feat(modbus): resolve equipment-tag refs (read + write) via EquipmentTagRefResolver
This commit is contained in:
@@ -0,0 +1,54 @@
|
|||||||
|
using System.Text.Json;
|
||||||
|
|
||||||
|
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus;
|
||||||
|
|
||||||
|
/// <summary>Parses an equipment tag's <c>TagConfig</c> JSON (the shape authored by the AdminUI
|
||||||
|
/// <c>ModbusTagConfigModel</c>) into a transient <see cref="ModbusTagDefinition"/> whose
|
||||||
|
/// <see cref="ModbusTagDefinition.Name"/> equals the reference string itself, so a value the
|
||||||
|
/// driver publishes back keys the runtime's forward router correctly.</summary>
|
||||||
|
public static class ModbusEquipmentTagParser
|
||||||
|
{
|
||||||
|
/// <summary>Attempts to parse an equipment-tag reference into a transient definition.</summary>
|
||||||
|
/// <param name="reference">The equipment tag's TagConfig JSON (also used as the def identity).</param>
|
||||||
|
/// <param name="def">The transient definition when parsing succeeds.</param>
|
||||||
|
/// <returns><see langword="true"/> when <paramref name="reference"/> is a Modbus address object.</returns>
|
||||||
|
public static bool TryParse(string reference, out ModbusTagDefinition def)
|
||||||
|
{
|
||||||
|
def = null!;
|
||||||
|
// Authored tag names never start with '{' (AdminUI name validation), so a leading brace marks an equipment-tag TagConfig blob.
|
||||||
|
if (string.IsNullOrWhiteSpace(reference) || reference[0] != '{') return false;
|
||||||
|
try
|
||||||
|
{
|
||||||
|
using var doc = JsonDocument.Parse(reference);
|
||||||
|
var root = doc.RootElement;
|
||||||
|
if (root.ValueKind != JsonValueKind.Object
|
||||||
|
|| !root.TryGetProperty("region", out _)
|
||||||
|
|| !root.TryGetProperty("address", out var addr))
|
||||||
|
return false;
|
||||||
|
if (addr.ValueKind != JsonValueKind.Number
|
||||||
|
|| !addr.TryGetInt32(out var address)
|
||||||
|
|| address < 0 || address > ushort.MaxValue)
|
||||||
|
return false;
|
||||||
|
var region = ReadEnum(root, "region", ModbusRegion.HoldingRegisters);
|
||||||
|
var dataType = ReadEnum(root, "dataType", ModbusDataType.Int16);
|
||||||
|
var byteOrder = ReadEnum(root, "byteOrder", ModbusByteOrder.BigEndian);
|
||||||
|
var bitIndex = (byte)ReadInt(root, "bitIndex");
|
||||||
|
var stringLength = (ushort)ReadInt(root, "stringLength");
|
||||||
|
def = new ModbusTagDefinition(
|
||||||
|
Name: reference, Region: region, Address: (ushort)address, DataType: dataType,
|
||||||
|
Writable: true, ByteOrder: byteOrder, BitIndex: bitIndex, StringLength: stringLength);
|
||||||
|
return true;
|
||||||
|
}
|
||||||
|
catch (JsonException) { return false; }
|
||||||
|
catch (FormatException) { return false; }
|
||||||
|
catch (InvalidOperationException) { return false; }
|
||||||
|
}
|
||||||
|
|
||||||
|
private static TEnum ReadEnum<TEnum>(JsonElement o, string name, TEnum fallback) where TEnum : struct, Enum
|
||||||
|
=> o.TryGetProperty(name, out var e) && e.ValueKind == JsonValueKind.String
|
||||||
|
&& Enum.TryParse<TEnum>(e.GetString(), ignoreCase: true, out var v) ? v : fallback;
|
||||||
|
|
||||||
|
private static int ReadInt(JsonElement o, string name)
|
||||||
|
=> o.TryGetProperty(name, out var e) && e.ValueKind == JsonValueKind.Number
|
||||||
|
&& e.TryGetInt32(out var v) ? v : 0;
|
||||||
|
}
|
||||||
@@ -34,6 +34,11 @@ public sealed class ModbusDriver
|
|||||||
|
|
||||||
private readonly Dictionary<string, ModbusTagDefinition> _tagsByName = new(StringComparer.OrdinalIgnoreCase);
|
private readonly Dictionary<string, ModbusTagDefinition> _tagsByName = new(StringComparer.OrdinalIgnoreCase);
|
||||||
|
|
||||||
|
// Resolves a read/write/subscribe fullReference to a tag definition, bridging the two
|
||||||
|
// authoring models: an authored tag-table entry (by name) OR an equipment tag whose
|
||||||
|
// reference is its raw TagConfig JSON (parsed once via ModbusEquipmentTagParser, cached).
|
||||||
|
private readonly EquipmentTagRefResolver<ModbusTagDefinition> _resolver;
|
||||||
|
|
||||||
// Last-published value per tag, keyed by FullReference. Used by ShouldPublish to apply
|
// Last-published value per tag, keyed by FullReference. Used by ShouldPublish to apply
|
||||||
// the deadband filter. Stored as object so all numeric types share one map; the comparison
|
// the deadband filter. Stored as object so all numeric types share one map; the comparison
|
||||||
// does a typed cast inside.
|
// does a typed cast inside.
|
||||||
@@ -111,6 +116,9 @@ public sealed class ModbusDriver
|
|||||||
_options = options;
|
_options = options;
|
||||||
_driverInstanceId = driverInstanceId;
|
_driverInstanceId = driverInstanceId;
|
||||||
_logger = logger ?? NullLogger<ModbusDriver>.Instance;
|
_logger = logger ?? NullLogger<ModbusDriver>.Instance;
|
||||||
|
_resolver = new EquipmentTagRefResolver<ModbusTagDefinition>(
|
||||||
|
r => _tagsByName.TryGetValue(r, out var t) ? t : null,
|
||||||
|
r => ModbusEquipmentTagParser.TryParse(r, out var d) ? d : null);
|
||||||
_transportFactory = transportFactory
|
_transportFactory = transportFactory
|
||||||
?? (o => new ModbusTcpTransport(
|
?? (o => new ModbusTcpTransport(
|
||||||
o.Host, o.Port, o.Timeout, o.AutoReconnect,
|
o.Host, o.Port, o.Timeout, o.AutoReconnect,
|
||||||
@@ -148,7 +156,7 @@ public sealed class ModbusDriver
|
|||||||
|
|
||||||
private bool ShouldPublish(string tagRef, DataValueSnapshot snapshot)
|
private bool ShouldPublish(string tagRef, DataValueSnapshot snapshot)
|
||||||
{
|
{
|
||||||
if (!_tagsByName.TryGetValue(tagRef, out var tag) || tag.Deadband is null) return true;
|
if (!_resolver.TryResolve(tagRef, out var tag) || tag.Deadband is null) return true;
|
||||||
if (snapshot.Value is null) return true;
|
if (snapshot.Value is null) return true;
|
||||||
// Deadband only applies to numeric scalar types — array / Bool / String publishes
|
// Deadband only applies to numeric scalar types — array / Bool / String publishes
|
||||||
// unconditionally. Easier to special-case skip than to enumerate the supported types.
|
// unconditionally. Easier to special-case skip than to enumerate the supported types.
|
||||||
@@ -297,7 +305,7 @@ public sealed class ModbusDriver
|
|||||||
for (var i = 0; i < fullReferences.Count; i++)
|
for (var i = 0; i < fullReferences.Count; i++)
|
||||||
{
|
{
|
||||||
if (coalesced.Contains(i)) continue;
|
if (coalesced.Contains(i)) continue;
|
||||||
if (!_tagsByName.TryGetValue(fullReferences[i], out var tag))
|
if (!_resolver.TryResolve(fullReferences[i], out var tag))
|
||||||
{
|
{
|
||||||
results[i] = new DataValueSnapshot(null, StatusBadNodeIdUnknown, null, now);
|
results[i] = new DataValueSnapshot(null, StatusBadNodeIdUnknown, null, now);
|
||||||
continue;
|
continue;
|
||||||
@@ -711,7 +719,7 @@ public sealed class ModbusDriver
|
|||||||
var eligible = new List<(int Index, string Ref, ModbusTagDefinition Tag)>();
|
var eligible = new List<(int Index, string Ref, ModbusTagDefinition Tag)>();
|
||||||
for (var i = 0; i < fullReferences.Count; i++)
|
for (var i = 0; i < fullReferences.Count; i++)
|
||||||
{
|
{
|
||||||
if (!_tagsByName.TryGetValue(fullReferences[i], out var tag)) continue;
|
if (!_resolver.TryResolve(fullReferences[i], out var tag)) continue;
|
||||||
if (tag.CoalesceProhibited) continue;
|
if (tag.CoalesceProhibited) continue;
|
||||||
if (tag.ArrayCount.HasValue) continue;
|
if (tag.ArrayCount.HasValue) continue;
|
||||||
if (tag.Region is not (ModbusRegion.HoldingRegisters or ModbusRegion.InputRegisters)) continue;
|
if (tag.Region is not (ModbusRegion.HoldingRegisters or ModbusRegion.InputRegisters)) continue;
|
||||||
@@ -931,7 +939,7 @@ public sealed class ModbusDriver
|
|||||||
for (var i = 0; i < writes.Count; i++)
|
for (var i = 0; i < writes.Count; i++)
|
||||||
{
|
{
|
||||||
var w = writes[i];
|
var w = writes[i];
|
||||||
if (!_tagsByName.TryGetValue(w.FullReference, out var tag))
|
if (!_resolver.TryResolve(w.FullReference, out var tag))
|
||||||
{
|
{
|
||||||
results[i] = new WriteResult(StatusBadNodeIdUnknown);
|
results[i] = new WriteResult(StatusBadNodeIdUnknown);
|
||||||
continue;
|
continue;
|
||||||
@@ -1617,6 +1625,7 @@ public sealed class ModbusDriver
|
|||||||
_reprobeCts = null;
|
_reprobeCts = null;
|
||||||
|
|
||||||
_tagsByName.Clear();
|
_tagsByName.Clear();
|
||||||
|
_resolver.Clear(); // drop transient equipment-tag parses so a config change re-parses
|
||||||
_lastPublishedByRef.Clear();
|
_lastPublishedByRef.Clear();
|
||||||
lock (_lastWrittenLock) _lastWrittenByRef.Clear();
|
lock (_lastWrittenLock) _lastWrittenByRef.Clear();
|
||||||
lock (_autoProhibitedLock) _autoProhibited.Clear();
|
lock (_autoProhibitedLock) _autoProhibited.Clear();
|
||||||
|
|||||||
@@ -0,0 +1,61 @@
|
|||||||
|
using Shouldly;
|
||||||
|
using Xunit;
|
||||||
|
using ZB.MOM.WW.OtOpcUa.Driver.Modbus;
|
||||||
|
|
||||||
|
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
|
||||||
|
|
||||||
|
[Trait("Category", "Unit")]
|
||||||
|
public class ModbusEquipmentTagTests
|
||||||
|
{
|
||||||
|
[Fact]
|
||||||
|
public void Parses_equipment_tagconfig_into_a_transient_definition()
|
||||||
|
{
|
||||||
|
var json = """{"region":"HoldingRegisters","address":40001,"dataType":"UInt16","byteOrder":"BigEndian","bitIndex":0,"stringLength":0}""";
|
||||||
|
ModbusEquipmentTagParser.TryParse(json, out var def).ShouldBeTrue();
|
||||||
|
def!.Name.ShouldBe(json);
|
||||||
|
def.Region.ShouldBe(ModbusRegion.HoldingRegisters);
|
||||||
|
def.Address.ShouldBe((ushort)40001);
|
||||||
|
def.DataType.ShouldBe(ModbusDataType.UInt16);
|
||||||
|
}
|
||||||
|
|
||||||
|
[Fact]
|
||||||
|
public void Rejects_a_non_address_blob()
|
||||||
|
=> ModbusEquipmentTagParser.TryParse("""{"FullName":"x"}""", out _).ShouldBeFalse();
|
||||||
|
|
||||||
|
[Fact]
|
||||||
|
public void Rejects_garbage()
|
||||||
|
=> ModbusEquipmentTagParser.TryParse("not json", out _).ShouldBeFalse();
|
||||||
|
|
||||||
|
[Fact]
|
||||||
|
public void Rejects_address_as_a_json_string()
|
||||||
|
=> ModbusEquipmentTagParser.TryParse(
|
||||||
|
"""{"region":"HoldingRegisters","address":"40001","dataType":"UInt16"}""", out _).ShouldBeFalse();
|
||||||
|
|
||||||
|
[Fact]
|
||||||
|
public void Rejects_address_out_of_ushort_range()
|
||||||
|
=> ModbusEquipmentTagParser.TryParse(
|
||||||
|
"""{"region":"HoldingRegisters","address":70000,"dataType":"UInt16"}""", out _).ShouldBeFalse();
|
||||||
|
|
||||||
|
/// <summary>
|
||||||
|
/// End-to-end driver-level proof: a Modbus driver with NO authored tags can still read an
|
||||||
|
/// equipment-tag ref (the raw TagConfig JSON) — the resolver parses it into a transient
|
||||||
|
/// definition and the read goes to the wire instead of returning BadNodeIdUnknown.
|
||||||
|
/// </summary>
|
||||||
|
[Fact]
|
||||||
|
public async Task Driver_resolves_an_equipment_ref_and_reads_instead_of_BadNodeIdUnknown()
|
||||||
|
{
|
||||||
|
// Address 10 fits the fake transport's 256-register bank (40001 would overflow it).
|
||||||
|
var json = """{"region":"HoldingRegisters","address":10,"dataType":"UInt16","byteOrder":"BigEndian","bitIndex":0,"stringLength":0}""";
|
||||||
|
var fake = new ModbusDriverTests.FakeTransport();
|
||||||
|
var opts = new ModbusDriverOptions { Host = "fake", Tags = [] };
|
||||||
|
var drv = new ModbusDriver(opts, "modbus-eq", _ => fake);
|
||||||
|
await drv.InitializeAsync("{}", CancellationToken.None);
|
||||||
|
fake.HoldingRegisters[10] = 4242;
|
||||||
|
|
||||||
|
var r = await drv.ReadAsync([json], CancellationToken.None);
|
||||||
|
|
||||||
|
r[0].StatusCode.ShouldBe(0u);
|
||||||
|
r[0].StatusCode.ShouldNotBe(0x80340000u); // not BadNodeIdUnknown
|
||||||
|
r[0].Value.ShouldBe((ushort)4242);
|
||||||
|
}
|
||||||
|
}
|
||||||
Reference in New Issue