ab_server integration fixture — per-family profiles + documented CI-fetch contract. Closes task #180 (AB CIP follow-up — ab_server CI fixture). Replaces the prior hardcoded single-family fixture with a parametric AbServerProfile abstraction covering ControlLogix / CompactLogix / Micro800 / GuardLogix. Prebuilt-Windows-binary fetch is documented as a CI YAML step rather than fabricated C#-side, because SHA-pinned binary distribution is a CI workflow concern (libplctag owns releases, we pin a version + verify hash) not a test-framework concern. New AbServerProfile record + KnownProfiles static class at tests/.../AbServerProfile.cs. Four profiles: ControlLogix (widest coverage — DINT/REAL/BOOL/SINT/STRING atomic + DINT[16] array so the driver's @tags Symbol-Object decoder + array-bound path both get end-to-end coverage), CompactLogix (atomic subset — driver-side ConnectionSize quirk from PR 10 still applies since ab_server doesn't enforce the narrower limit), Micro800 (ab_server has no dedicated --plc micro800 mode — falls back to controllogix while driver-side path enforces empty routing + unconnected-only per PR 11; real Micro800 coverage requires a 2080 lab rig), GuardLogix (ab_server has no safety subsystem — profile emulates the _S-suffixed naming contract the driver's safety-ViewOnly classification reads in PR 12; real safety-lock behavior requires a 1756-L8xS physical rig). Each profile composes --plc + --tag args via BuildCliArgs(port) — pure string formatter so the composition logic is unit-testable without launching the simulator. AbServerFixture gains a ctor overload taking AbServerProfile + port (defaults back to ControlLogix on parameterless ctor so existing test suites keep compiling). Fixture's InitializeAsync hands the profile's CLI args to ProcessStartInfo.Arguments. New AbServerTheoryAttribute mirrors AbServerFactAttribute but extends TheoryAttribute so a single test can MemberData over KnownProfiles.All + cover all four families. AbCipReadSmokeTests converted from single-fact to theory parametrized over KnownProfiles.All — one row per family reads TestDINT + asserts Good status + Healthy driver state. Fixture lifecycle is explicit try/finally rather than await using because IAsyncLifetime.DisposeAsync returns ValueTask + xUnit's concrete IAsyncDisposable shim depends on xunit version; explicit beats implicit here. Eight new unit tests in AbServerProfileTests.cs (runs without the simulator so CI green even when the binary is absent): BuildCliArgs composes port + plc + tag flags in the documented order; empty seed-tag list still emits port + plc; SeedTag.ToCliSpec handles both 2-segment scalar + 3-segment array; KnownProfiles.ForFamily returns expected --plc arg for every family (verifies Micro800 + GuardLogix both fall back to controllogix); KnownProfiles.All covers every AbCipPlcFamily enum value (regression guard — adding a new family without a profile fails this test); ControlLogix seeds every atomic type the driver supports; GuardLogix seeds at least one _S-suffixed safety tag. Integration tests still skip cleanly when ab_server isn't on PATH. 11/11 unit tests passing in this project (8 new + 3 prior). Full Admin solution builds 0 errors. docs/v2/test-data-sources.md gets a new "CI fixture" subsection under §2.Gotchas with the exact GitHub Actions YAML step — fetch the pinned libplctag release, SHA256-verify against a pinned hash recorded in the repo's CI lockfile (drift = fail closed), extract, append to PATH. The C# harness stays PATH-driven so dev-box installs (cmake + make from source) work identically to CI.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -6,28 +6,44 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.AbCip.IntegrationTests;
|
||||
|
||||
/// <summary>
|
||||
/// Shared fixture that starts libplctag's <c>ab_server</c> simulator in the background for
|
||||
/// the duration of an integration test collection. Binary is expected on PATH; the per-test
|
||||
/// JSON profile is passed via <c>--config</c>.
|
||||
/// the duration of an integration test collection. The fixture takes an
|
||||
/// <see cref="AbServerProfile"/> (see <see cref="KnownProfiles"/>) so each AB family — ControlLogix,
|
||||
/// CompactLogix, Micro800, GuardLogix — starts the simulator with the right <c>--plc</c>
|
||||
/// mode + preseed tag set. Binary is expected on PATH; CI resolves that via a job step
|
||||
/// that downloads the pinned Windows build from libplctag GitHub Releases before
|
||||
/// <c>dotnet test</c> — see <c>docs/v2/test-data-sources.md §2.CI</c> for the exact step.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <para><c>ab_server</c> is a C binary shipped in the same repo as libplctag (see
|
||||
/// <c>test-data-sources.md</c> §2 and plan decision #99). On a developer workstation it's
|
||||
/// built once from source and placed on PATH; in CI we intend to publish a prebuilt Windows
|
||||
/// x64 binary as a GitHub release asset in a follow-up PR so the fixture can download +
|
||||
/// extract it at setup time. Until then every test in this project is skipped when
|
||||
/// <c>ab_server</c> is not locatable.</para>
|
||||
/// <para><c>ab_server</c> is a C binary shipped in libplctag's repo (MIT). On developer
|
||||
/// workstations it's built once from source and placed on PATH; on CI the workflow file
|
||||
/// fetches a version-pinned prebuilt + stages it. Tests skip (via
|
||||
/// <see cref="AbServerFactAttribute"/>) when the binary is not on PATH so a fresh clone
|
||||
/// without the simulator still gets a green unit-test run.</para>
|
||||
///
|
||||
/// <para>Per-family JSON profiles (ControlLogix / CompactLogix / Micro800 / GuardLogix)
|
||||
/// ship under <c>Profiles/</c> and drive the simulator's tag shape — this is where the
|
||||
/// UDT + Program-scope coverage gap will be filled by the hand-rolled stub in PR 6.</para>
|
||||
/// <para>Per-family profiles live in <see cref="KnownProfiles"/>. When a test wants a
|
||||
/// specific family, instantiate the fixture with that profile — either via a
|
||||
/// <see cref="IClassFixture{TFixture}"/> derived type or by constructing directly in a
|
||||
/// parametric test (the latter is used below for the smoke suite).</para>
|
||||
/// </remarks>
|
||||
public sealed class AbServerFixture : IAsyncLifetime
|
||||
{
|
||||
private Process? _proc;
|
||||
public int Port { get; } = 44818;
|
||||
|
||||
/// <summary>The profile the simulator was started with. Same instance the driver-side options should use.</summary>
|
||||
public AbServerProfile Profile { get; }
|
||||
public int Port { get; }
|
||||
public bool IsAvailable { get; private set; }
|
||||
|
||||
public AbServerFixture() : this(KnownProfiles.ControlLogix, AbServerProfile.DefaultPort) { }
|
||||
|
||||
public AbServerFixture(AbServerProfile profile) : this(profile, AbServerProfile.DefaultPort) { }
|
||||
|
||||
public AbServerFixture(AbServerProfile profile, int port)
|
||||
{
|
||||
Profile = profile ?? throw new ArgumentNullException(nameof(profile));
|
||||
Port = port;
|
||||
}
|
||||
|
||||
public ValueTask InitializeAsync() => InitializeAsync(default);
|
||||
public ValueTask DisposeAsync() => DisposeAsync(default);
|
||||
|
||||
@@ -45,7 +61,7 @@ public sealed class AbServerFixture : IAsyncLifetime
|
||||
StartInfo = new ProcessStartInfo
|
||||
{
|
||||
FileName = binary,
|
||||
Arguments = $"--port {Port} --plc controllogix",
|
||||
Arguments = Profile.BuildCliArgs(Port),
|
||||
RedirectStandardOutput = true,
|
||||
RedirectStandardError = true,
|
||||
UseShellExecute = false,
|
||||
@@ -75,7 +91,7 @@ public sealed class AbServerFixture : IAsyncLifetime
|
||||
|
||||
/// <summary>
|
||||
/// Locate <c>ab_server</c> on PATH. Returns <c>null</c> when missing — tests that
|
||||
/// depend on it should use <see cref="AbServerFact"/> so CI runs without the binary
|
||||
/// depend on it should use <see cref="AbServerFactAttribute"/> so CI runs without the binary
|
||||
/// simply skip rather than fail.
|
||||
/// </summary>
|
||||
public static string? LocateBinary()
|
||||
@@ -107,3 +123,17 @@ public sealed class AbServerFactAttribute : FactAttribute
|
||||
Skip = "ab_server not on PATH; install libplctag test binaries to run.";
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// <c>[Theory]</c>-equivalent that skips when <c>ab_server</c> is not on PATH. Pair with
|
||||
/// <c>[MemberData(nameof(KnownProfiles.All))]</c>-style providers to run one theory row per
|
||||
/// profile so a single test covers all four families.
|
||||
/// </summary>
|
||||
public sealed class AbServerTheoryAttribute : TheoryAttribute
|
||||
{
|
||||
public AbServerTheoryAttribute()
|
||||
{
|
||||
if (AbServerFixture.LocateBinary() is null)
|
||||
Skip = "ab_server not on PATH; install libplctag test binaries to run.";
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue