fix(scripted-alarms): log failed event-report via SDK trace + correct sink doc (T16 review)
This commit is contained in:
@@ -20,7 +20,8 @@ public interface IOpcUaAddressSpaceSink
|
|||||||
/// this projects the whole <see cref="AlarmConditionSnapshot"/>
|
/// this projects the whole <see cref="AlarmConditionSnapshot"/>
|
||||||
/// (Enabled/Active/Acked/Confirmed/Shelving/Severity/Message) onto it and recomputes Retain;
|
/// (Enabled/Active/Acked/Confirmed/Shelving/Severity/Message) onto it and recomputes Retain;
|
||||||
/// otherwise it falls back to the legacy two-element <c>[Active, Acknowledged]</c> placeholder
|
/// otherwise it falls back to the legacy two-element <c>[Active, Acknowledged]</c> placeholder
|
||||||
/// variable. No OPC UA event is fired — that is T16's responsibility.</summary>
|
/// variable. A materialised condition also fires a Part 9 condition event on each transition (T16)
|
||||||
|
/// so subscribed clients receive the alarm event, not just the changed attributes.</summary>
|
||||||
/// <param name="alarmNodeId">The OPC UA node ID of the alarm (== ScriptedAlarmId for materialised conditions).</param>
|
/// <param name="alarmNodeId">The OPC UA node ID of the alarm (== ScriptedAlarmId for materialised conditions).</param>
|
||||||
/// <param name="state">The full condition state to project onto the node.</param>
|
/// <param name="state">The full condition state to project onto the node.</param>
|
||||||
/// <param name="sourceTimestampUtc">The source timestamp in UTC.</param>
|
/// <param name="sourceTimestampUtc">The source timestamp in UTC.</param>
|
||||||
|
|||||||
@@ -224,13 +224,21 @@ public sealed class OtOpcUaNodeManager : CustomNodeManager2
|
|||||||
snapshot.Initialize(SystemContext, alarm);
|
snapshot.Initialize(SystemContext, alarm);
|
||||||
alarm.ReportEvent(SystemContext, snapshot);
|
alarm.ReportEvent(SystemContext, snapshot);
|
||||||
}
|
}
|
||||||
catch (Exception)
|
catch (Exception ex)
|
||||||
{
|
{
|
||||||
// A failed event report must NOT break the state projection or the calling actor: the node's
|
// A failed event report must NOT break the state projection or the calling actor: the node's
|
||||||
// state has already been applied + ClearChangeMasks'd, so attribute subscribers still see the
|
// state has already been applied + ClearChangeMasks'd, so attribute subscribers still see the
|
||||||
// change; only the event delivery is lost. There is no logger on this CustomNodeManager2
|
// change; only the event delivery is lost. This CustomNodeManager2 carries no ILogger, so log
|
||||||
// (the SDK base class carries none), so swallow rather than propagate. T19's live Client.CLI
|
// through the SDK's static trace (Utils.LogError) instead of swallowing silently — a recurring
|
||||||
|
// failure here is then visible in the server log rather than invisible. T19's live Client.CLI
|
||||||
// run is the integration proof that the happy path delivers.
|
// run is the integration proof that the happy path delivers.
|
||||||
|
// Utils.LogError routes to the SDK's trace sink. It's [Obsolete] in 1.5.378 in favour of an
|
||||||
|
// ITelemetryContext/ILogger this CustomNodeManager2 doesn't have wired — suppress the
|
||||||
|
// deprecation here (wiring the telemetry logger through is a separate follow-up); the point is
|
||||||
|
// that a recurring failure is visible in the server trace rather than silently swallowed.
|
||||||
|
#pragma warning disable CS0618 // Type or member is obsolete
|
||||||
|
Utils.LogError(ex, "OtOpcUaNodeManager: failed to report Part 9 condition event for {0}", alarm.NodeId);
|
||||||
|
#pragma warning restore CS0618
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|||||||