refactor(runtime): delete the dead in-place ApplyDelta seam; config change = respawn only (#665)
Since #516 a DriverConfig change is stop + respawn, so DriverSpawnPlan.ToApplyDelta was always empty and the in-place path had no producer. #663 and #664 were both latent bugs in it. This deletes it: - host: ApplyChildDelta, _pendingDelta, HandleApplyResult and HandleDeltaApplied - plan: DriverSpawnPlan.ToApplyDelta - actor: the ApplyDelta, ApplyResult and DeltaApplied messages, the Connected reinit handler and the mid-connect AdoptConfigDuringInit - tests: the actor tests that drove the seam IDriver.ReinitializeAsync and each driver's implementation and unit tests stay. Comments and docs that cited AdoptConfigDuringInit as the reason a driver must release prior state at init now cite the IDriver contract and overlapping retries, which still apply. Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
This commit is contained in:
@@ -983,9 +983,9 @@ public sealed class MqttDriver
|
||||
// published below (_connection, _primaryHost) are IAsyncDisposable and were previously
|
||||
// overwritten, so a second initialize on a live driver stranded a connected, supervised
|
||||
// broker session — plus a whole second primary-host connection — that no later dispose
|
||||
// could reach. Reachable without any teardown of ours: DriverInstanceActor re-runs
|
||||
// InitializeAsync with no ShutdownAsync when an ApplyDelta lands while the driver is in
|
||||
// Connecting/Reconnecting (AdoptConfigDuringInit). Idempotent, so the ReinitializeAsync
|
||||
// could reach. The IDriver contract lets a caller
|
||||
// re-initialise a live driver without ShutdownAsync, and a reconnect retry can overlap a running
|
||||
// attempt. Idempotent, so the ReinitializeAsync
|
||||
// rebuild branch calling TeardownAsync first costs a no-op, and a first initialize sees
|
||||
// three nulls.
|
||||
await TeardownAsync().ConfigureAwait(false);
|
||||
|
||||
Reference in New Issue