feat(deploy): wire the four G-7 inspectors into the deploy-time TagConfig gate

Adds the Sql / MTConnect / Calculation / OpcUaClient Contracts ProjectReferences to
ControlPlane and their entries to EquipmentTagConfigInspector, closing the G-7 asymmetry: the
deploy gate now checks every driver the AdminUI checks. Galaxy is the sole remaining unmapped
type and is so by design — its dotted tag_name.AttributeName reference has no typed shape, and
the AdminUI has no typed editor for it either, so the two gates agree.

Adding the ProjectReference is what makes EquipmentTagConfigInspectorCoverageTests demand a map
entry (its sweep scans the output directory, so an unreferenced Contracts assembly is invisible
to it). Falsified: deleting the Sql entry fails
Every_driver_shipping_an_Inspect_is_wired_into_the_dispatch_map with
["SqlTagDefinitionFactory"]; restored.

Tests: three cases per driver in EquipmentTagConfigInspectorTests (canonical valid config warns
nothing / present-but-invalid field draws a warning naming it / broken JSON warns without
throwing), plus a Calculation control pinning that the two shapes the runtime accepts and the
editor refuses draw nothing. OpcUaClient moved out of the unmapped-driver theory.

New TagConfigAuthoringDeployParityTests (in AdminUI.Tests, the only suite that sees both gates)
pins the direction that matters: a config the AdminUI model's own ToJson produces and Validate
accepts draws no deploy warning. Its falsifiability control — the same driver types warning
about a blob the editor refuses — caught a pre-existing, unrelated authoring-side gap:
MTConnectTagConfigModel reads dataType leniently, so a misspelled name loads as String and
saves clean while the strict runtime rejects it. Left alone (rewriting the editors is out of
scope); the control uses the digits-only shape both gates refuse, and the case is documented
inline.
This commit is contained in:
Joseph Doherty
2026-08-09 21:14:49 -04:00
parent 2947a2b9e2
commit 1469fbb4d1
5 changed files with 348 additions and 12 deletions
@@ -50,6 +50,18 @@
<ProjectReference Include="..\..\Drivers\ZB.MOM.WW.OtOpcUa.Driver.TwinCAT.Contracts\ZB.MOM.WW.OtOpcUa.Driver.TwinCAT.Contracts.csproj"/>
<ProjectReference Include="..\..\Drivers\ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Contracts\ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Contracts.csproj"/>
<ProjectReference Include="..\..\Drivers\ZB.MOM.WW.OtOpcUa.Driver.Mqtt.Contracts\ZB.MOM.WW.OtOpcUa.Driver.Mqtt.Contracts.csproj"/>
<!-- G-7: the four drivers the deploy gate used to be blind to, while the AdminUI's
TagConfigValidator checked them. Adding the reference is what makes
EquipmentTagConfigInspectorCoverageTests demand a dispatch-map entry for them — the guard scans
the output directory, so an unreferenced Contracts assembly is invisible to it.
Note OpcUaClient.Contracts brings OPCFoundation.NetStandard.Opc.Ua.Client transitively: its
NamespaceMap re-binds a stable nsu= reference against a live session. Every host that loads
ControlPlane (Host, AdminUI) already carries the OPC UA stack, so this adds no new deployment
surface. -->
<ProjectReference Include="..\..\Drivers\ZB.MOM.WW.OtOpcUa.Driver.Sql.Contracts\ZB.MOM.WW.OtOpcUa.Driver.Sql.Contracts.csproj"/>
<ProjectReference Include="..\..\Drivers\ZB.MOM.WW.OtOpcUa.Driver.MTConnect.Contracts\ZB.MOM.WW.OtOpcUa.Driver.MTConnect.Contracts.csproj"/>
<ProjectReference Include="..\..\Drivers\ZB.MOM.WW.OtOpcUa.Driver.Calculation.Contracts\ZB.MOM.WW.OtOpcUa.Driver.Calculation.Contracts.csproj"/>
<ProjectReference Include="..\..\Drivers\ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient.Contracts\ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient.Contracts.csproj"/>
</ItemGroup>
</Project>