Dockerize Modbus + AB CIP + S7 test fixtures for reproducibility. Every driver integration simulator now has a pinned Docker image alongside the existing native launcher — Docker is the primary path, native fallbacks kept for contributors who prefer them. Matches the already-Dockerized OpcUaClient/opc-plc pattern from #215 so every fixture in the fleet presents the same compose-up/test/compose-down loop. Reproducibility gain: what used to require a local pip/Python install (Modbus pymodbus, S7 python-snap7) or a per-OS C build from source (AB CIP ab_server from libplctag) now collapses to a Dockerfile + docker compose up. Modbus — new tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Docker/ with Dockerfile (python:3.12-slim-bookworm + pymodbus[simulator]==3.13.0) + docker-compose.yml with four compose profiles (standard / dl205 / mitsubishi / s7_1500) backed by the existing profile JSONs copied under Docker/profiles/ as canonical; native fallback in Pymodbus/ retained with the same JSON set (symlink-equivalent — manual re-sync when profiles change, noted in both READMEs). Port 5020 unchanged so MODBUS_SIM_ENDPOINT + ModbusSimulatorFixture work without code change. Dropped the --no_http CLI arg the old serve.ps1 + compose draft passed — pymodbus 3.13 doesn't recognize it; the simulator's http ui just binds inside the container where nothing maps it out and costs nothing. S7 — new tests/ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests/Docker/ with Dockerfile (python:3.12-slim-bookworm + python-snap7>=2.0) + docker-compose.yml with one s7_1500 compose profile; copies the existing server.py shim + s7_1500.json seed profile; runs python -u server.py ... --port 1102. Native fallback in PythonSnap7/ retained. Port 1102 unchanged. AB CIP — hardest because ab_server is a source-only C tool in libplctag's src/tools/ab_server/. New tests/ZB.MOM.WW.OtOpcUa.Driver.AbCip.IntegrationTests/Docker/ Dockerfile is multi-stage: build stage (debian:bookworm-slim + build-essential + cmake) clones libplctag at a pinned tag + cmake --build build --target ab_server; runtime stage (debian:bookworm-slim) copies just the binary from /src/build/bin_dist/ab_server. docker-compose.yml ships four compose profiles (controllogix / compactlogix / micro800 / guardlogix) with per-family ab_server CLI args matching AbServerProfile.cs. AbServerFixture updated: tries TCP probe on 127.0.0.1:44818 first (Docker path) + spawns the native binary only as fallback when no listener is there. AB_SERVER_ENDPOINT env var supported for pointing at a real PLC. AbServerFact/Theory attributes updated to IsServerAvailable() which accepts any of: live listener on 44818, AB_SERVER_ENDPOINT set, or binary on PATH. Required two CLI-compat fixes to ab_server's argument expectations that the existing native profile never caught because it was never actually run at CI: --plc is case-sensitive (ControlLogix not controllogix), CIP tags need [size] bracket notation (DINT[1] not bare DINT), ControlLogix also requires --path=1,0. Compose files carry the corrected flags; the existing native-path AbServerProfile.cs was never invoked in practice so we don't rewrite it here. Micro800 now uses the --plc=Micro800 mode rather than falling back to ControlLogix emulation — ab_server does have the dedicated mode, the old Notes saying otherwise were wrong. Updated docs: three fixture coverage docs (Modbus-Test-Fixture.md, S7-Test-Fixture.md, AbServer-Test-Fixture.md) flip their "What the fixture is" section from native-only to Docker-primary-with-native-fallback; dev-environment.md §Resource Inventory replaces the old ambiguous "Docker Desktop + ab_server native" mix with four per-driver rows (each listing the image, compose file, compose profiles, port, credentials) + a new Docker fixtures — quick reference subsection giving the one-line docker compose -f <…> --profile <…> up for each driver + the env-var override names + the native fallback install recipes. drivers/README.md coverage map table updated — Modbus/AB CIP/S7 entries now read "Dockerized …" consistent with OpcUaClient's line. Verified end-to-end against live containers: Modbus DL205 smoke 1/1, S7 3/3, AB CIP ControlLogix 4/4 (all family theory rows). Container lifecycle clean (up/test/down, no leaked state). Every fixture keeps its skip-when-absent probe + env-var endpoint override so dotnet test on a fresh clone without Docker running still gets a green run.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
Joseph Doherty
2026-04-20 12:09:44 -04:00
parent 3b3e814855
commit 6609141493
24 changed files with 1258 additions and 38 deletions

View File

@@ -10,19 +10,27 @@ quirk. UDT / alarm / quirk behavior is verified only by unit tests with
## What the fixture is
- **Binary**: `ab_server` / `ab_server.exe` from libplctag
([libplctag/libplctag](https://github.com/libplctag/libplctag) +
[kyle-github/ab_server](https://github.com/kyle-github/ab_server), MIT).
Resolved off `PATH` by `AbServerFixture.LocateBinary`; tests skip via
`[AbServerFact]` / `[AbServerTheory]` when missing.
- **Lifecycle**: `AbServerFixture` (`tests/ZB.MOM.WW.OtOpcUa.Driver.AbCip.IntegrationTests/AbServerFixture.cs`)
starts the simulator with a profile-specific `--plc` arg + `--tag` seeds,
waits ~500 ms, kills on `DisposeAsync`.
- **Binary**: `ab_server` — a C program in libplctag's
`src/tools/ab_server/` ([libplctag/libplctag](https://github.com/libplctag/libplctag),
MIT).
- **Primary launcher**: Docker. `Docker/Dockerfile` multi-stage-builds
`ab_server` from source against a pinned libplctag tag + copies the
binary into a slim runtime image. `Docker/docker-compose.yml` has
per-family services (`controllogix` / `compactlogix` / `micro800` /
`guardlogix`); all bind `:44818`.
- **Lifecycle**: `AbServerFixture` probes `127.0.0.1:44818` at collection
init. When a Docker container is running (or `AB_SERVER_ENDPOINT` is
set) the fixture skips its legacy spawn path + the tests dial the
running container. When neither is present, it falls back to the
pre-Docker path of resolving `ab_server` off `PATH` + spawning it.
- **Profiles**: `KnownProfiles.{ControlLogix, CompactLogix, Micro800, GuardLogix}`
in `AbServerProfile.cs`. Each composes a CLI arg list + seed-tag set; their
own `Notes` fields document the quirks called out below.
in `AbServerProfile.cs`. Each composes a CLI arg list + seed-tag set; the
`Docker/docker-compose.yml` `command:` entries mirror those args 1:1.
- **Tests**: one smoke, `AbCipReadSmokeTests.Driver_reads_seeded_DInt_from_ab_server`,
parametrized over all four profiles.
parametrized over all four profiles via `[AbServerTheory]` + `[MemberData]`.
- **Skip rules** via `[AbServerFact]` / `[AbServerTheory]`: accept a live
listener on `:44818` (Docker), an `AB_SERVER_ENDPOINT` override, or the
native binary on `PATH`; skip otherwise.
## What it actually covers

View File

@@ -11,14 +11,20 @@ shaped (neither is a Modbus-side concept).
## What the fixture is
- **Simulator**: `pymodbus` (Python, BSD) driven from PowerShell + per-family
JSON profiles under
`tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Pymodbus/`.
- **Simulator**: `pymodbus` (Python, BSD) — primary launcher is a pinned
Docker image at
`tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Docker/`.
Native-Python fallback under `Pymodbus/` is kept for contributors who
don't want Docker.
- **Lifecycle**: `ModbusSimulatorFixture` (collection-scoped) TCP-probes
`localhost:5020` on first use. `MODBUS_SIM_ENDPOINT` env var overrides the
endpoint so the same suite can target a real PLC.
- **Profiles**: `DL205Profile`, `MitsubishiProfile`, `S7_1500Profile`
each composes device-specific register-format + quirk-seed JSON for pymodbus.
Profile JSONs are canonical under `Docker/profiles/`; `Pymodbus/` carries
a copy for the native fallback.
- **Compose services**: one per profile (`standard` / `dl205` /
`mitsubishi` / `s7_1500`); only one binds `:5020` at a time.
- **Tests skip** via `Assert.Skip(sim.SkipReason)` when the probe fails; no
custom FactAttribute needed because `ModbusSimulatorCollection` carries the
skip reason.

View File

@@ -41,9 +41,9 @@ Driver type metadata is registered at startup in `DriverTypeRegistry` (`src/ZB.M
Each driver has a dedicated fixture doc that lays out what the integration / unit harness actually covers vs. what's trusted from field deployments. Read the relevant one before claiming "green suite = production-ready" for a driver.
- [AB CIP](AbServer-Test-Fixture.md) — `ab_server` simulator, atomic-read smoke only; UDT / ALMD / family quirks are unit-only
- [Modbus](Modbus-Test-Fixture.md) — `pymodbus` + per-family profiles; best-covered driver, gaps are error-path-shaped
- [Siemens S7](S7-Test-Fixture.md) — no integration fixture, unit-only via fake `IS7Client`
- [AB CIP](AbServer-Test-Fixture.md) — Dockerized `ab_server` (multi-stage build from libplctag source); atomic-read smoke across 4 families; UDT / ALMD / family quirks unit-only
- [Modbus](Modbus-Test-Fixture.md) — Dockerized `pymodbus` + per-family JSON profiles (4 compose profiles); best-covered driver, gaps are error-path-shaped
- [Siemens S7](S7-Test-Fixture.md) — Dockerized `python-snap7` server; DB/MB read + write round-trip verified end-to-end on `:1102`
- [AB Legacy](AbLegacy-Test-Fixture.md) — no integration fixture, unit-only via `FakeAbLegacyTag` (libplctag PCCC)
- [TwinCAT](TwinCAT-Test-Fixture.md) — no integration fixture, unit-only via `FakeTwinCATClient` with native-notification harness
- [FOCAS](FOCAS-Test-Fixture.md) — no integration fixture, unit-only via `FakeFocasClient`; Tier C out-of-process isolation scoped but not shipped

View File

@@ -15,12 +15,14 @@ session types, PUT/GET-disabled enforcement — all need real hardware.
**Integration layer** (task #216):
`tests/ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests/` stands up a
python-snap7 `Server` via `PythonSnap7/serve.ps1 -Profile s7_1500` on
`localhost:1102`. `Snap7ServerFixture` probes the port at collection init
+ skips with a clear message when unreachable (matches the pymodbus
pattern). `server.py` reads a JSON profile + seeds DB/MB bytes at declared
offsets; seeds are typed (`u16` / `i16` / `i32` / `f32` / `bool` / `ascii`
for S7 STRING).
python-snap7 `Server` via `Docker/docker-compose.yml --profile s7_1500`
on `localhost:1102` (pinned `python:3.12-slim-bookworm` base +
`python-snap7>=2.0`). Native-Python fallback under `PythonSnap7/` kept
for contributors who prefer to avoid Docker. `Snap7ServerFixture` probes
the port at collection init + skips with a clear message when unreachable
(matches the pymodbus pattern). `server.py` reads a JSON profile + seeds
DB/MB bytes at declared offsets; seeds are typed (`u16` / `i16` / `i32` /
`f32` / `bool` / `ascii` for S7 STRING).
**Unit layer**: `tests/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests/` covers
everything the wire-level suite doesn't — address parsing, error