refactor(configdb): drop GenerationId FK from live-edit entities

Phase 1b of the v2 entity-model rewrite. The design's live-edit model means
the 12 v2 live-edit entities no longer carry a generation scope — they're
edited directly via AdminOperationsActor, with RowVersion (added in Task 14a)
providing last-write-wins detection.

Entity changes (12 files):

  Equipment, DriverInstance, Device, Tag, PollGroup, Namespace,
  UnsArea, UnsLine, NodeAcl, Script, VirtualTag, ScriptedAlarm

  - Removed: public long GenerationId
  - Removed: public ConfigGeneration? Generation (navigation)

DbContext changes (OtOpcUaConfigDbContext.cs):

  - Removed 12 HasOne(x => x.Generation).WithMany().HasForeignKey... mappings
  - Rewrote ~36 indexes: dropped the GenerationId column from each composite
    key, renamed UX_<Table>_Generation_<X> -> UX_<Table>_<X> and
    IX_<Table>_Generation_<X> -> IX_<Table>_<X>. Logical IDs become globally
    unique (UX_<Table>_LogicalId on the LogicalId column alone).
  - Removed Namespace's redundant UX_Namespace_Generation_LogicalId_Cluster
    index (subsumed by the new UX_Namespace_LogicalId).

Core.Tests fixtures (4 files):

  Removed "GenerationId = 1," lines from:
    - PermissionTrieBuilderTests.cs (NodeAcl Row factory)
    - PermissionTrieTests.cs (NodeAcl Row factory)
    - TriePermissionEvaluatorTests.cs (NodeAcl Row factory + 2 gen{1,5}Row
      mutations that test stale-generation evaluation; the trie itself still
      carries a generation tag via PermissionTrie.GenerationId, fed in via
      PermissionTrieBuilder.Build's generationId parameter, so the tests
      still exercise the production code path)
    - EquipmentNodeWalkerTests.cs (Area/Line/Eq/Tag/VirtualTag/ScriptedAlarm
      builders)

Expected breakage (accepted per Task 56 policy):

  src/Server/ZB.MOM.WW.OtOpcUa.Server   ~25 errors  (DriverInstanceBootstrapper,
                                                     AuthorizationBootstrap,
                                                     EquipmentNamespaceContentLoader,
                                                     Phase7Composer, ...)
  src/Server/ZB.MOM.WW.OtOpcUa.Admin    ~45 errors  (VirtualTags.razor,
                                                     ScriptedAlarms.razor,
                                                     DriverInstanceService,
                                                     EquipmentService,
                                                     EquipmentImportBatchService,
                                                     UnsService,
                                                     FocasDriverDetailService,
                                                     ...)

Server.Tests, Admin.Tests, Admin.E2ETests also break transitively (they
project-reference Server/Admin). All deleted in Task 56.

Verification:
  dotnet build src/Core/ZB.MOM.WW.OtOpcUa.Configuration -> 0 errors
  dotnet build tests/Core/ZB.MOM.WW.OtOpcUa.Core.Tests  -> 0 errors
  dotnet build tests/Core/ZB.MOM.WW.OtOpcUa.Configuration.Tests -> 0 errors
  dotnet build (whole solution) -> 70 errors, all in Server/Admin
This commit is contained in:
Joseph Doherty
2026-05-26 04:06:25 -04:00
parent 4bb4ad8acb
commit 13d3aeab09
17 changed files with 63 additions and 137 deletions

View File

@@ -153,7 +153,7 @@ public sealed class EquipmentNodeWalkerTests
var eq = Eq("eq-1", "line-1", "oven-3");
var vtag = new VirtualTag
{
VirtualTagRowId = Guid.NewGuid(), GenerationId = 1,
VirtualTagRowId = Guid.NewGuid(),
VirtualTagId = "vt-1", EquipmentId = "eq-1", Name = "LineRate",
DataType = "Float32", ScriptId = "scr-1", Historize = true,
};
@@ -179,7 +179,7 @@ public sealed class EquipmentNodeWalkerTests
var eq = Eq("eq-1", "line-1", "oven-3");
var alarm = new ScriptedAlarm
{
ScriptedAlarmRowId = Guid.NewGuid(), GenerationId = 1,
ScriptedAlarmRowId = Guid.NewGuid(),
ScriptedAlarmId = "al-1", EquipmentId = "eq-1", Name = "HighTemp",
AlarmType = "LimitAlarm", MessageTemplate = "{Temp} exceeded",
PredicateScriptId = "scr-9", Severity = 800,
@@ -205,13 +205,13 @@ public sealed class EquipmentNodeWalkerTests
var eq = Eq("eq-1", "line-1", "oven-3");
var vtag = new VirtualTag
{
VirtualTagRowId = Guid.NewGuid(), GenerationId = 1,
VirtualTagRowId = Guid.NewGuid(),
VirtualTagId = "vt-1", EquipmentId = "eq-1", Name = "Disabled",
DataType = "Float32", ScriptId = "scr-1", Enabled = false,
};
var alarm = new ScriptedAlarm
{
ScriptedAlarmRowId = Guid.NewGuid(), GenerationId = 1,
ScriptedAlarmRowId = Guid.NewGuid(),
ScriptedAlarmId = "al-1", EquipmentId = "eq-1", Name = "DisabledAlarm",
AlarmType = "LimitAlarm", MessageTemplate = "x",
PredicateScriptId = "scr-9", Enabled = false,
@@ -313,18 +313,17 @@ public sealed class EquipmentNodeWalkerTests
private static UnsArea Area(string id, string name) => new()
{
UnsAreaId = id, ClusterId = "c1", Name = name, GenerationId = 1,
UnsAreaId = id, ClusterId = "c1", Name = name,
};
private static UnsLine Line(string id, string areaId, string name) => new()
{
UnsLineId = id, UnsAreaId = areaId, Name = name, GenerationId = 1,
UnsLineId = id, UnsAreaId = areaId, Name = name,
};
private static Equipment Eq(string equipmentId, string lineId, string name) => new()
{
EquipmentRowId = Guid.NewGuid(),
GenerationId = 1,
EquipmentId = equipmentId,
EquipmentUuid = Guid.NewGuid(),
DriverInstanceId = "drv",
@@ -337,7 +336,6 @@ public sealed class EquipmentNodeWalkerTests
string? equipmentId, string? tagConfig = null) => new()
{
TagRowId = Guid.NewGuid(),
GenerationId = 1,
TagId = tagId,
DriverInstanceId = "drv",
EquipmentId = equipmentId,