feat(focas): CNC alarms reach Part 9 conditions via ALARM: tags (#647)

An ALARM: address (*, <Type>, <Type>/<n>, <Type>/<lo>-<hi>, T<code>, OTHER) on a raw tag that
also carries the cross-driver alarm object is ONE condition with ConditionId == RawPath and a
Kind (Raise / Retrigger / Clear), so DriverHostActor.ForwardNativeAlarm routes it and
NativeAlarmProjector activates it. Fixes all seven triage defects:

1. SubscribeAlarmsAsync treated the host's RawPaths as device hosts -> nothing polled.
2. Decorated "{host}#{Type}:{Number}" ConditionId -> every event dropped.
3. No Kind -> projector kept prior state.
4. WireFocasClient.ReadAlarmsAsync answered [] on failure -> mass clear + un-acked re-raise.
   It now throws; a failed device read keeps every condition's state.
5. Acks lost on reconnect -> told-record dedup (MTConnect #626 pattern) held for the driver's
   lifetime; same-set re-subscribe / re-init re-raise nothing; changed set prunes leavers only.
6. Subscribe threw while AlarmProjection.Enabled=false -> the tag is the opt-in; flag is a no-op.
7. Alarm tags could not be authored -> ALARM: grammar (FocasAlarmSelector, Contracts) backs the
   editor, the address picker, the deploy-time inspector and driver init.

Severity: authored alarm.severity -> exact OpcUaSeverity; else the 16i-era type bucket. The type
table stays the only one (moved to Contracts, documented 16i-era; 30i codes not invented; raw
T<code> selector + raw code in every message). Read-only: ack is server-side. Also clears the
value table on a re-initialise (#630 gap that let a removed/moved tag keep reading).

E2E: Runtime.Tests FocasNativeAlarmEndToEndTests drives the real driver through the real
DriverHostActor and asserts the condition goes Active then inactive.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
This commit is contained in:
Joseph Doherty
2026-10-08 19:46:48 -04:00
parent 8801631739
commit 482bafdfac
27 changed files with 2110 additions and 515 deletions
@@ -115,19 +115,18 @@ public sealed class WireFocasClient : IFocasClient
}
/// <inheritdoc />
/// <remarks>
/// Gitea #647: every failure THROWS — a disconnected session, a non-OK return code and a wire fault
/// alike. This used to answer <c>[]</c> for all three, which the alarm projection could not tell
/// from "no alarms active": every comms blip cleared every active alarm, and recovery re-raised them
/// un-acknowledged. <see cref="FocasWireException"/> propagates as-is.
/// </remarks>
public async Task<IReadOnlyList<FocasActiveAlarm>> ReadAlarmsAsync(CancellationToken cancellationToken)
{
if (!_wire.IsConnected) return [];
try
{
var result = await _wire.ReadAlarmsAsync(FocasAlarmType.All, 32, cancellationToken).ConfigureAwait(false);
if (!result.IsOk || result.Value is null) return [];
return result.Value.Select(Map).ToList();
}
catch (FocasWireException)
{
return [];
}
RequireConnected();
var result = await _wire.ReadAlarmsAsync(FocasAlarmType.All, MaxAlarmsPerRead, cancellationToken).ConfigureAwait(false);
ThrowIfRcNonZero(result.Rc, "cnc_rdalmmsg2", result.IsOk);
return (result.Value ?? []).Select(Map).ToList();
static FocasActiveAlarm Map(WireAlarm a) => new(
AlarmNumber: a.AlarmNumber,
@@ -468,6 +467,12 @@ public sealed class WireFocasClient : IFocasClient
return true;
}
/// <summary>
/// Records requested per <c>cnc_rdalmmsg2</c> call. A reply carrying exactly this many may have been
/// truncated by the CNC; the alarm projection warns about it (Gitea #647).
/// </summary>
internal const short MaxAlarmsPerRead = 32;
private void RequireConnected()
{
if (!_wire.IsConnected)