Recover stashed driver-gaps work from pre-v2-mxgw-merge working tree
Captures uncommitted work that lived in the working tree on
v2-mxgw-integration but was orthogonal to the migration. Stashed
during the v2-mxgw merge to master (2026-04-30) and replanted here on
a feature branch off master so it's git-visible rather than living in
the stash list.
Two distinct buckets:
1. Tracked fixture/config refinements (10 files, ~36 lines):
- scripts/e2e/test-opcuaclient.ps1
- src/ZB.MOM.WW.OtOpcUa.Admin/appsettings.json
- 5 docker-compose.yml under tests/.../IntegrationTests/Docker/
(AbCip, Modbus, OpcUaClient, S7)
- 4 fixture .cs files (AbServerFixture, ModbusSimulatorFixture,
OpcPlcFixture, Snap7ServerFixture)
2. Untracked driver-gaps queue artifacts (~8000 lines):
- docs/plans/{abcip,ablegacy,focas,opcuaclient,s7,twincat}-plan.md
— per-driver gap plans
- docs/featuregaps.md — cross-cutting analysis
- docs/v2/focas-deployment.md, docs/v2/implementation/focas-simulator-plan.md
- followup.md — auto/driver-gaps queue follow-ups
- scripts/queue/ — PR-queue automation tooling (12 files including
pr-manifest.yaml at 1473 lines)
This commit is a snapshot for recoverability — review and split into
focused PRs (or discard) before merging anywhere downstream.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -8,7 +8,7 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.AbCip.IntegrationTests;
|
||||
/// Reachability probe for the <c>ab_server</c> Docker container (libplctag's CIP
|
||||
/// simulator built via <c>Docker/Dockerfile</c>) or any real AB PLC the
|
||||
/// <c>AB_SERVER_ENDPOINT</c> env var points at. Parses
|
||||
/// <c>AB_SERVER_ENDPOINT</c> (default <c>localhost:44818</c>) + TCP-connects
|
||||
/// <c>AB_SERVER_ENDPOINT</c> (default <c>10.100.0.35:44818</c>) + TCP-connects
|
||||
/// once at fixture construction. Tests skip via <see cref="AbServerFactAttribute"/>
|
||||
/// / <see cref="AbServerTheoryAttribute"/> when the port isn't live, so
|
||||
/// <c>dotnet test</c> stays green on a fresh clone without Docker running.
|
||||
@@ -28,7 +28,7 @@ public sealed class AbServerFixture : IAsyncLifetime
|
||||
/// instantiate the fixture with the profile matching their compose-file service.</summary>
|
||||
public AbServerProfile Profile { get; }
|
||||
|
||||
public string Host { get; } = "127.0.0.1";
|
||||
public string Host { get; } = "10.100.0.35";
|
||||
public int Port { get; } = AbServerProfile.DefaultPort;
|
||||
|
||||
public AbServerFixture() : this(KnownProfiles.ControlLogix) { }
|
||||
@@ -59,7 +59,7 @@ public sealed class AbServerFixture : IAsyncLifetime
|
||||
TcpProbe(ResolveHost(), ResolvePort());
|
||||
|
||||
private static string ResolveHost() =>
|
||||
Environment.GetEnvironmentVariable(EndpointEnvVar)?.Split(':', 2)[0] ?? "127.0.0.1";
|
||||
Environment.GetEnvironmentVariable(EndpointEnvVar)?.Split(':', 2)[0] ?? "10.100.0.35";
|
||||
|
||||
private static int ResolvePort()
|
||||
{
|
||||
@@ -84,7 +84,7 @@ public sealed class AbServerFixture : IAsyncLifetime
|
||||
|
||||
/// <summary>
|
||||
/// <c>[Fact]</c>-equivalent that skips when ab_server isn't reachable — accepts a
|
||||
/// live Docker listener on <c>localhost:44818</c> or an <c>AB_SERVER_ENDPOINT</c>
|
||||
/// live Docker listener on <c>10.100.0.35:44818</c> or an <c>AB_SERVER_ENDPOINT</c>
|
||||
/// override pointing at a real PLC.
|
||||
/// </summary>
|
||||
public sealed class AbServerFactAttribute : FactAttribute
|
||||
|
||||
@@ -17,6 +17,8 @@ services:
|
||||
dockerfile: Dockerfile
|
||||
image: otopcua-ab-server:libplctag-release
|
||||
container_name: otopcua-ab-server-controllogix
|
||||
labels:
|
||||
project: lmxopcua
|
||||
restart: "no"
|
||||
ports:
|
||||
- "44818:44818"
|
||||
@@ -40,6 +42,8 @@ services:
|
||||
context: .
|
||||
dockerfile: Dockerfile
|
||||
container_name: otopcua-ab-server-compactlogix
|
||||
labels:
|
||||
project: lmxopcua
|
||||
restart: "no"
|
||||
ports:
|
||||
- "44818:44818"
|
||||
@@ -63,6 +67,8 @@ services:
|
||||
context: .
|
||||
dockerfile: Dockerfile
|
||||
container_name: otopcua-ab-server-micro800
|
||||
labels:
|
||||
project: lmxopcua
|
||||
restart: "no"
|
||||
ports:
|
||||
- "44818:44818"
|
||||
@@ -82,6 +88,8 @@ services:
|
||||
context: .
|
||||
dockerfile: Dockerfile
|
||||
container_name: otopcua-ab-server-guardlogix
|
||||
labels:
|
||||
project: lmxopcua
|
||||
restart: "no"
|
||||
ports:
|
||||
- "44818:44818"
|
||||
|
||||
@@ -17,6 +17,8 @@ services:
|
||||
dockerfile: Dockerfile
|
||||
image: otopcua-pymodbus:3.13.0
|
||||
container_name: otopcua-pymodbus-standard
|
||||
labels:
|
||||
project: lmxopcua
|
||||
restart: "no"
|
||||
ports:
|
||||
- "5020:5020"
|
||||
@@ -34,6 +36,8 @@ services:
|
||||
context: .
|
||||
dockerfile: Dockerfile
|
||||
container_name: otopcua-pymodbus-dl205
|
||||
labels:
|
||||
project: lmxopcua
|
||||
restart: "no"
|
||||
ports:
|
||||
- "5020:5020"
|
||||
@@ -51,6 +55,8 @@ services:
|
||||
context: .
|
||||
dockerfile: Dockerfile
|
||||
container_name: otopcua-pymodbus-mitsubishi
|
||||
labels:
|
||||
project: lmxopcua
|
||||
restart: "no"
|
||||
ports:
|
||||
- "5020:5020"
|
||||
@@ -68,6 +74,8 @@ services:
|
||||
context: .
|
||||
dockerfile: Dockerfile
|
||||
container_name: otopcua-pymodbus-s7_1500
|
||||
labels:
|
||||
project: lmxopcua
|
||||
restart: "no"
|
||||
ports:
|
||||
- "5020:5020"
|
||||
@@ -91,6 +99,8 @@ services:
|
||||
context: .
|
||||
dockerfile: Dockerfile
|
||||
container_name: otopcua-modbus-exception-injector
|
||||
labels:
|
||||
project: lmxopcua
|
||||
restart: "no"
|
||||
ports:
|
||||
- "5020:5020"
|
||||
|
||||
@@ -5,7 +5,7 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests;
|
||||
/// <summary>
|
||||
/// Reachability probe for a Modbus TCP simulator (pymodbus in Docker, see
|
||||
/// <c>Docker/docker-compose.yml</c>) or a real PLC. Parses
|
||||
/// <c>MODBUS_SIM_ENDPOINT</c> (default <c>localhost:5020</c> per PR 43) and TCP-connects once at
|
||||
/// <c>MODBUS_SIM_ENDPOINT</c> (default <c>10.100.0.35:5020</c>) and TCP-connects once at
|
||||
/// fixture construction. Each test checks <see cref="SkipReason"/> and calls
|
||||
/// <c>Assert.Skip</c> when the endpoint was unreachable, so a dev box without a running
|
||||
/// simulator still passes `dotnet test` cleanly — matches the Galaxy live-smoke pattern in
|
||||
@@ -30,7 +30,7 @@ public sealed class ModbusSimulatorFixture : IAsyncDisposable
|
||||
// Picking 5020 sidesteps the privileged-port admin requirement on Windows + matches the
|
||||
// port baked into the pymodbus simulator JSON profiles in Docker/profiles/. Override with
|
||||
// MODBUS_SIM_ENDPOINT to point at a real PLC on its native port 502.
|
||||
private const string DefaultEndpoint = "localhost:5020";
|
||||
private const string DefaultEndpoint = "10.100.0.35:5020";
|
||||
private const string EndpointEnvVar = "MODBUS_SIM_ENDPOINT";
|
||||
|
||||
public string Host { get; }
|
||||
|
||||
@@ -8,6 +8,8 @@ services:
|
||||
opc-plc:
|
||||
image: mcr.microsoft.com/iotedge/opc-plc:2.14.10
|
||||
container_name: otopcua-opc-plc
|
||||
labels:
|
||||
project: lmxopcua
|
||||
restart: "no"
|
||||
ports:
|
||||
- "50000:50000"
|
||||
|
||||
@@ -6,7 +6,7 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient.IntegrationTests;
|
||||
/// Reachability probe for an <c>opc-plc</c> simulator (Microsoft Industrial IoT's
|
||||
/// OPC UA PLC from <c>mcr.microsoft.com/iotedge/opc-plc</c>) or any real OPC UA
|
||||
/// server the <c>OPCUA_SIM_ENDPOINT</c> env var points at. Parses
|
||||
/// <c>OPCUA_SIM_ENDPOINT</c> (default <c>opc.tcp://localhost:50000</c>),
|
||||
/// <c>OPCUA_SIM_ENDPOINT</c> (default <c>opc.tcp://10.100.0.35:50000</c>),
|
||||
/// TCP-connects to the resolved host:port at collection init, and records a
|
||||
/// <see cref="SkipReason"/> on failure. Tests call <c>Assert.Skip</c> on that, so
|
||||
/// `dotnet test` stays green when Docker isn't running the simulator — mirrors the
|
||||
@@ -32,7 +32,7 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient.IntegrationTests;
|
||||
/// </remarks>
|
||||
public sealed class OpcPlcFixture : IAsyncDisposable
|
||||
{
|
||||
private const string DefaultEndpoint = "opc.tcp://localhost:50000";
|
||||
private const string DefaultEndpoint = "opc.tcp://10.100.0.35:50000";
|
||||
private const string EndpointEnvVar = "OPCUA_SIM_ENDPOINT";
|
||||
|
||||
/// <summary>Full <c>opc.tcp://host:port</c> URL the driver session should connect to.</summary>
|
||||
|
||||
@@ -14,6 +14,8 @@ services:
|
||||
dockerfile: Dockerfile
|
||||
image: otopcua-python-snap7:1.0
|
||||
container_name: otopcua-python-snap7-s7_1500
|
||||
labels:
|
||||
project: lmxopcua
|
||||
restart: "no"
|
||||
ports:
|
||||
- "1102:1102"
|
||||
|
||||
@@ -5,7 +5,7 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests;
|
||||
/// <summary>
|
||||
/// Reachability probe for the python-snap7 simulator Docker container (see
|
||||
/// <c>Docker/docker-compose.yml</c>) or a real S7 PLC. Parses <c>S7_SIM_ENDPOINT</c>
|
||||
/// (default <c>localhost:1102</c>) + TCP-connects once at fixture construction.
|
||||
/// (default <c>10.100.0.35:1102</c>) + TCP-connects once at fixture construction.
|
||||
/// Tests check <see cref="SkipReason"/> + call <c>Assert.Skip</c> when unreachable, so
|
||||
/// `dotnet test` stays green on a fresh box without the simulator installed —
|
||||
/// mirrors the <c>ModbusSimulatorFixture</c> pattern.
|
||||
@@ -35,7 +35,7 @@ public sealed class Snap7ServerFixture : IAsyncDisposable
|
||||
{
|
||||
// Default 1102 (non-privileged) matches Docker/server.py. Override with
|
||||
// S7_SIM_ENDPOINT to point at a real PLC on its native 102.
|
||||
private const string DefaultEndpoint = "localhost:1102";
|
||||
private const string DefaultEndpoint = "10.100.0.35:1102";
|
||||
private const string EndpointEnvVar = "S7_SIM_ENDPOINT";
|
||||
|
||||
public string Host { get; }
|
||||
|
||||
Reference in New Issue