feat(abcip): Transport option selects native or libplctag across driver, probe and CLI
This commit is contained in:
@@ -26,6 +26,11 @@ public abstract class AbCipCommandBase : DriverCommandBase
|
||||
"ControlLogix / CompactLogix / Micro800 / GuardLogix (default ControlLogix).")]
|
||||
public AbCipPlcFamily Family { get; init; } = AbCipPlcFamily.ControlLogix;
|
||||
|
||||
/// <summary>Gets the transport stack used to reach the PLC.</summary>
|
||||
[CommandOption("transport", Description =
|
||||
"Transport stack: libplctag (default) or native (managed EtherNet/IP + CIP).")]
|
||||
public AbCipTransport Transport { get; init; } = AbCipTransport.Libplctag;
|
||||
|
||||
/// <summary>Gets the per-operation timeout in milliseconds.</summary>
|
||||
[CommandOption("timeout-ms", Description = "Per-operation timeout in ms (default 5000).")]
|
||||
public int TimeoutMs { get; init; } = 5000;
|
||||
@@ -68,6 +73,7 @@ public abstract class AbCipCommandBase : DriverCommandBase
|
||||
WriteIdempotent: t.WriteIdempotent,
|
||||
DeviceName: t.DeviceHostAddress))],
|
||||
Timeout = Timeout,
|
||||
Transport = Transport,
|
||||
Probe = new AbCipProbeOptions { Enabled = false },
|
||||
EnableControllerBrowse = false,
|
||||
EnableAlarmProjection = false,
|
||||
|
||||
@@ -6,6 +6,6 @@ return await new CliApplicationBuilder()
|
||||
.SetDescription(
|
||||
"OtOpcUa AB CIP test-client — ad-hoc probe + Logix symbolic reads/writes + polled " +
|
||||
"subscriptions against ControlLogix / CompactLogix / Micro800 / GuardLogix families " +
|
||||
"via libplctag. Second of six driver CLIs; mirrors otopcua-modbus-cli's shape.")
|
||||
"via libplctag or the native transport. Second of six driver CLIs; mirrors otopcua-modbus-cli's shape.")
|
||||
.Build()
|
||||
.RunAsync(args);
|
||||
|
||||
Reference in New Issue