@@ -43,3 +43,41 @@ services:
|
||||
timeout: 2s
|
||||
retries: 10
|
||||
start_period: 10s
|
||||
|
||||
# opc-plc-rc — reverse-connect (server-initiated) variant. The simulator
|
||||
# acts as the OPC UA server but, unlike the regular service above, it dials
|
||||
# OUT to the client's listener URL instead of accepting an inbound dial.
|
||||
# Mirrors the OT-DMZ topology where the plant firewall only permits
|
||||
# outbound traffic from the upstream server. The driver-side test fixture
|
||||
# binds opc.tcp://0.0.0.0:4844 and waits for opc-plc-rc to ReverseHello.
|
||||
#
|
||||
# `--rc` is opc-plc's reverse-connect knob — value is the client URL the
|
||||
# simulator should dial when it has no inbound connection. host.docker.internal
|
||||
# is the docker-for-windows / docker-for-mac shorthand for the host's IP;
|
||||
# on Linux hosts use --add-host=host.docker.internal:host-gateway.
|
||||
opc-plc-rc:
|
||||
image: mcr.microsoft.com/iotedge/opc-plc:2.14.10
|
||||
container_name: otopcua-opc-plc-rc
|
||||
restart: "no"
|
||||
extra_hosts:
|
||||
- "host.docker.internal:host-gateway"
|
||||
command:
|
||||
# --pn=50001: bind on a different port so this container can run alongside
|
||||
# the dial-mode simulator above. Reverse-connect doesn't require
|
||||
# the client to know this port (the simulator is the dialer)
|
||||
# but it still has to bind one for any incoming admin queries.
|
||||
# --rc: reverse-connect target — the simulator dials this URL and
|
||||
# presents its OPC UA endpoint over the inbound socket. Must
|
||||
# point at the test runner's listener.
|
||||
# --ut/--aa/--alm: same flags as the regular profile.
|
||||
- "--pn=50001"
|
||||
- "--rc=opc.tcp://host.docker.internal:4844"
|
||||
- "--ut"
|
||||
- "--aa"
|
||||
- "--alm"
|
||||
healthcheck:
|
||||
test: ["CMD-SHELL", "netstat -an | grep -q ':50001.*LISTEN' || exit 1"]
|
||||
interval: 5s
|
||||
timeout: 2s
|
||||
retries: 10
|
||||
start_period: 10s
|
||||
|
||||
Reference in New Issue