test(modbus-rtu): add rtu_over_tcp pymodbus fixture + RTU-over-TCP integration tests

Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
This commit is contained in:
Joseph Doherty
2026-07-24 14:29:10 -04:00
parent 132e7b63f6
commit 650e27075f
4 changed files with 297 additions and 0 deletions
@@ -78,6 +78,30 @@ services:
"--json_file", "/fixtures/s7_1500.json" "--json_file", "/fixtures/s7_1500.json"
] ]
# RTU-over-TCP profile. Same pymodbus simulator, but the server is framed
# RTU (framer=rtu) instead of socket/MBAP — this is what a serial→Ethernet
# gateway presents. Binds :5021 (NOT the shared :5020) so it co-runs with
# the `standard` profile: two families, two ports, no conflict. Serves
# rtu_over_tcp.json (byte-for-byte standard.json + framer/port swap).
rtu_over_tcp:
profiles: ["rtu_over_tcp"]
image: otopcua-pymodbus:3.13.0
build:
context: .
dockerfile: Dockerfile
container_name: otopcua-pymodbus-rtu_over_tcp
labels:
project: lmxopcua
restart: "no"
ports:
- "5021:5021"
command: [
"pymodbus.simulator",
"--modbus_server", "srv",
"--modbus_device", "dev",
"--json_file", "/fixtures/rtu_over_tcp.json"
]
# Exception-injection profile. Runs the standalone pure-stdlib Modbus/TCP # Exception-injection profile. Runs the standalone pure-stdlib Modbus/TCP
# server shipped as exception_injector.py instead of the pymodbus # server shipped as exception_injector.py instead of the pymodbus
# simulator — pymodbus naturally emits only exception codes 02 + 03, and # simulator — pymodbus naturally emits only exception codes 02 + 03, and
@@ -0,0 +1,97 @@
{
"_comment": "rtu_over_tcp.json — RTU-over-TCP Modbus server for the integration suite (RTU framing tunnelled over a socket, as a serial→Ethernet gateway presents it). Byte-for-byte standard.json EXCEPT the server block: framer=\"rtu\" (not \"socket\") + port 5021 (not 5020), so it co-runs with the standard profile on :5020. pymodbus 3.13's simulator honors framer=rtu on a TCP server — confirmed on the wire (controller spike, 2026-07-24): raw RTU FC03 read of HR[5] returned `01 03 02 00 05 78 47`, a pure RTU frame with no MBAP header. Layout is identical to standard.json: HR[0..31]=address-as-value, HR[100]=auto-increment, HR[200..209]=scratch, coils 1024..1055=alternating, coils 1100..1109=scratch. NOTE: pymodbus rejects unknown keys at device-list / setup level; explanatory comments live in the README + git history.",
"server_list": {
"srv": {
"comm": "tcp",
"host": "0.0.0.0",
"port": 5021,
"framer": "rtu",
"device_id": 1
}
},
"device_list": {
"dev": {
"setup": {
"co size": 2048,
"di size": 2048,
"hr size": 2048,
"ir size": 2048,
"shared blocks": true,
"type exception": false,
"defaults": {
"value": {"bits": 0, "uint16": 0, "uint32": 0, "float32": 0.0, "string": " "},
"action": {"bits": null, "uint16": null, "uint32": null, "float32": null, "string": null}
}
},
"invalid": [],
"write": [
[0, 31],
[100, 100],
[200, 209],
[1024, 1055],
[1100, 1109]
],
"uint16": [
{"addr": 0, "value": 0}, {"addr": 1, "value": 1},
{"addr": 2, "value": 2}, {"addr": 3, "value": 3},
{"addr": 4, "value": 4}, {"addr": 5, "value": 5},
{"addr": 6, "value": 6}, {"addr": 7, "value": 7},
{"addr": 8, "value": 8}, {"addr": 9, "value": 9},
{"addr": 10, "value": 10}, {"addr": 11, "value": 11},
{"addr": 12, "value": 12}, {"addr": 13, "value": 13},
{"addr": 14, "value": 14}, {"addr": 15, "value": 15},
{"addr": 16, "value": 16}, {"addr": 17, "value": 17},
{"addr": 18, "value": 18}, {"addr": 19, "value": 19},
{"addr": 20, "value": 20}, {"addr": 21, "value": 21},
{"addr": 22, "value": 22}, {"addr": 23, "value": 23},
{"addr": 24, "value": 24}, {"addr": 25, "value": 25},
{"addr": 26, "value": 26}, {"addr": 27, "value": 27},
{"addr": 28, "value": 28}, {"addr": 29, "value": 29},
{"addr": 30, "value": 30}, {"addr": 31, "value": 31},
{"addr": 100, "value": 0,
"action": "increment",
"parameters": {"minval": 0, "maxval": 65535}},
{"addr": 200, "value": 0}, {"addr": 201, "value": 0},
{"addr": 202, "value": 0}, {"addr": 203, "value": 0},
{"addr": 204, "value": 0}, {"addr": 205, "value": 0},
{"addr": 206, "value": 0}, {"addr": 207, "value": 0},
{"addr": 208, "value": 0}, {"addr": 209, "value": 0}
],
"bits": [
{"addr": 1024, "value": 1}, {"addr": 1025, "value": 0},
{"addr": 1026, "value": 1}, {"addr": 1027, "value": 0},
{"addr": 1028, "value": 1}, {"addr": 1029, "value": 0},
{"addr": 1030, "value": 1}, {"addr": 1031, "value": 0},
{"addr": 1032, "value": 1}, {"addr": 1033, "value": 0},
{"addr": 1034, "value": 1}, {"addr": 1035, "value": 0},
{"addr": 1036, "value": 1}, {"addr": 1037, "value": 0},
{"addr": 1038, "value": 1}, {"addr": 1039, "value": 0},
{"addr": 1040, "value": 1}, {"addr": 1041, "value": 0},
{"addr": 1042, "value": 1}, {"addr": 1043, "value": 0},
{"addr": 1044, "value": 1}, {"addr": 1045, "value": 0},
{"addr": 1046, "value": 1}, {"addr": 1047, "value": 0},
{"addr": 1048, "value": 1}, {"addr": 1049, "value": 0},
{"addr": 1050, "value": 1}, {"addr": 1051, "value": 0},
{"addr": 1052, "value": 1}, {"addr": 1053, "value": 0},
{"addr": 1054, "value": 1}, {"addr": 1055, "value": 0},
{"addr": 1100, "value": 0}, {"addr": 1101, "value": 0},
{"addr": 1102, "value": 0}, {"addr": 1103, "value": 0},
{"addr": 1104, "value": 0}, {"addr": 1105, "value": 0},
{"addr": 1106, "value": 0}, {"addr": 1107, "value": 0},
{"addr": 1108, "value": 0}, {"addr": 1109, "value": 0}
],
"uint32": [],
"float32": [],
"string": [],
"repeat": []
}
}
}
@@ -0,0 +1,82 @@
using System.Net.Sockets;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests;
/// <summary>
/// Reachability probe for the RTU-over-TCP Modbus simulator (pymodbus in Docker with
/// <c>framer=rtu</c>, see <c>Docker/docker-compose.yml</c> profile <c>rtu_over_tcp</c>) or a
/// real serial→Ethernet Modbus gateway. Mirrors <see cref="ModbusSimulatorFixture"/> but reads
/// <c>MODBUS_RTU_SIM_ENDPOINT</c> (default <c>10.100.0.35:5021</c> — the shared Docker host, a
/// distinct port from the standard profile's <c>:5020</c> so the two fixtures co-run). TCP-connects
/// once at fixture construction; each test checks <see cref="SkipReason"/> and calls
/// <c>Assert.Skip</c> when the endpoint was unreachable, so a dev box without a running simulator
/// still passes `dotnet test` cleanly.
/// </summary>
/// <remarks>
/// Same one-shot-probe discipline as <see cref="ModbusSimulatorFixture"/>: the probe socket is
/// not held for the life of the fixture (tests open their own <see cref="ModbusRtuOverTcpTransport"/>
/// against the same endpoint), and the fixture is a collection fixture so the probe runs once per
/// session rather than per test.
/// </remarks>
public sealed class ModbusRtuOverTcpFixture : IAsyncDisposable
{
// :5021 (not the standard profile's :5020) so the rtu_over_tcp container can co-run with the
// standard container on the shared Docker host. 10.100.0.35 = the shared Docker host (see
// CLAUDE.md "Docker Workflow"). Override with MODBUS_RTU_SIM_ENDPOINT to point at a real
// serial→Ethernet Modbus gateway, or a locally-running container.
private const string DefaultEndpoint = "10.100.0.35:5021";
private const string EndpointEnvVar = "MODBUS_RTU_SIM_ENDPOINT";
/// <summary>Gets the host address of the RTU-over-TCP Modbus simulator.</summary>
public string Host { get; }
/// <summary>Gets the port of the RTU-over-TCP Modbus simulator.</summary>
public int Port { get; }
/// <summary>Gets the skip reason if the simulator is unreachable; otherwise null.</summary>
public string? SkipReason { get; }
/// <summary>Initializes a new instance of the <see cref="ModbusRtuOverTcpFixture"/> class.</summary>
public ModbusRtuOverTcpFixture()
{
var raw = Environment.GetEnvironmentVariable(EndpointEnvVar) ?? DefaultEndpoint;
var parts = raw.Split(':', 2);
Host = parts[0];
Port = parts.Length == 2 && int.TryParse(parts[1], out var p) ? p : 502;
try
{
// Force IPv4 on the probe — pymodbus binds 0.0.0.0 (IPv4 only) while .NET default-resolves
// "localhost" → IPv6 ::1 first and only then tries IPv4, surfacing as a 2s timeout under
// .NET 10. Resolving + dialing explicit IPv4 sidesteps the dual-stack ordering. (Same
// rationale as ModbusSimulatorFixture.)
using var client = new TcpClient(System.Net.Sockets.AddressFamily.InterNetwork);
var task = client.ConnectAsync(
System.Net.Dns.GetHostAddresses(Host)
.FirstOrDefault(a => a.AddressFamily == System.Net.Sockets.AddressFamily.InterNetwork)
?? System.Net.IPAddress.Loopback,
Port);
if (!task.Wait(TimeSpan.FromSeconds(2)) || !client.Connected)
{
SkipReason = $"RTU-over-TCP Modbus simulator at {Host}:{Port} did not accept a TCP connection within 2s. " +
$"Start the pymodbus Docker container (docker compose -f Docker/docker-compose.yml --profile rtu_over_tcp up -d --build) " +
$"or override {EndpointEnvVar}, then re-run.";
}
}
catch (Exception ex)
{
SkipReason = $"RTU-over-TCP Modbus simulator at {Host}:{Port} unreachable: {ex.GetType().Name}: {ex.Message}. " +
$"Start the pymodbus Docker container (docker compose -f Docker/docker-compose.yml --profile rtu_over_tcp up -d --build) " +
$"or override {EndpointEnvVar}, then re-run.";
}
}
/// <inheritdoc />
public ValueTask DisposeAsync() => ValueTask.CompletedTask;
}
[Xunit.CollectionDefinition(Name)]
public sealed class ModbusRtuOverTcpCollection : Xunit.ICollectionFixture<ModbusRtuOverTcpFixture>
{
public const string Name = "ModbusRtuOverTcp";
}
@@ -0,0 +1,94 @@
using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests;
/// <summary>
/// End-to-end round-trip against the <c>rtu_over_tcp.json</c> pymodbus profile (or a real
/// serial→Ethernet Modbus gateway when <c>MODBUS_RTU_SIM_ENDPOINT</c> points at one), driving the
/// full <see cref="ModbusDriver"/> + real <see cref="ModbusRtuOverTcpTransport"/> stack with
/// <see cref="ModbusTransportMode.RtuOverTcp"/>. Proves the driver reads a seeded holding register
/// and writes+reads-back a scratch register when the wire carries RTU framing
/// (<c>[addr][PDU][CRC-16]</c>, no MBAP header) rather than Modbus/TCP.
/// </summary>
/// <remarks>
/// pymodbus 3.13's simulator honors <c>framer=rtu</c> on a TCP server — confirmed on the wire
/// (controller spike, 2026-07-24): a raw RTU FC03 read of HR[5] returned
/// <c>01 03 02 00 05 78 47</c>, a pure RTU frame with no MBAP header (data 0x0005 = 5). So the
/// fixture is the plain pymodbus simulator with framer/port swapped — no stdlib fallback server.
/// </remarks>
[Collection(ModbusRtuOverTcpCollection.Name)]
[Trait("Category", "Integration")]
[Trait("Device", "RtuOverTcp")]
public sealed class ModbusRtuOverTcpTests(ModbusRtuOverTcpFixture sim)
{
/// <summary>Reads a seeded holding register (HR[5]=5) over RTU-over-TCP framing.</summary>
[Fact]
public async Task Reads_a_seeded_holding_register_over_rtu_framing()
{
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
var opts = new ModbusDriverOptions
{
Host = sim.Host,
Port = sim.Port,
UnitId = 1,
Transport = ModbusTransportMode.RtuOverTcp,
Timeout = TimeSpan.FromSeconds(2),
Probe = new ModbusProbeOptions { Enabled = false },
RawTags = ModbusRawTags.Entries([
new ModbusTagDefinition(
Name: "HR5",
Region: ModbusRegion.HoldingRegisters,
Address: 5,
DataType: ModbusDataType.UInt16,
Writable: false),
]),
};
await using var driver = new ModbusDriver(opts, driverInstanceId: "modbus-rtu-int");
await driver.InitializeAsync(driverConfigJson: "{}", TestContext.Current.CancellationToken);
var results = await driver.ReadAsync(["HR5"], TestContext.Current.CancellationToken);
results.Count.ShouldBe(1);
results[0].StatusCode.ShouldBe(0u); // Good
results[0].Value.ShouldBe((ushort)5); // HR[5] seeded = address-as-value
}
/// <summary>Writes then reads back a scratch holding register (HR[200]) over RTU-over-TCP framing.</summary>
[Fact]
public async Task Writes_and_reads_back_a_holding_register_over_rtu_framing()
{
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
var opts = new ModbusDriverOptions
{
Host = sim.Host,
Port = sim.Port,
UnitId = 1,
Transport = ModbusTransportMode.RtuOverTcp,
Timeout = TimeSpan.FromSeconds(2),
Probe = new ModbusProbeOptions { Enabled = false },
RawTags = ModbusRawTags.Entries([
new ModbusTagDefinition(
Name: "HR200",
Region: ModbusRegion.HoldingRegisters,
Address: 200,
DataType: ModbusDataType.UInt16,
Writable: true),
]),
};
await using var driver = new ModbusDriver(opts, driverInstanceId: "modbus-rtu-int-w");
await driver.InitializeAsync(driverConfigJson: "{}", TestContext.Current.CancellationToken);
var writes = await driver.WriteAsync(
[new WriteRequest("HR200", (ushort)4242)],
TestContext.Current.CancellationToken);
writes.Count.ShouldBe(1);
writes[0].StatusCode.ShouldBe(0u);
var back = await driver.ReadAsync(["HR200"], TestContext.Current.CancellationToken);
back.Count.ShouldBe(1);
back[0].StatusCode.ShouldBe(0u);
back[0].Value.ShouldBe((ushort)4242);
}
}