Apply code style formatting and restore partial modifiers on Avalonia views

Linter/formatter pass across the full codebase. Restores required partial
keyword on AXAML code-behind classes that the formatter incorrectly removed.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
This commit is contained in:
Joseph Doherty
2026-03-31 07:58:13 -04:00
parent 55ef854612
commit 41a6b66943
221 changed files with 4274 additions and 3823 deletions

View File

@@ -16,23 +16,54 @@ namespace ZB.MOM.WW.LmxOpcUa.Tests.Integration
{
Hierarchy = new List<GalaxyObjectInfo>
{
new GalaxyObjectInfo { GobjectId = 1, TagName = "TestObj", BrowseName = "TestObj", ParentGobjectId = 0, IsArea = false }
new()
{
GobjectId = 1, TagName = "TestObj", BrowseName = "TestObj", ParentGobjectId = 0, IsArea = false
}
},
Attributes = new List<GalaxyAttributeInfo>
{
new GalaxyAttributeInfo { GobjectId = 1, TagName = "TestObj", AttributeName = "FreeAttr", FullTagReference = "TestObj.FreeAttr", MxDataType = 5, SecurityClassification = 0 },
new GalaxyAttributeInfo { GobjectId = 1, TagName = "TestObj", AttributeName = "OperateAttr", FullTagReference = "TestObj.OperateAttr", MxDataType = 5, SecurityClassification = 1 },
new GalaxyAttributeInfo { GobjectId = 1, TagName = "TestObj", AttributeName = "SecuredAttr", FullTagReference = "TestObj.SecuredAttr", MxDataType = 5, SecurityClassification = 2 },
new GalaxyAttributeInfo { GobjectId = 1, TagName = "TestObj", AttributeName = "VerifiedAttr", FullTagReference = "TestObj.VerifiedAttr", MxDataType = 5, SecurityClassification = 3 },
new GalaxyAttributeInfo { GobjectId = 1, TagName = "TestObj", AttributeName = "TuneAttr", FullTagReference = "TestObj.TuneAttr", MxDataType = 5, SecurityClassification = 4 },
new GalaxyAttributeInfo { GobjectId = 1, TagName = "TestObj", AttributeName = "ConfigAttr", FullTagReference = "TestObj.ConfigAttr", MxDataType = 5, SecurityClassification = 5 },
new GalaxyAttributeInfo { GobjectId = 1, TagName = "TestObj", AttributeName = "ViewOnlyAttr", FullTagReference = "TestObj.ViewOnlyAttr", MxDataType = 5, SecurityClassification = 6 },
new()
{
GobjectId = 1, TagName = "TestObj", AttributeName = "FreeAttr",
FullTagReference = "TestObj.FreeAttr", MxDataType = 5, SecurityClassification = 0
},
new()
{
GobjectId = 1, TagName = "TestObj", AttributeName = "OperateAttr",
FullTagReference = "TestObj.OperateAttr", MxDataType = 5, SecurityClassification = 1
},
new()
{
GobjectId = 1, TagName = "TestObj", AttributeName = "SecuredAttr",
FullTagReference = "TestObj.SecuredAttr", MxDataType = 5, SecurityClassification = 2
},
new()
{
GobjectId = 1, TagName = "TestObj", AttributeName = "VerifiedAttr",
FullTagReference = "TestObj.VerifiedAttr", MxDataType = 5, SecurityClassification = 3
},
new()
{
GobjectId = 1, TagName = "TestObj", AttributeName = "TuneAttr",
FullTagReference = "TestObj.TuneAttr", MxDataType = 5, SecurityClassification = 4
},
new()
{
GobjectId = 1, TagName = "TestObj", AttributeName = "ConfigAttr",
FullTagReference = "TestObj.ConfigAttr", MxDataType = 5, SecurityClassification = 5
},
new()
{
GobjectId = 1, TagName = "TestObj", AttributeName = "ViewOnlyAttr",
FullTagReference = "TestObj.ViewOnlyAttr", MxDataType = 5, SecurityClassification = 6
}
}
};
}
/// <summary>
/// Verifies that writable Galaxy security classifications publish OPC UA variables with read-write access.
/// Verifies that writable Galaxy security classifications publish OPC UA variables with read-write access.
/// </summary>
[Fact]
public async Task ReadWriteAttribute_HasCurrentReadOrWrite_AccessLevel()
@@ -52,11 +83,14 @@ namespace ZB.MOM.WW.LmxOpcUa.Tests.Integration
$"{attrName} should be ReadWrite");
}
}
finally { await fixture.DisposeAsync(); }
finally
{
await fixture.DisposeAsync();
}
}
/// <summary>
/// Verifies that secured and view-only Galaxy classifications publish OPC UA variables with read-only access.
/// Verifies that secured and view-only Galaxy classifications publish OPC UA variables with read-only access.
/// </summary>
[Fact]
public async Task ReadOnlyAttribute_HasCurrentRead_AccessLevel()
@@ -76,11 +110,14 @@ namespace ZB.MOM.WW.LmxOpcUa.Tests.Integration
$"{attrName} should be ReadOnly");
}
}
finally { await fixture.DisposeAsync(); }
finally
{
await fixture.DisposeAsync();
}
}
/// <summary>
/// Verifies that the bridge rejects writes against Galaxy attributes whose security classification is read-only.
/// Verifies that the bridge rejects writes against Galaxy attributes whose security classification is read-only.
/// </summary>
[Fact]
public async Task Write_ToReadOnlyAttribute_IsRejected()
@@ -96,17 +133,20 @@ namespace ZB.MOM.WW.LmxOpcUa.Tests.Integration
var result = client.Write(nodeId, "test");
StatusCode.IsBad(result).ShouldBeTrue("Write to ReadOnly attribute should be rejected");
}
finally { await fixture.DisposeAsync(); }
finally
{
await fixture.DisposeAsync();
}
}
/// <summary>
/// Verifies that writes succeed for Galaxy attributes whose security classification permits operator updates.
/// Verifies that writes succeed for Galaxy attributes whose security classification permits operator updates.
/// </summary>
[Fact]
public async Task Write_ToReadWriteAttribute_Succeeds()
{
var mxClient = new FakeMxAccessClient();
var fixture = OpcUaServerFixture.WithFakeMxAccessClient(mxClient: mxClient, repo: CreateRepoWithSecurityLevels());
var fixture = OpcUaServerFixture.WithFakeMxAccessClient(mxClient, CreateRepoWithSecurityLevels());
await fixture.InitializeAsync();
try
{
@@ -117,7 +157,10 @@ namespace ZB.MOM.WW.LmxOpcUa.Tests.Integration
var result = client.Write(nodeId, "test");
StatusCode.IsGood(result).ShouldBeTrue("Write to ReadWrite attribute should succeed");
}
finally { await fixture.DisposeAsync(); }
finally
{
await fixture.DisposeAsync();
}
}
}
}
}