fix(opcua): parallel UserName activations wait for a slot instead of being refused (#833)

A legitimate consumer opening several keyed sessions at once from one key
(e.g. a ScadaBridge site node behind one NAT IP on a None endpoint) must
never see BadUserAccessDenied for parallelism. BeginAsync now hands out at
most MaxFailedAttempts - recordedFailures verification slots per key;
further activations queue FIFO and are woken as slots free. A waiter is
refused only when the key locks out (never reaching the authenticator) or,
uncounted, after OpcUa:CredentialLockout:SlotWaitSeconds (default 10,
BadTimeout). Cancelled waiters are dequeued; pruning accounts for waiters.
The security property is unchanged: no more than MaxFailedAttempts
unverified guesses in progress-or-failed per window.
This commit is contained in:
Joseph Doherty
2026-11-11 02:43:38 -05:00
parent 61b9adeb9c
commit 2314a53842
9 changed files with 397 additions and 159 deletions
@@ -79,4 +79,17 @@ public sealed class OpcUaApplicationHostOptionsValidatorTests
result.Succeeded.ShouldBe(valid);
if (!valid) result.Failures!.ShouldContain(f => f.Contains("OpcUa:CredentialLockout:LockoutSeconds"));
}
/// <summary>#833 review: the slot wait must be positive while the lockout is enabled.</summary>
[Fact]
public void Credential_lockout_slot_wait_must_be_positive_while_enabled()
{
var result = Sut.Validate(null, new OpcUaApplicationHostOptions
{
CredentialLockout = new ZB.MOM.WW.OtOpcUa.OpcUaServer.Security.OpcUaCredentialLockoutOptions { SlotWaitSeconds = 0 },
});
result.Failed.ShouldBeTrue();
result.Failures!.ShouldContain(f => f.Contains("OpcUa:CredentialLockout:SlotWaitSeconds"));
}
}