feat(heidenhain): PLC/DATA parity with pyLSV2 — FF bits, INPUT/OUTPUT_DWORD, PLCDEBUG write-up
- PLC bit areas (MARKER/INPUT/OUTPUT/COUNTER/TIMER) accept 00/01/FF: real iTNC 530s return FF for the same operands over R_DP, and pyLSV2 decodes them as non-zero = true. 02..FE stay BadDecodingError. - New PLC:INPUT_DWORD / PLC:OUTPUT_DWORD areas (pyLSV2 MemoryType 13/12): signed int32le, element index x 4 over the input/output-word byte pools. - R_PR offsets agree with pyLSV2. Its count units (BYTE x2, WORD/IW as word counts) conflict with the captured controls, so we keep the captures and pin them in a test. - Docs: pyLSV2 correspondence table, native-operand mapping (no aliases), and why raw R_MB is refused (pyLSV2 logs in as the write-capable PLCDEBUG role). That stays an owner decision; Lsv2ReadOnlyPolicy is unchanged. Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
This commit is contained in:
@@ -353,6 +353,10 @@ panel with the NAT/IPv6-zone/loose-match caveats) / CLI `--validate-host-name`.
|
||||
`BadConfigurationError` on that role's reads only
|
||||
(`HeidenhainCredentialPersisted`). Hardware-unproven: the in-process simulator + Java golden vectors are the evidence;
|
||||
`Category=LiveIntegration` (`HEIDENHAIN_LSV2_HOST`) is the commissioning gate. `docs/drivers/Heidenhain.md`.
|
||||
Raw `R_MB` is refused on real iTNC 530s because (per pyLSV2) it needs the **PLCDEBUG** login, a write-capable role
|
||||
(pyLSV2 also uses it for `C_MC` machine-parameter writes). Enabling it is an owner decision. Do not add it to work
|
||||
around the refusal; `DATA:/PLC/memory/…` reads the same operands. PLC/DATA decoding is pyLSV2-parity, except
|
||||
pyLSV2's R_PR count units, which the real captures contradict (§"pyLSV2 correspondence").
|
||||
- **Heidenhain alarms (#831):** an `ALARM:` selector (`*`, `OTHER`, `CLASS=<r>[/GROUP=<r>][/NUMBER=<r>]`, `<r>` = `n` |
|
||||
`lo..hi`) + the `alarm` object = ONE condition at the RawPath (either alone is REFUSED by the factory, so editor/save
|
||||
path/CSV/deploy agree; data type fixed `Boolean`). Opt-in per tag, no driver flag (FOCAS #647 precedent); `Alarms/*`
|
||||
|
||||