fix(v3-batch4-wp4): alarm fan-out hardening — event-delivery test, resolution-failure meter, teardown guards (Wave C review M1/M2/M3/L1/L3)
M1 — over-the-wire event-delivery proof (new NativeAlarmMultiNotifierEventDeliveryTests in OpcUaServer.IntegrationTests): boots the real server, wires one condition to two equipment folders, fires ONE transition, and asserts a Server-object subscriber gets EXACTLY ONE event (the shared-InstanceStateSnapshot queue dedup), plus overlapping Server + equipment-folder subscribers each get exactly one copy. Captures via the subscription FastEventCallback keyed by ClientHandle (the per-item Notification/DequeueEvents path delivers nothing for these conditions in the SDK client — the working capture is the fast callback). M2 — resolution-failure signal + path-agreement tripwire (AddressSpaceApplier): when a native alarm HAS ReferencingEquipmentPaths but NONE resolve to an equipment folder, count it as a failed node (degraded-apply meter) + LogWarning instead of a silent skip; documented the DisplayName==Name coupling as a binding invariant. Tests: Composer_referencing_equipment_paths_resolve_back_to_equipment_ids_in_the_applier (real composer output → applier inversion) + ..._unresolvable_referencing_equipment_counts_as_failed. M3 — WireAlarmNotifiers is now a RECONCILE (unwires a folder dropped from the supplied set, bidirectionally) so a future surgical ChangedRawTags path can't leave a de-referenced equipment receiving the alarm; binding guard comment added on the classifier's ChangedRawTags→Rebuild branch. Test: WireAlarmNotifiers_reconciles_a_dropped_folder_out_of_the_notifier_set. L1 — MaterialiseAlarmCondition's kind-swap drop-and-recreate now calls UnwireAlarmNotifiers(conditionKey) before discarding the old instance (teardown symmetry). L3 — BuildEquipmentIdByFolderPath LogWarnings on a duplicate Area/Line/Name collision (defense-in-depth; UNS uniqueness prevents it). Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
This commit is contained in:
@@ -716,8 +716,21 @@ public sealed class AddressSpaceApplier
|
||||
.Select(id => id!)
|
||||
.Distinct(StringComparer.Ordinal)
|
||||
.ToList();
|
||||
if (equipFolderNodeIds.Count > 0 &&
|
||||
!SafeWireAlarmNotifiers(t.NodeId, AddressSpaceRealm.Raw, equipFolderNodeIds, AddressSpaceRealm.Uns))
|
||||
if (equipFolderNodeIds.Count == 0)
|
||||
{
|
||||
// Wave C review M2: the alarm HAS referencing equipment but NONE of its paths resolved
|
||||
// to an EquipmentId folder — the native fan-out to those equipment is silently absent.
|
||||
// Surface it (Warning + a failed-node tally so the degraded-apply meter fires) instead
|
||||
// of swallowing zero operator signal. Today this only happens on a broken UNS ancestry /
|
||||
// an invalid segment (the composer would have dropped the equipment too); the latent
|
||||
// risk is a future editable Area/Line display-name feature breaking the path↔id coupling
|
||||
// (see BuildEquipmentIdByFolderPath + AddressSpaceComposerPathParityTests).
|
||||
_logger.LogWarning(
|
||||
"AddressSpaceApplier: native alarm {Node} has {Count} referencing equipment path(s) but NONE resolved to an equipment folder — the alarm's multi-notifier fan-out to those equipment is absent (paths={Paths})",
|
||||
t.NodeId, t.ReferencingEquipmentPaths.Count, string.Join(", ", t.ReferencingEquipmentPaths));
|
||||
failed++;
|
||||
}
|
||||
else if (!SafeWireAlarmNotifiers(t.NodeId, AddressSpaceRealm.Raw, equipFolderNodeIds, AddressSpaceRealm.Uns))
|
||||
{
|
||||
failed++;
|
||||
}
|
||||
@@ -1082,13 +1095,17 @@ public sealed class AddressSpaceApplier
|
||||
/// as name paths (<c>V3NodeIds.Uns(areaName, lineName, equipName)</c>), but the equipment folders were
|
||||
/// materialised under their logical <c>EquipmentId</c> by <see cref="MaterialiseHierarchy"/>, so the
|
||||
/// multi-notifier wiring must translate path → id. This inverts the composer's own equipment-folder-path
|
||||
/// construction EXACTLY (area/line/equipment DisplayName == the UNS level Name, so the paths match
|
||||
/// byte-for-byte); an invalid segment throws in <see cref="V3NodeIds.Uns"/> and is skipped (the same
|
||||
/// drop the composer applies), so an entry the composer produced always resolves here.
|
||||
/// construction EXACTLY — <b>path↔id coupling invariant:</b> the composer builds the path from the
|
||||
/// Area/Line/Equipment <c>Name</c>; this inverts it via the projected <c>DisplayName</c>, which the
|
||||
/// composer sets to that same <c>Name</c> at every level (verified by
|
||||
/// <c>AddressSpaceComposerPathParityTests</c>). A future editable Area/Line display-name feature that
|
||||
/// lets <c>DisplayName != Name</c> would silently break this inversion — that test is the tripwire.
|
||||
/// An invalid segment throws in <see cref="V3NodeIds.Uns"/> and is skipped (the same drop the composer
|
||||
/// applies), so an entry the composer produced always resolves here.
|
||||
/// </summary>
|
||||
/// <param name="composition">The composition carrying the UNS topology + equipment nodes.</param>
|
||||
/// <returns>A map from each resolvable equipment folder path to its EquipmentId.</returns>
|
||||
private static IReadOnlyDictionary<string, string> BuildEquipmentIdByFolderPath(AddressSpaceComposition composition)
|
||||
private IReadOnlyDictionary<string, string> BuildEquipmentIdByFolderPath(AddressSpaceComposition composition)
|
||||
{
|
||||
var areaName = composition.UnsAreas
|
||||
.GroupBy(a => a.UnsAreaId, StringComparer.Ordinal)
|
||||
@@ -1103,8 +1120,20 @@ public sealed class AddressSpaceApplier
|
||||
if (string.IsNullOrWhiteSpace(e.UnsLineId)) continue;
|
||||
if (!lineByid.TryGetValue(e.UnsLineId, out var line)) continue;
|
||||
if (!areaName.TryGetValue(line.UnsAreaId, out var aName)) continue;
|
||||
try { map[V3NodeIds.Uns(aName, line.DisplayName, e.DisplayName)] = e.EquipmentId; }
|
||||
catch (ArgumentException) { /* invalid segment — dropped, mirroring the composer */ }
|
||||
string path;
|
||||
try { path = V3NodeIds.Uns(aName, line.DisplayName, e.DisplayName); }
|
||||
catch (ArgumentException) { continue; /* invalid segment — dropped, mirroring the composer */ }
|
||||
// Wave C review L3: two equipment sharing an identical Area/Line/Name collapse to one id
|
||||
// (last-write-wins). UNS uniqueness prevents this, so it is defense-in-depth: warn (mirroring the
|
||||
// composer's own last-write-wins spot) rather than silently pick one — a collision here would send
|
||||
// the alarm's notifier to the wrong equipment folder.
|
||||
if (map.TryGetValue(path, out var existing) && !string.Equals(existing, e.EquipmentId, StringComparison.Ordinal))
|
||||
{
|
||||
_logger.LogWarning(
|
||||
"AddressSpaceApplier: two equipment share the UNS folder path {Path} ({Existing} vs {New}) — the native-alarm notifier map collapses them (last-write-wins); UNS uniqueness should prevent this",
|
||||
path, existing, e.EquipmentId);
|
||||
}
|
||||
map[path] = e.EquipmentId;
|
||||
}
|
||||
return map;
|
||||
}
|
||||
|
||||