@@ -53,3 +53,56 @@ giant request. Typical FANUC ring buffers cap at ~100 entries; the default
|
||||
- Tier-C Fwlib32 backend short-circuits the packed-buffer decoder by
|
||||
surfacing the FWLIB struct fields directly into
|
||||
`FocasAlarmHistoryEntry`.
|
||||
|
||||
## Writes (opt-in, off by default) — issue #268, plan PR F4-a
|
||||
|
||||
Writes ship behind two independent opt-ins. Both default off so a freshly
|
||||
deployed FOCAS driver is read-only until the deployment makes a deliberate
|
||||
choice. Decision record: [`docs/v2/decisions.md`](../v2/decisions.md) →
|
||||
"FOCAS write-path opt-in".
|
||||
|
||||
| Knob | Default | Effect when off |
|
||||
| --- | --- | --- |
|
||||
| `FocasDriverOptions.Writes.Enabled` *(driver-level master switch)* | `false` | Every entry in a `WriteAsync` batch short-circuits to `BadNotWritable` with status text `writes disabled at driver level`. Wire client never gets touched. |
|
||||
| `FocasTagDefinition.Writable` *(per-tag opt-in)* | `false` | The per-tag check returns `BadNotWritable` for that tag even when the driver-level flag is on. |
|
||||
|
||||
### Config shape
|
||||
|
||||
```jsonc
|
||||
{
|
||||
"Writes": { "Enabled": true },
|
||||
"Tags": [
|
||||
{ "Name": "RPM", "Address": "PARAM:1815", "DataType": "Int32",
|
||||
"Writable": true, "WriteIdempotent": false }
|
||||
]
|
||||
}
|
||||
```
|
||||
|
||||
`WriteIdempotent` is plumbed through Polly retry by the server-layer
|
||||
`CapabilityInvoker.ExecuteWriteAsync`. When `false` (default), failed writes
|
||||
are NOT auto-retried per plan decisions #44/#45 — a timeout that fires after
|
||||
the CNC already accepted the write would otherwise risk a duplicate
|
||||
non-idempotent action (alarm acks, M-code pulses, recipe steps). Flip
|
||||
`WriteIdempotent` on per tag for genuinely-idempotent writes (a parameter
|
||||
value that the operator simply wants forced to a target).
|
||||
|
||||
### Status-code semantics post-F4-a
|
||||
|
||||
- `BadNotWritable` — driver-level `Writes.Enabled = false`, OR per-tag
|
||||
`Writable = false`. Two distinct paths, same status code.
|
||||
- `BadNotSupported` — both opt-ins flipped on, but the wire client doesn't
|
||||
yet implement the kind being written. F4-a wires the dispatch surface;
|
||||
F4-b/c land the actual macro / parameter / PMC writes for unimplemented
|
||||
kinds, replacing those `BadNotSupported` responses with real wire calls.
|
||||
- `BadNodeIdUnknown` — full-reference doesn't match any configured
|
||||
`FocasTagDefinition.Name`.
|
||||
- `BadCommunicationError` — wire failure (DLL not loaded, IPC peer dead,
|
||||
etc.).
|
||||
|
||||
### CLI bypass
|
||||
|
||||
`otopcua-focas-cli write` ([`docs/Driver.FOCAS.Cli.md`](../Driver.FOCAS.Cli.md))
|
||||
sets `Writes.Enabled=true` locally for the lifetime of one invocation
|
||||
because the CLI is a per-operator tool — not a long-lived process bound to
|
||||
the central config DB. The server-side flag is untouched; configure-the-
|
||||
server code paths remain safer-by-default.
|
||||
|
||||
Reference in New Issue