fix(opcua): parallel UserName activations wait for a slot instead of being refused (#833)
A legitimate consumer opening several keyed sessions at once from one key (e.g. a ScadaBridge site node behind one NAT IP on a None endpoint) must never see BadUserAccessDenied for parallelism. BeginAsync now hands out at most MaxFailedAttempts - recordedFailures verification slots per key; further activations queue FIFO and are woken as slots free. A waiter is refused only when the key locks out (never reaching the authenticator) or, uncounted, after OpcUa:CredentialLockout:SlotWaitSeconds (default 10, BadTimeout). Cancelled waiters are dequeued; pruning accounts for waiters. The security property is unchanged: no more than MaxFailedAttempts unverified guesses in progress-or-failed per window.
This commit is contained in:
+3
-2
@@ -34,8 +34,9 @@ public sealed class OpcUaApplicationHostOptionsValidator : OptionsValidatorBase<
|
||||
// nothing, a zero FailureWindowSeconds would never accumulate. MaxFailedAttempts <= 0 disables it.
|
||||
var lockout = o.CredentialLockout;
|
||||
builder.RequireThat(lockout is null || lockout.MaxFailedAttempts <= 0
|
||||
|| (lockout.LockoutSeconds > 0 && lockout.FailureWindowSeconds > 0),
|
||||
"OpcUa:CredentialLockout:LockoutSeconds and OpcUa:CredentialLockout:FailureWindowSeconds must both be "
|
||||
|| (lockout.LockoutSeconds > 0 && lockout.FailureWindowSeconds > 0 && lockout.SlotWaitSeconds > 0),
|
||||
"OpcUa:CredentialLockout:LockoutSeconds, OpcUa:CredentialLockout:FailureWindowSeconds and "
|
||||
+ "OpcUa:CredentialLockout:SlotWaitSeconds must all be "
|
||||
+ "greater than 0 while OpcUa:CredentialLockout:MaxFailedAttempts is greater than 0 (set "
|
||||
+ "MaxFailedAttempts to 0 to disable the lockout)");
|
||||
}
|
||||
|
||||
Reference in New Issue