fix(deploy): count removed equipment tags/vtags in RemovedNodes (H1a review follow-up)
This commit is contained in:
@@ -67,6 +67,10 @@ public sealed class Phase7Applier
|
|||||||
SafeWriteAlarmCondition(alarm.ScriptedAlarmId, RemovedConditionState, ts);
|
SafeWriteAlarmCondition(alarm.ScriptedAlarmId, RemovedConditionState, ts);
|
||||||
removedCount++;
|
removedCount++;
|
||||||
}
|
}
|
||||||
|
// Removed equipment tags / VirtualTags are plain variable nodes (no Part 9 condition to write
|
||||||
|
// before tear-down), but they ARE real removals — count them so Phase7ApplyOutcome.RemovedNodes
|
||||||
|
// is accurate on a removed-tag-only deploy, which now reaches the rebuild path below.
|
||||||
|
removedCount += plan.RemovedEquipmentTags.Count + plan.RemovedEquipmentVirtualTags.Count;
|
||||||
|
|
||||||
var changedCount =
|
var changedCount =
|
||||||
plan.ChangedEquipment.Count + plan.ChangedDrivers.Count + plan.ChangedAlarms.Count +
|
plan.ChangedEquipment.Count + plan.ChangedDrivers.Count + plan.ChangedAlarms.Count +
|
||||||
|
|||||||
@@ -622,6 +622,50 @@ public sealed class Phase7ApplierTests
|
|||||||
sink.RebuildCalls.ShouldBe(0);
|
sink.RebuildCalls.ShouldBe(0);
|
||||||
}
|
}
|
||||||
|
|
||||||
|
/// <summary>H1a (review follow-up) — a deploy that ONLY removes existing equipment tag / VirtualTag
|
||||||
|
/// nodes must rebuild AND tally the removals. Removed tags/VirtualTags are plain variable nodes (no
|
||||||
|
/// Part 9 condition to write), so before the fix they reached the rebuild path but were never added
|
||||||
|
/// to <c>removedCount</c> — <c>Phase7ApplyOutcome.RemovedNodes</c> reported 0, a misleading audit
|
||||||
|
/// entry. This pins both the rebuild and the accurate count.</summary>
|
||||||
|
[Fact]
|
||||||
|
public void Removed_equipment_tags_and_virtual_tags_only_rebuild_and_are_counted()
|
||||||
|
{
|
||||||
|
var sink = new RecordingSink();
|
||||||
|
var applier = new Phase7Applier(sink, NullLogger<Phase7Applier>.Instance);
|
||||||
|
|
||||||
|
var previous = new Phase7CompositionResult(
|
||||||
|
Array.Empty<EquipmentNode>(), Array.Empty<DriverInstancePlan>(), Array.Empty<ScriptedAlarmPlan>())
|
||||||
|
{
|
||||||
|
EquipmentTags = new[]
|
||||||
|
{
|
||||||
|
new EquipmentTagPlan("tag-1", "eq-1", "drv", FolderPath: "", Name: "Speed", DataType: "Float", FullName: "40001", Writable: false, Alarm: null),
|
||||||
|
},
|
||||||
|
EquipmentVirtualTags = new[]
|
||||||
|
{
|
||||||
|
new EquipmentVirtualTagPlan("vt-1", "eq-1", FolderPath: "", Name: "Efficiency", DataType: "Float64",
|
||||||
|
Expression: "ctx.GetTag(\"a\")", DependencyRefs: new[] { "a" }),
|
||||||
|
},
|
||||||
|
};
|
||||||
|
var next = new Phase7CompositionResult(
|
||||||
|
Array.Empty<EquipmentNode>(), Array.Empty<DriverInstancePlan>(), Array.Empty<ScriptedAlarmPlan>());
|
||||||
|
|
||||||
|
var plan = Phase7Planner.Compute(previous, next);
|
||||||
|
|
||||||
|
// Guard the arrange: ONLY the two Removed sets are populated.
|
||||||
|
plan.RemovedEquipmentTags.Count.ShouldBe(1);
|
||||||
|
plan.RemovedEquipmentVirtualTags.Count.ShouldBe(1);
|
||||||
|
plan.AddedEquipmentTags.ShouldBeEmpty();
|
||||||
|
plan.ChangedEquipmentTags.ShouldBeEmpty();
|
||||||
|
plan.RemovedEquipment.ShouldBeEmpty();
|
||||||
|
plan.RemovedAlarms.ShouldBeEmpty();
|
||||||
|
|
||||||
|
var outcome = applier.Apply(plan);
|
||||||
|
|
||||||
|
outcome.RebuildCalled.ShouldBeTrue();
|
||||||
|
sink.RebuildCalls.ShouldBe(1);
|
||||||
|
outcome.RemovedNodes.ShouldBe(2); // both removals counted (was 0 before the fix)
|
||||||
|
}
|
||||||
|
|
||||||
private static Phase7CompositionResult CompositionWithTags(params EquipmentTagPlan[] tags) =>
|
private static Phase7CompositionResult CompositionWithTags(params EquipmentTagPlan[] tags) =>
|
||||||
new(
|
new(
|
||||||
Array.Empty<EquipmentNode>(), Array.Empty<DriverInstancePlan>(), Array.Empty<ScriptedAlarmPlan>())
|
Array.Empty<EquipmentNode>(), Array.Empty<DriverInstancePlan>(), Array.Empty<ScriptedAlarmPlan>())
|
||||||
|
|||||||