Docs audit — fill gaps so the top-level docs/ reference matches shipped code
Audit of docs/ against src/ surfaced shipped features without current-reference coverage (FOCAS CLI, Core.Scripting+VirtualTags, Core.ScriptedAlarms, Core.AlarmHistorian), an out-of-date driver count + capability matrix, ADR-002's virtual-tag dispatch not reflected in data-path docs, broken cross-references, and OpcUaServerReqs declaring OPC-020..022 that were never scoped. This commit closes all of those so operators + integrators can stay inside docs/ without falling back to v2/implementation/. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
158
docs/Driver.FOCAS.Cli.md
Normal file
158
docs/Driver.FOCAS.Cli.md
Normal file
@@ -0,0 +1,158 @@
|
||||
# `otopcua-focas-cli` — Fanuc FOCAS test client
|
||||
|
||||
Ad-hoc probe / read / write / subscribe tool for Fanuc CNCs via the FOCAS/2
|
||||
protocol. Uses the **same** `FocasDriver` the OtOpcUa server does — PMC R/G/F
|
||||
file registers, axis bits, parameters, and macro variables — all through
|
||||
`FocasAddressParser` syntax.
|
||||
|
||||
Sixth of the driver test-client CLIs, added alongside the Tier-C isolation
|
||||
work tracked in task #220.
|
||||
|
||||
## Architecture note
|
||||
|
||||
FOCAS is a Tier-C driver: `Fwlib32.dll` is a proprietary 32-bit Fanuc library
|
||||
with a documented habit of crashing its hosting process on network errors.
|
||||
The target runtime deployment splits the driver into an in-process
|
||||
`FocasProxyDriver` (.NET 10 x64) and an out-of-process `Driver.FOCAS.Host`
|
||||
(.NET 4.8 x86 Windows service) that owns the DLL — see
|
||||
[v2/implementation/focas-isolation-plan.md](v2/implementation/focas-isolation-plan.md)
|
||||
and
|
||||
[v2/implementation/phase-6-1-resilience-and-observability.md](v2/implementation/phase-6-1-resilience-and-observability.md)
|
||||
for topology + supervisor / respawn / back-pressure design.
|
||||
|
||||
The CLI skips the proxy and loads `FocasDriver` directly (via
|
||||
`FwlibFocasClientFactory`, which P/Invokes `Fwlib32.dll` in the CLI's own
|
||||
process). There is **no public simulator** for FOCAS; a meaningful probe
|
||||
requires a real CNC + a licensed `Fwlib32.dll` on `PATH` (or next to the
|
||||
executable). On a dev box without the DLL, every wire call surfaces as
|
||||
`BadCommunicationError` — still useful as a "CLI wire-up is correct" signal.
|
||||
|
||||
## Build + run
|
||||
|
||||
```powershell
|
||||
dotnet build src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli
|
||||
dotnet run --project src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli -- --help
|
||||
```
|
||||
|
||||
Or publish a self-contained binary:
|
||||
|
||||
```powershell
|
||||
dotnet publish src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli -c Release -o publish/focas-cli
|
||||
publish/focas-cli/otopcua-focas-cli.exe --help
|
||||
```
|
||||
|
||||
## Common flags
|
||||
|
||||
Every command accepts:
|
||||
|
||||
| Flag | Default | Purpose |
|
||||
|---|---|---|
|
||||
| `-h` / `--cnc-host` | **required** | CNC IP address or hostname |
|
||||
| `-p` / `--cnc-port` | `8193` | FOCAS TCP port (FOCAS-over-EIP default) |
|
||||
| `-s` / `--series` | `Unknown` | CNC series — `Unknown` / `Zero_i_D` / `Zero_i_F` / `Zero_i_MF` / `Zero_i_TF` / `Sixteen_i` / `Thirty_i` / `ThirtyOne_i` / `ThirtyTwo_i` / `PowerMotion_i` |
|
||||
| `--timeout-ms` | `2000` | Per-operation timeout |
|
||||
| `--verbose` | off | Serilog debug output |
|
||||
|
||||
## Addressing
|
||||
|
||||
`FocasAddressParser` syntax — the same format the server + `FocasTagDefinition`
|
||||
use. Common shapes:
|
||||
|
||||
| Address | Meaning |
|
||||
|---|---|
|
||||
| `R100` | PMC R-file word register 100 |
|
||||
| `X0.0` | PMC X-file bit 0 of byte 0 |
|
||||
| `G50.3` | PMC G-file bit 3 of byte 50 |
|
||||
| `F1.4` | PMC F-file bit 4 of byte 1 |
|
||||
| `PARAM:1815/0` | Parameter 1815, axis 0 |
|
||||
| `MACRO:500` | Macro variable 500 |
|
||||
|
||||
## Data types
|
||||
|
||||
`Bit`, `Byte`, `Int16`, `Int32`, `Float32`, `Float64`, `String`. Default is
|
||||
`Int16` (matches PMC R-file word width).
|
||||
|
||||
## Commands
|
||||
|
||||
### `probe` — is the CNC reachable?
|
||||
|
||||
Opens a FOCAS session, reads one sample address, prints driver health.
|
||||
|
||||
```powershell
|
||||
# Default: read R100 as Int16
|
||||
otopcua-focas-cli probe -h 192.168.1.50
|
||||
|
||||
# Explicit series + address
|
||||
otopcua-focas-cli probe -h 192.168.1.50 -s ThirtyOne_i --address R200 --type Int16
|
||||
```
|
||||
|
||||
### `read` — single address
|
||||
|
||||
```powershell
|
||||
# PMC R-file word
|
||||
otopcua-focas-cli read -h 192.168.1.50 -a R100 -t Int16
|
||||
|
||||
# PMC X-bit
|
||||
otopcua-focas-cli read -h 192.168.1.50 -a X0.0 -t Bit
|
||||
|
||||
# Parameter (axis 0)
|
||||
otopcua-focas-cli read -h 192.168.1.50 -a PARAM:1815/0 -t Int32
|
||||
|
||||
# Macro variable
|
||||
otopcua-focas-cli read -h 192.168.1.50 -a MACRO:500 -t Float64
|
||||
```
|
||||
|
||||
### `write` — single value
|
||||
|
||||
Values parse per `--type` with invariant culture. Booleans accept
|
||||
`true` / `false` / `1` / `0` / `yes` / `no` / `on` / `off`.
|
||||
|
||||
```powershell
|
||||
otopcua-focas-cli write -h 192.168.1.50 -a R100 -t Int16 -v 42
|
||||
otopcua-focas-cli write -h 192.168.1.50 -a G50.3 -t Bit -v on
|
||||
otopcua-focas-cli write -h 192.168.1.50 -a MACRO:500 -t Float64 -v 3.14
|
||||
```
|
||||
|
||||
PMC G/R writes land on a running machine — be careful which file you hit.
|
||||
Parameter writes may require the CNC to be in MDI mode with the
|
||||
parameter-write switch enabled.
|
||||
|
||||
**Writes are non-idempotent by default** — a timeout after the CNC already
|
||||
applied the write will NOT auto-retry (plan decisions #44 + #45).
|
||||
|
||||
### `subscribe` — watch an address until Ctrl+C
|
||||
|
||||
FOCAS has no push model; the shared `PollGroupEngine` handles the tick
|
||||
loop.
|
||||
|
||||
```powershell
|
||||
otopcua-focas-cli subscribe -h 192.168.1.50 -a R100 -t Int16 -i 500
|
||||
```
|
||||
|
||||
## Output format
|
||||
|
||||
Identical to the other driver CLIs via `SnapshotFormatter`:
|
||||
|
||||
- `probe` / `read` emit a multi-line block: `Tag / Value / Status /
|
||||
Source Time / Server Time`. `probe` prefixes it with `CNC`, `Series`,
|
||||
`Health`, and `Last error` lines.
|
||||
- `write` emits one line: `Write <address>: 0x... (Good |
|
||||
BadCommunicationError | …)`.
|
||||
- `subscribe` emits one line per change: `[HH:mm:ss.fff] <address> =
|
||||
<value> (<status>)`.
|
||||
|
||||
## Typical workflows
|
||||
|
||||
**"Is the CNC alive?"** → `probe`.
|
||||
|
||||
**"Does my parameter write land?"** → `write` + `read` back against the
|
||||
same address. Check the parameter-write switch + MDI mode if the write
|
||||
fails.
|
||||
|
||||
**"Why did this macro flip?"** → `subscribe` to the macro, let the
|
||||
operator reproduce the cycle, watch the HH:mm:ss.fff timeline.
|
||||
|
||||
**"Is the Fwlib32 DLL wired up?"** → `probe` against any host. A
|
||||
`DllNotFoundException` surfacing as `BadCommunicationError` with a
|
||||
matching `Last error` line means the driver is loading but the DLL is
|
||||
missing; anything else means a transport-layer problem.
|
||||
Reference in New Issue