feat(sql): opt-in writes — allowWrites + per-tag writable, single-row parameterised UPDATE (lmxopcua#753)
v2-ci / unit-tests (push) Waiting to run

allowWrites is no longer inert: SqlDriver implements IWritable, default off.

- Gates (outermost first): node Writable + WriteOperate (server), driver
  allowWrites, the tag's own TagConfig "writable": true (strict JSON boolean;
  anything else refuses the tag, and the deploy gate says why), and a model that
  names exactly one row — KeyValue, or WideRow by where-pair. topByTimestamp and
  Query are BadNotWritable.
- SqlWritePlanner: the only statement a write can become is
  UPDATE <table> SET <value col> = @v WHERE <key col> = @k, built from the
  catalog-gate-canonical identifiers (dialect-quoted) with value and key bound;
  value-before-key marker order so positional ODBC binds correctly. No authored
  write SQL, INSERT, UPSERT or procedure.
- Executed in a transaction that commits only when exactly one row was touched:
  0 rows -> BadNoData (never inserts), >1 -> rolled back, BadConfigurationError,
  unknown count -> rolled back, BadNotSupported. Bounded by operationTimeout;
  provider errors -> BadCommunicationError; health untouched.
- Discovery advertises Operate only where a write could succeed.
- AdminUI: driver form's Allow writes switch is live; tag editor gains a
  per-tag write switch; model validates writable strictly (parity corpus).
- Factory no longer warns "allowWrites ignored"; it logs whether writes are on.
- Tests: SqlWriteTests (planner SQL/bind order/injection/coercion, every gate,
  readback, absent key, two-row rollback, gate-rejected tag, discovery);
  MySqlReadTests write legs against InnoDB (keyed row only, two-row rollback,
  server-side grant refusal, default-off). Seed adds a setpoints table and the
  one UPDATE grant.

(lmxopcua#753)

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
This commit is contained in:
Joseph Doherty
2026-11-09 17:21:31 -05:00
parent 3c9ab4b668
commit 2331f7ed14
22 changed files with 916 additions and 75 deletions
@@ -6,8 +6,8 @@
-- backends. Two things are load-bearing:
--
-- 1. The suite connects as `otopcua`, which holds SELECT on `sqlpoll` and nothing else (plus EXECUTE on the
-- side-effect function, below). A MySQL "schema" is a database, and information_schema shows a principal
-- only the objects it holds a privilege on — so MySqlDialect.ListSchemasSql returning `sqlpoll` for this
-- side-effect function and UPDATE on the one write-target table, below). A MySQL "schema" is a database,
-- and information_schema shows a principal only the objects it holds a privilege on — so MySqlDialect.ListSchemasSql returning `sqlpoll` for this
-- login is the real provisioning check, not a superuser's view.
-- 2. Every identifier is lower case. The suite authors the table name in UPPER case and expects the catalog
-- gate to resolve it through a unique case-insensitive match: on Linux, MySQL table names are case-
@@ -65,9 +65,23 @@ BEGIN
END//
DELIMITER ;
-- Write target (lmxopcua#753): the ONLY table the suite login may UPDATE. `dup` deliberately holds two rows
-- for one key, so a write keyed on it matches two rows and must be rolled back. tag_values stays SELECT-only,
-- so a write tag pointed there proves the server's own grant refuses it.
CREATE TABLE setpoints (
tag_name varchar(128) NOT NULL,
sp_value double NULL
) ENGINE = InnoDB;
INSERT INTO setpoints (tag_name, sp_value) VALUES
('Line1.SpeedSp', 10.0),
('Line1.TempSp', 20.0),
('dup', 1.0),
('dup', 2.0);
-- ── the read-only login ──────────────────────────────────────────────────────────────────────
DROP USER IF EXISTS 'otopcua'@'%';
CREATE USER 'otopcua'@'%' IDENTIFIED BY '__APP_PASSWORD__';
GRANT SELECT ON sqlpoll.* TO 'otopcua'@'%';
GRANT EXECUTE ON FUNCTION sqlpoll.bump_counter TO 'otopcua'@'%';
GRANT UPDATE ON sqlpoll.setpoints TO 'otopcua'@'%';
FLUSH PRIVILEGES;
@@ -265,6 +265,88 @@ public sealed class MySqlReadTests
(await _my.ScalarAsync("SELECT COUNT(*) FROM sqlpoll.side_effects")).ShouldBe(0L);
}
// ---- writes (design §3.4) against a real server ----
/// <summary>All gates open: the UPDATE lands on exactly the keyed row, and the driver reads it back.</summary>
[Fact]
public async Task Write_realMySql_updatesTheKeyedRowOnly()
{
SkipUnlessLive();
await using var driver = await StartAsync(null, allowWrites: true,
Setpoint("Sql/Sp/Speed", "Line1.SpeedSp", writable: true));
var target = 10.0 + Random.Shared.Next(1, 1000);
(await WriteAsync(driver, "Sql/Sp/Speed", target)).ShouldBe(SqlStatusCodes.Good);
Convert.ToDouble(await _my.ScalarRawAsync("SELECT sp_value FROM sqlpoll.setpoints WHERE tag_name = 'Line1.SpeedSp'"),
CultureInfo.InvariantCulture).ShouldBe(target);
Convert.ToDouble(await _my.ScalarRawAsync("SELECT sp_value FROM sqlpoll.setpoints WHERE tag_name = 'Line1.TempSp'"),
CultureInfo.InvariantCulture).ShouldBe(20.0);
Convert.ToDouble((await driver.ReadAsync(["Sql/Sp/Speed"], TestContext.Current.CancellationToken))[0].Value,
CultureInfo.InvariantCulture).ShouldBe(target);
}
/// <summary>A key matching two rows is rolled back on InnoDB — neither row changes.</summary>
[Fact]
public async Task Write_realMySql_aKeyMatchingTwoRowsIsRolledBack()
{
SkipUnlessLive();
await using var driver = await StartAsync(null, allowWrites: true, Setpoint("Sql/Sp/Dup", "dup", writable: true));
(await WriteAsync(driver, "Sql/Sp/Dup", 99.0)).ShouldBe(SqlStatusCodes.BadConfigurationError);
(await _my.ScalarAsync("SELECT COUNT(*) FROM sqlpoll.setpoints WHERE tag_name = 'dup' AND sp_value = 99")).ShouldBe(0L);
}
/// <summary>
/// Defence in depth: with every driver gate open, a table the login holds no UPDATE on is refused by the
/// server itself (the provider error surfaces as BadCommunicationError) and the row is unchanged.
/// </summary>
[Fact]
public async Task Write_realMySql_aTableWithoutAnUpdateGrantIsRefusedByTheServer()
{
SkipUnlessLive();
await using var driver = await StartAsync(null, allowWrites: true, Tag("Sql/Kv/Speed", new JsonObject
{
["model"] = "KeyValue", ["table"] = MySqlFixture.Qualified("tag_values"), ["keyColumn"] = "tag_name",
["keyValue"] = MySqlFixture.PresentKey, ["valueColumn"] = "num_value", ["writable"] = true,
}));
(await WriteAsync(driver, "Sql/Kv/Speed", 1.0)).ShouldBe(SqlStatusCodes.BadCommunicationError);
Convert.ToDouble(await _my.ScalarRawAsync("SELECT num_value FROM sqlpoll.tag_values WHERE tag_name = 'Line1.Speed'"),
CultureInfo.InvariantCulture).ShouldBe(MySqlFixture.PresentValue);
}
/// <summary>The default: no allowWrites ⇒ refused before any connection, whatever the tag says.</summary>
[Fact]
public async Task Write_realMySql_withoutAllowWritesIsRefused()
{
SkipUnlessLive();
await using var driver = await StartAsync(null, allowWrites: false, Setpoint("Sql/Sp/Temp", "Line1.TempSp", writable: true));
(await WriteAsync(driver, "Sql/Sp/Temp", 77.0)).ShouldBe(SqlStatusCodes.BadNotWritable);
Convert.ToDouble(await _my.ScalarRawAsync("SELECT sp_value FROM sqlpoll.setpoints WHERE tag_name = 'Line1.TempSp'"),
CultureInfo.InvariantCulture).ShouldBe(20.0);
}
private static RawTagEntry Setpoint(string rawPath, string key, bool writable) => Tag(rawPath, new JsonObject
{
["model"] = "KeyValue",
["table"] = MySqlFixture.Qualified("setpoints"),
["keyColumn"] = "tag_name",
["keyValue"] = key,
["valueColumn"] = "sp_value",
["type"] = "Float64",
["writable"] = writable,
});
private static async Task<uint> WriteAsync(SqlDriver driver, string reference, object? value)
=> (await ((IWritable)driver).WriteAsync([new WriteRequest(reference, value)], TestContext.Current.CancellationToken))
.ShouldHaveSingleItem().StatusCode;
// ---- helpers ----
private void SkipUnlessLive()
@@ -274,13 +356,16 @@ public sealed class MySqlReadTests
private Task<SqlDriver> StartAsync(params RawTagEntry[] tags) => StartAsync(queriesJson: null, tags);
private Task<SqlDriver> StartAsync(string? queriesJson, params RawTagEntry[] tags)
=> StartAsync(queriesJson, allowWrites: false, tags);
/// <summary>
/// Builds and initializes a driver through the PRODUCTION factory (<c>provider: MySql</c>, the connection
/// string resolved from the fixture's <c>connectionStringRef</c> environment variable), so the suite
/// exercises <c>MySqlConnectorFactory.Instance</c> and the factory's own named-query validation exactly as a
/// deployed config would.
/// </summary>
private async Task<SqlDriver> StartAsync(string? queriesJson, params RawTagEntry[] tags)
private async Task<SqlDriver> StartAsync(string? queriesJson, bool allowWrites, params RawTagEntry[] tags)
{
var rawTags = new JsonArray();
foreach (var tag in tags)
@@ -302,6 +387,7 @@ public sealed class MySqlReadTests
["rawTags"] = rawTags,
};
if (queriesJson is not null) config["queries"] = JsonNode.Parse(queriesJson);
if (allowWrites) config["allowWrites"] = true;
var json = config.ToJsonString();
var driver = SqlDriverFactoryExtensions.CreateInstance("sql-mysql-integration", json);
@@ -433,6 +519,15 @@ public sealed class MySqlFixture : IAsyncLifetime
/// <param name="sql">The statement.</param>
/// <returns>The scalar, as a 64-bit integer when numeric.</returns>
public async Task<object?> ScalarAsync(string sql)
{
var value = await ScalarRawAsync(sql).ConfigureAwait(false);
return value is IConvertible and not string ? Convert.ToInt64(value, CultureInfo.InvariantCulture) : value;
}
/// <summary>Runs a scalar query as the fixture login and returns the provider's value unconverted.</summary>
/// <param name="sql">The statement.</param>
/// <returns>The scalar.</returns>
public async Task<object?> ScalarRawAsync(string sql)
{
var connection = new MySqlDialect().Factory.CreateConnection()
?? throw new InvalidOperationException("MySqlConnector returned no connection object.");
@@ -444,8 +539,7 @@ public sealed class MySqlFixture : IAsyncLifetime
await using (command.ConfigureAwait(false))
{
command.CommandText = sql;
var value = await command.ExecuteScalarAsync().ConfigureAwait(false);
return value is IConvertible and not string ? Convert.ToInt64(value, CultureInfo.InvariantCulture) : value;
return await command.ExecuteScalarAsync().ConfigureAwait(false);
}
}
}