Auto: s7-c1 — surface negotiated PDU size via DriverHealth.Diagnostics
Closes #294
This commit is contained in:
@@ -0,0 +1,54 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.S7.Tests;
|
||||
|
||||
/// <summary>
|
||||
/// Unit-level coverage for the <c>DriverHealth.Diagnostics</c> dictionary the S7 driver
|
||||
/// exposes through <see cref="S7Driver.GetHealth"/>. Wire-level reads of
|
||||
/// <c>S7.NegotiatedPduSize</c> against a real handshake live in the Snap7 integration
|
||||
/// suite (where the simulator negotiates a fixed 240-byte PDU); this suite covers the
|
||||
/// before-connect / after-shutdown contract on the same key without booting a fixture.
|
||||
/// </summary>
|
||||
[Trait("Category", "Unit")]
|
||||
public sealed class S7DriverDiagnosticsTests
|
||||
{
|
||||
[Fact]
|
||||
public void NegotiatedPduSize_diagnostics_key_starts_at_zero_before_initialize()
|
||||
{
|
||||
// Before InitializeAsync the driver hasn't talked to a PLC, so the negotiated PDU
|
||||
// is unknown. We surface 0 (rather than omitting the key) so the Admin UI driver-
|
||||
// diagnostics panel can render a stable row even pre-connect — operators see "0"
|
||||
// and immediately know the driver hasn't completed a handshake yet.
|
||||
using var drv = new S7Driver(new S7DriverOptions { Host = "192.0.2.1" }, "s7-pre-init");
|
||||
|
||||
var health = drv.GetHealth();
|
||||
// Pre-init the driver's state is Unknown and Diagnostics is null (the empty dict);
|
||||
// the field-backed counter is what we directly assert here.
|
||||
drv.NegotiatedPduSize.ShouldBe(0);
|
||||
// The DriverHealth surface should also be safe to consume.
|
||||
health.DiagnosticsOrEmpty.ContainsKey("S7.NegotiatedPduSize").ShouldBeFalse(
|
||||
"pre-init Diagnostics is null and DiagnosticsOrEmpty returns the empty dict");
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task NegotiatedPduSize_resets_to_zero_after_shutdown()
|
||||
{
|
||||
// Even when InitializeAsync fails (unreachable host), the field must remain at 0
|
||||
// so a subsequent ShutdownAsync doesn't carry a stale value forward into the next
|
||||
// re-init attempt. RFC 5737 documentation IP guarantees a fast TCP timeout.
|
||||
var opts = new S7DriverOptions { Host = "192.0.2.1", Timeout = TimeSpan.FromMilliseconds(250) };
|
||||
using var drv = new S7Driver(opts, "s7-shutdown");
|
||||
|
||||
await Should.ThrowAsync<Exception>(async () =>
|
||||
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken));
|
||||
|
||||
// The Faulted path in InitializeAsync's catch block doesn't touch _negotiatedPduSize
|
||||
// (we never reached the post-OpenAsync capture) so it should still be 0.
|
||||
drv.NegotiatedPduSize.ShouldBe(0);
|
||||
|
||||
await drv.ShutdownAsync(TestContext.Current.CancellationToken);
|
||||
drv.NegotiatedPduSize.ShouldBe(0, "ShutdownAsync must zero the negotiated PDU snapshot");
|
||||
}
|
||||
}
|
||||
Reference in New Issue