Apply code style formatting and restore partial modifiers on Avalonia views

Linter/formatter pass across the full codebase. Restores required partial
keyword on AXAML code-behind classes that the formatter incorrectly removed.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
This commit is contained in:
Joseph Doherty
2026-03-31 07:58:13 -04:00
parent 55ef854612
commit 41a6b66943
221 changed files with 4274 additions and 3823 deletions

View File

@@ -1,4 +1,5 @@
using System;
using Opc.Ua;
using Shouldly;
using Xunit;
using ZB.MOM.WW.LmxOpcUa.Host.Domain;
@@ -7,12 +8,12 @@ using ZB.MOM.WW.LmxOpcUa.Host.OpcUa;
namespace ZB.MOM.WW.LmxOpcUa.Tests.OpcUa
{
/// <summary>
/// Verifies how bridge VTQ values are translated to and from OPC UA data values for the published namespace.
/// Verifies how bridge VTQ values are translated to and from OPC UA data values for the published namespace.
/// </summary>
public class DataValueConverterTests
{
/// <summary>
/// Confirms that boolean runtime values are preserved when converted to OPC UA data values.
/// Confirms that boolean runtime values are preserved when converted to OPC UA data values.
/// </summary>
[Fact]
public void FromVtq_Boolean()
@@ -20,11 +21,11 @@ namespace ZB.MOM.WW.LmxOpcUa.Tests.OpcUa
var vtq = Vtq.Good(true);
var dv = DataValueConverter.FromVtq(vtq);
dv.Value.ShouldBe(true);
Opc.Ua.StatusCode.IsGood(dv.StatusCode).ShouldBe(true);
StatusCode.IsGood(dv.StatusCode).ShouldBe(true);
}
/// <summary>
/// Confirms that integer runtime values are preserved when converted to OPC UA data values.
/// Confirms that integer runtime values are preserved when converted to OPC UA data values.
/// </summary>
[Fact]
public void FromVtq_Int32()
@@ -35,7 +36,7 @@ namespace ZB.MOM.WW.LmxOpcUa.Tests.OpcUa
}
/// <summary>
/// Confirms that float runtime values are preserved when converted to OPC UA data values.
/// Confirms that float runtime values are preserved when converted to OPC UA data values.
/// </summary>
[Fact]
public void FromVtq_Float()
@@ -46,7 +47,7 @@ namespace ZB.MOM.WW.LmxOpcUa.Tests.OpcUa
}
/// <summary>
/// Confirms that double runtime values are preserved when converted to OPC UA data values.
/// Confirms that double runtime values are preserved when converted to OPC UA data values.
/// </summary>
[Fact]
public void FromVtq_Double()
@@ -57,7 +58,7 @@ namespace ZB.MOM.WW.LmxOpcUa.Tests.OpcUa
}
/// <summary>
/// Confirms that string runtime values are preserved when converted to OPC UA data values.
/// Confirms that string runtime values are preserved when converted to OPC UA data values.
/// </summary>
[Fact]
public void FromVtq_String()
@@ -68,7 +69,7 @@ namespace ZB.MOM.WW.LmxOpcUa.Tests.OpcUa
}
/// <summary>
/// Confirms that UTC timestamps remain UTC when a VTQ is converted for OPC UA clients.
/// Confirms that UTC timestamps remain UTC when a VTQ is converted for OPC UA clients.
/// </summary>
[Fact]
public void FromVtq_DateTime_IsUtc()
@@ -80,7 +81,7 @@ namespace ZB.MOM.WW.LmxOpcUa.Tests.OpcUa
}
/// <summary>
/// Confirms that elapsed-time values are exposed to OPC UA clients in seconds.
/// Confirms that elapsed-time values are exposed to OPC UA clients in seconds.
/// </summary>
[Fact]
public void FromVtq_TimeSpan_ConvertedToSeconds()
@@ -91,7 +92,7 @@ namespace ZB.MOM.WW.LmxOpcUa.Tests.OpcUa
}
/// <summary>
/// Confirms that string arrays remain arrays when exposed through OPC UA.
/// Confirms that string arrays remain arrays when exposed through OPC UA.
/// </summary>
[Fact]
public void FromVtq_StringArray()
@@ -103,7 +104,7 @@ namespace ZB.MOM.WW.LmxOpcUa.Tests.OpcUa
}
/// <summary>
/// Confirms that integer arrays remain arrays when exposed through OPC UA.
/// Confirms that integer arrays remain arrays when exposed through OPC UA.
/// </summary>
[Fact]
public void FromVtq_IntArray()
@@ -115,29 +116,29 @@ namespace ZB.MOM.WW.LmxOpcUa.Tests.OpcUa
}
/// <summary>
/// Confirms that bad runtime quality is translated to a bad OPC UA status code.
/// Confirms that bad runtime quality is translated to a bad OPC UA status code.
/// </summary>
[Fact]
public void FromVtq_BadQuality_MapsToStatusCode()
{
var vtq = Vtq.Bad(Quality.BadCommFailure);
var dv = DataValueConverter.FromVtq(vtq);
Opc.Ua.StatusCode.IsBad(dv.StatusCode).ShouldBe(true);
StatusCode.IsBad(dv.StatusCode).ShouldBe(true);
}
/// <summary>
/// Confirms that uncertain runtime quality is translated to an uncertain OPC UA status code.
/// Confirms that uncertain runtime quality is translated to an uncertain OPC UA status code.
/// </summary>
[Fact]
public void FromVtq_UncertainQuality()
{
var vtq = Vtq.Uncertain(42);
var dv = DataValueConverter.FromVtq(vtq);
Opc.Ua.StatusCode.IsUncertain(dv.StatusCode).ShouldBe(true);
StatusCode.IsUncertain(dv.StatusCode).ShouldBe(true);
}
/// <summary>
/// Confirms that null runtime values remain null when converted for OPC UA.
/// Confirms that null runtime values remain null when converted for OPC UA.
/// </summary>
[Fact]
public void FromVtq_NullValue()
@@ -148,7 +149,7 @@ namespace ZB.MOM.WW.LmxOpcUa.Tests.OpcUa
}
/// <summary>
/// Confirms that a data value can round-trip back into a VTQ without losing the process value or quality.
/// Confirms that a data value can round-trip back into a VTQ without losing the process value or quality.
/// </summary>
[Fact]
public void ToVtq_RoundTrip()
@@ -161,4 +162,4 @@ namespace ZB.MOM.WW.LmxOpcUa.Tests.OpcUa
roundTrip.Quality.ShouldBe(Quality.Good);
}
}
}
}