so wildcard tags survive a reconnect. A rejected CONNACK throws `MqttConnectRejectedException`: unrecoverable codes → `Faulted` + supervisor stop, transient → retry. **Two modes:** `Plain` binds a tag to a concrete topic + JSON path; `SparkplugB` decodes vendored Eclipse-Tahu protobuf under one `spBv1.0/{groupId}/#` subscription and binds by the `group/edgeNode/device?/metric` tuple (birth/alias/seq-gap state machine, death→STALE, scoped rebirth NCMD). `IRediscoverable` fires on a DBIRTH but is **inert platform-side** — see [#507](https://gitea.dohertylan.com/dohertj2/lmxopcua/issues/507) |
| [MTConnect](MTConnect.md) | `Driver.MTConnect` (+ `.Contracts`) | — | Hand-rolled `System.Xml.Linq` HTTP/XML client against a vendor-neutral MTConnect Agent (`/probe`, `/current`, `/sample`) — no TrakHound dependency (dropped; see the driver doc) | IDriver, ITagDiscovery, IReadable, ISubscribable, IHostConnectivityProbe, IRediscoverable | Read-only by design (no `IWritable`). Production data plane is entirely `ISubscribable`/`OnDataChange` — `IReadable` is CLI/test-only. Browse is free via the Wave-0 universal discovery browser, no bespoke browser project. `IRediscoverable`/`IHostConnectivityProbe` have no server-side consumer yet — a pre-existing fleet-wide gap, not MTConnect-specific |
| [Sql](Sql.md) | `Driver.Sql` (+ `.Browser`, `.Contracts`) | A | `Microsoft.Data.SqlClient` behind an `ISqlDialect` seam (`SqlServerDialect` shipped; Postgres/ODBC deferred) | IDriver, ITagDiscovery, IReadable, ISubscribable, IHostConnectivityProbe | Read-only DB-poll driver with a bespoke schema browser. **Credentials are never persisted** — the deploy gate rejects a stored `connectionString` (#498) and catalog identifiers are validated against the live catalog's own spelling (#496). `SupportsOnlineDiscovery => false` by design (the bespoke browser wins). `SqlTagModel.Query` is deferred to P3 and rejected end-to-end by parser, validator, planner and editor. Merged `4ad54037` |
@@ -93,7 +92,7 @@ Three properties worth knowing:
- [AbLegacy.md](AbLegacy.md) — AB Legacy PCCC driver (SLC 500 / MicroLogix / PLC-5): file-based addressing, user-authored tag list
- [S7.md](S7.md) — Siemens S7 driver (S7-300/400/1200/1500 + S7-200): getting started, config, data-block addressing, serialized single-connection model
- [TwinCAT.md](TwinCAT.md) — Beckhoff TwinCAT (ADS) driver: getting started, native-notification subscription, symbol-tree upload
- [OpcUaClient.md](OpcUaClient.md) — OPC UA Client (gateway/aggregation) driver: remote-server session, driver-side HistoryRead forwarding, reconnect behaviour
- [OpcUaClient.md](OpcUaClient.md) — OPC UA Client (gateway/aggregation) driver: remote-server session, reconnect behaviour
- [Mqtt.md](Mqtt.md) — MQTT broker-subscribe driver: broker/TLS/auth config, topic + JSON-path tag binding, retained-value seeding, `#`-observation browser, CONNACK-rejection semantics, **Sparkplug B** (birth/alias/seq/rebirth state machine, birth-driven browse picker, death→STALE), and the **Known gaps** table
- **MTConnect** has a short getting-started doc because the hand-rolled-vs-TrakHound divergence, the
@@ -122,7 +121,7 @@ Each driver has a dedicated fixture doc that lays out what the integration / uni
## Related cross-driver docs
- [HistoricalDataAccess.md](../v1/HistoricalDataAccess.md) — `IHistoryProvider` dispatch, aggregate mapping, continuation points. The OPC UA Client driver is the only driver that implements driver-side `IHistoryProvider` (it forwards HistoryRead to the upstream server); the AVEVA Historian path is served server-side by the HistorianGateway-backed `IHistorianDataSource` instead. Other drivers do not implement the interface and return `BadHistoryOperationUnsupported`.
- [HistoricalDataAccess.md](../v1/HistoricalDataAccess.md) — v1 archive of the retired per-driver history design (aggregate mapping, continuation points). History is now served only by the server-side `IHistorianDataSource` (HistorianGateway); no driver implements a history capability, and nodes without `isHistorized` return `BadHistoryOperationUnsupported`.
- [AlarmTracking.md](../AlarmTracking.md) — `IAlarmSource` event model and filtering. Implemented by Galaxy (native MxAccess alarms, working end-to-end), OPC UA Client, AB CIP, and FOCAS; AB Legacy, Modbus, S7, TwinCAT, and MQTT have no alarm source.
- [Subscriptions.md](../v1/Subscriptions.md) — how the Server multiplexes subscriptions onto `ISubscribable.OnDataChange`.
- [docs/v2/driver-stability.md](../v2/driver-stability.md) — historical design record of the A / B / C tier model. Only `DriverTier` + the `CapabilityPolicy` defaults per tier × capability (`DriverResilienceOptions.GetTierDefaults`) are live; its `MemoryTracking` / recycle / out-of-process isolation machinery was deleted (#522) and every driver runs Tier A.