fix(s7): worst-severity error message + OCE flushes recorded pass evidence (review round)
This commit is contained in:
@@ -489,6 +489,16 @@ public sealed class S7SpanReadParityTests
|
||||
new S7TagDefinition("BadStr", "DB1.DBB100", S7DataType.String, Writable: false, StringLength: 10),
|
||||
new S7TagDefinition("GoodWord", "DB1.DBW112", S7DataType.UInt16, Writable: false));
|
||||
var factory = new ImageS7PlcFactory(Images());
|
||||
|
||||
// The poison is the FILLER, not a fake knob: Images() writes (i * 37 + 11) & 0xFF, which
|
||||
// steps +37 per byte and so runs ASCENDING except in the ~15% of positions where it wraps
|
||||
// past 256. Byte 100 is not one of those, so the STRING header at 100/101 reads
|
||||
// maxLen 127 / curLen 164 — a current length larger than the capacity, which
|
||||
// S7String.FromByteArray rejects. Asserted rather than assumed, so a change to the filler
|
||||
// pattern fails HERE, loudly, instead of silently turning this into a passing no-op test.
|
||||
var db1Image = factory.Images[(S7NetDataType.DataBlock, 1)];
|
||||
db1Image[101].ShouldBeGreaterThan(
|
||||
db1Image[100], "the S7 STRING at DB1.DBB100 must declare curLen > maxLen to be undecodable");
|
||||
using var driver = new S7Driver(Options(tags, maxGap: 16), "s7-span-decode-fault", factory);
|
||||
await driver.InitializeAsync("{}", ct);
|
||||
|
||||
@@ -555,6 +565,90 @@ public sealed class S7SpanReadParityTests
|
||||
before!.Value, "one tag read fine, so the watchdog's evidence must still advance");
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// The pass's message must explain the state it reports. When a merely-Degraded fault is
|
||||
/// observed BEFORE the access-denied one, escalating to <c>Faulted</c> has to re-point
|
||||
/// <c>LastError</c> at the access-denied cause — reporting the config alert under the
|
||||
/// earlier device-fault message tells the operator to chase the wrong thing.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// This is the reversed ordering of
|
||||
/// <see cref="An_access_denied_tag_keeps_the_pass_Faulted_even_after_a_later_tag_succeeds"/>,
|
||||
/// and the pair is the point: keeping the pass's chronologically-first message satisfies
|
||||
/// that test and fails this one, so only a message that moves WITH the severity passes both.
|
||||
/// </remarks>
|
||||
[Fact]
|
||||
public async Task Escalating_to_Faulted_re_points_the_error_message_at_the_access_denied_cause()
|
||||
{
|
||||
var ct = TestContext.Current.CancellationToken;
|
||||
var factory = new ImageS7PlcFactory(Images());
|
||||
// A: an ordinary device-layer fault (Degraded) FIRST. B: the access-denied config alert
|
||||
// (Faulted) after it. C: no fault at all.
|
||||
factory.PerTagFaults["DB1.DBW0"] = new PlcException(ErrorCode.ReadData, "S7 CPU reported a device fault");
|
||||
factory.PerTagFaults["DB1.DBW2"] = new PlcException(ErrorCode.ReadData, "Accessing object not allowed");
|
||||
using var driver = new S7Driver(Options(NarrowTags(), maxGap: -1), "s7-escalation-message", factory);
|
||||
await driver.InitializeAsync("{}", ct);
|
||||
|
||||
var before = driver.GetHealth().LastSuccessfulRead;
|
||||
var results = await driver.ReadAsync(["A", "B", "C"], ct);
|
||||
|
||||
results[0].StatusCode.ShouldBe(StatusBadDeviceFailure);
|
||||
results[1].StatusCode.ShouldNotBe(0u);
|
||||
results[2].StatusCode.ShouldBe(0u);
|
||||
|
||||
var health = driver.GetHealth();
|
||||
health.State.ShouldBe(DriverState.Faulted, "the access-denied fault must still outrank the earlier one");
|
||||
health.LastError.ShouldNotBeNull();
|
||||
health.LastError!.ShouldContain(
|
||||
"PUT/GET",
|
||||
customMessage: "the message must explain the FAULTED state, not the earlier Degraded one");
|
||||
health.LastSuccessfulRead!.Value.ShouldBeGreaterThan(before!.Value);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Cancellation mid-pass abandons the batch but must NOT discard the evidence the pass had
|
||||
/// already gathered: a tag that read successfully before the cancellation still advances
|
||||
/// <c>LastSuccessfulRead</c>.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// Deciding health once at the end of the pass makes this a real risk, which per-item
|
||||
/// writes did not have. On a partially-working device a repeatedly-cancelled poll would
|
||||
/// freeze <c>LastSuccessfulRead</c> while tags were demonstrably still being read, and the
|
||||
/// comms-loss watchdog — which trips on non-Healthy state AND a frozen timestamp — would
|
||||
/// reconnect a CPU that is answering. Flushing from a <c>finally</c> is what prevents it.
|
||||
/// </remarks>
|
||||
[Fact]
|
||||
public async Task A_cancelled_pass_still_flushes_the_evidence_it_had_already_gathered()
|
||||
{
|
||||
var ct = TestContext.Current.CancellationToken;
|
||||
// Narrow first (a per-address read, which the hang knob does NOT intercept), then a wide
|
||||
// Int64 (a BLOCK read, which it does) — so the pass banks one success and is then cancelled
|
||||
// mid-flight on the very next tag.
|
||||
var tags = S7RawTags.Entries(
|
||||
new S7TagDefinition("Narrow", "DB1.DBW0", S7DataType.UInt16, Writable: false),
|
||||
new S7TagDefinition("Wide", "DB1.DBB8", S7DataType.Int64, Writable: false));
|
||||
var factory = new ImageS7PlcFactory(Images()) { HangReadBytes = true };
|
||||
// maxGap -1 keeps both tags on the per-tag path, in reference order.
|
||||
using var driver = new S7Driver(Options(tags, maxGap: -1), "s7-cancel-flush", factory);
|
||||
await driver.InitializeAsync("{}", ct);
|
||||
|
||||
var before = driver.GetHealth().LastSuccessfulRead;
|
||||
|
||||
using var cts = new CancellationTokenSource();
|
||||
var reading = driver.ReadAsync(["Narrow", "Wide"], cts.Token);
|
||||
await factory.ReadBytesEntered.Task.WaitAsync(TimeSpan.FromSeconds(10), ct);
|
||||
await cts.CancelAsync();
|
||||
|
||||
await Should.ThrowAsync<OperationCanceledException>(async () => await reading);
|
||||
|
||||
// The first tag really was served before the cancellation — one per-address read happened.
|
||||
factory.StringReadCalls.ShouldBe(1);
|
||||
|
||||
var health = driver.GetHealth();
|
||||
health.LastSuccessfulRead!.Value.ShouldBeGreaterThan(
|
||||
before!.Value, "the banked success must survive the abandoned batch");
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// A pass that observes NOTHING — every reference unresolvable, so not one tag was read and
|
||||
/// not one failed — reports nothing: it must leave the driver's prior <c>Faulted</c> config
|
||||
|
||||
Reference in New Issue
Block a user