refactor(opcua): delete the dead v3 equipment-tag materialisation (B5)

Review 01 U2. The composer never emits EquipmentTags in v3 (device values
live in the Raw subtree and reach equipment as UnsReferenceVariables), so
the equipment-tag plan diff sets (Added/Removed/ChangedEquipmentTags,
EquipmentTagDelta), the planner's diff over them, the classifier's
TagDeltaIsSurgicalEligible and its Rebuild clause, the applier's
MaterialiseEquipmentTags pass, surgical ChangedEquipmentTags loop,
removed-tag teardown loop and add-announcement term, and the publish
actor's equipment-tag pass were unreachable, maintained dead weight.
IsEmpty keeps its semantics (an otherwise-empty plan is still Empty).

Kept, deliberately: AddressSpaceComposition.EquipmentTags and the
EquipmentTagPlan record — Runtime's DeploymentArtifact (outside this
lane) still assigns the empty set and the artifact parity tests assert
it; follow-up F2 removes both together.

Tests: the equipment-tag vehicle tests for PureRemove / AddRemoveMix /
the rebuild ratchet are re-expressed over raw tags (same applier paths);
the equipment-tag surgical and classifier tests are deleted (their raw /
UNS-reference equivalents already exist); SubscriptionSurvivalTests now
materialises its tags through MaterialiseRawSubtree.

Refs #732

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
This commit is contained in:
Joseph Doherty
2026-10-22 10:29:54 -04:00
parent 1578efd4a9
commit 118933d5d5
10 changed files with 159 additions and 1139 deletions
@@ -725,8 +725,8 @@ public sealed class OpcUaPublishActor : ReceiveActor, IWithTimers
}
/// <summary>
/// Run the five node-materialising applier passes — Raw subtree, UNS references, scripted alarms,
/// equipment tags, equipment VirtualTags — either over the FULL composition (after a rebuild) or over
/// Run the four node-materialising applier passes — Raw subtree, UNS references, scripted alarms,
/// equipment VirtualTags — either over the FULL composition (after a rebuild) or over
/// just this plan's delta (surgical deploys). <c>MaterialiseHierarchy</c> is NOT one of them:
/// the caller always runs it in full, because parents must exist before any add.
/// </summary>
@@ -809,21 +809,7 @@ public sealed class OpcUaPublishActor : ReceiveActor, IWithTimers
if (addedAlarms.Count > 0) failedNodes += applier.MaterialiseScriptedAlarms(composition, addedAlarms);
}
// Equipment-namespace tags get their own pass: ensures each signal's Variable (and any
// FolderPath sub-folder) exists under its already-materialised equipment folder so
// clients can browse them. Live values are pushed by DriverHostActor.ForwardBatchToMux after
// each subscription cycle; variables show BadWaitingForInitialData only until the first
// publish interval fires.
if (fullComposition)
{
failedNodes += applier.MaterialiseEquipmentTags(composition);
}
else if (plan.AddedEquipmentTags.Count > 0)
{
failedNodes += applier.MaterialiseEquipmentTags(composition, plan.AddedEquipmentTags);
}
// Equipment-namespace VirtualTags get their own pass right after the equipment tags:
// Equipment-namespace VirtualTags get their own pass right after the scripted alarms:
// ensures each computed signal's Variable (and any FolderPath sub-folder) exists under its
// equipment folder with a folder-scoped NodeId. VirtualTagHostActor.OnResult pushes live
// values once the first dependency update arrives; until then variables show BadWaitingForInitialData.