Phase 0 — mechanical rename ZB.MOM.WW.LmxOpcUa.* → ZB.MOM.WW.OtOpcUa.*

Renames all 11 projects (5 src + 6 tests), the .slnx solution file, all source-file namespaces, all axaml namespace references, and all v1 documentation references in CLAUDE.md and docs/*.md (excluding docs/v2/ which is already in OtOpcUa form). Also updates the TopShelf service registration name from "LmxOpcUa" to "OtOpcUa" per Phase 0 Task 0.6.

Preserves runtime identifiers per Phase 0 Out-of-Scope rules to avoid breaking v1/v2 client trust during coexistence: OPC UA `ApplicationUri` defaults (`urn:{GalaxyName}:LmxOpcUa`), server `EndpointPath` (`/LmxOpcUa`), `ServerName` default (feeds cert subject CN), `MxAccessConfiguration.ClientName` default (defensive — stays "LmxOpcUa" for MxAccess audit-trail consistency), client OPC UA identifiers (`ApplicationName = "LmxOpcUaClient"`, `ApplicationUri = "urn:localhost:LmxOpcUaClient"`, cert directory `%LocalAppData%\LmxOpcUaClient\pki\`), and the `LmxOpcUaServer` class name (class rename out of Phase 0 scope per Task 0.5 sed pattern; happens in Phase 1 alongside `LmxNodeManager → GenericDriverNodeManager` Core extraction). 23 LmxOpcUa references retained, all enumerated and justified in `docs/v2/implementation/exit-gate-phase-0.md`.

Build clean: 0 errors, 30 warnings (lower than baseline 167). Tests at strict improvement over baseline: 821 passing / 1 failing vs baseline 820 / 2 (one flaky pre-existing failure passed this run; the other still fails — both pre-existing and unrelated to the rename). `Client.UI.Tests`, `Historian.Aveva.Tests`, `Client.Shared.Tests`, `IntegrationTests` all match baseline exactly. Exit gate compliance results recorded in `docs/v2/implementation/exit-gate-phase-0.md` with all 7 checks PASS or DEFERRED-to-PR-review (#7 service install verification needs Windows service permissions on the reviewer's box).

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
Joseph Doherty
2026-04-17 13:57:47 -04:00
parent 5b8d708c58
commit 3b2defd94f
293 changed files with 841 additions and 722 deletions

View File

@@ -0,0 +1,98 @@
using Opc.Ua;
using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Client.CLI.Commands;
using ZB.MOM.WW.OtOpcUa.Client.CLI.Tests.Fakes;
namespace ZB.MOM.WW.OtOpcUa.Client.CLI.Tests;
public class ReadCommandTests
{
[Fact]
public async Task Execute_PrintsReadValue()
{
var sourceTime = new DateTime(2025, 6, 15, 10, 30, 0, DateTimeKind.Utc);
var serverTime = new DateTime(2025, 6, 15, 10, 30, 1, DateTimeKind.Utc);
var fakeService = new FakeOpcUaClientService
{
ReadValueResult = new DataValue(
new Variant("Hello"),
StatusCodes.Good,
sourceTime,
serverTime)
};
var factory = new FakeOpcUaClientServiceFactory(fakeService);
var command = new ReadCommand(factory)
{
Url = "opc.tcp://localhost:4840",
NodeId = "ns=2;s=TestNode"
};
using var console = TestConsoleHelper.CreateConsole();
await command.ExecuteAsync(console);
var output = TestConsoleHelper.GetOutput(console);
output.ShouldContain("Node: ns=2;s=TestNode");
output.ShouldContain("Value: Hello");
output.ShouldContain("Status:");
output.ShouldContain("Source Time:");
output.ShouldContain("Server Time:");
}
[Fact]
public async Task Execute_CallsReadValueWithCorrectNodeId()
{
var fakeService = new FakeOpcUaClientService();
var factory = new FakeOpcUaClientServiceFactory(fakeService);
var command = new ReadCommand(factory)
{
Url = "opc.tcp://localhost:4840",
NodeId = "ns=2;s=MyVariable"
};
using var console = TestConsoleHelper.CreateConsole();
await command.ExecuteAsync(console);
fakeService.ReadNodeIds.Count.ShouldBe(1);
fakeService.ReadNodeIds[0].Identifier.ShouldBe("MyVariable");
}
[Fact]
public async Task Execute_DisconnectsInFinally()
{
var fakeService = new FakeOpcUaClientService();
var factory = new FakeOpcUaClientServiceFactory(fakeService);
var command = new ReadCommand(factory)
{
Url = "opc.tcp://localhost:4840",
NodeId = "ns=2;s=TestNode"
};
using var console = TestConsoleHelper.CreateConsole();
await command.ExecuteAsync(console);
fakeService.DisconnectCalled.ShouldBeTrue();
fakeService.DisposeCalled.ShouldBeTrue();
}
[Fact]
public async Task Execute_DisconnectsEvenOnReadError()
{
var fakeService = new FakeOpcUaClientService
{
ReadException = new InvalidOperationException("Read failed")
};
var factory = new FakeOpcUaClientServiceFactory(fakeService);
var command = new ReadCommand(factory)
{
Url = "opc.tcp://localhost:4840",
NodeId = "ns=2;s=TestNode"
};
using var console = TestConsoleHelper.CreateConsole();
await Should.ThrowAsync<InvalidOperationException>(async () => await command.ExecuteAsync(console));
fakeService.DisconnectCalled.ShouldBeTrue();
fakeService.DisposeCalled.ShouldBeTrue();
}
}