fix(historian): preserve stable alarm delivery identities
This commit is contained in:
@@ -153,6 +153,19 @@ Ordering follows from that: the drain reads in `enqueued_at_utc` order (with `id
|
||||
as a tiebreak so the ordering is total), because a hashed key carries no
|
||||
insertion sequence.
|
||||
|
||||
Gateway delivery carries a separate nonzero `DeliveryId` GUID. Direct event instances
|
||||
create it once; retries and record copies preserve it. It is excluded from queue JSON
|
||||
and business equality, so the existing payload fingerprint and pair deduplication stay
|
||||
unchanged. The drain derives its delivery GUID solely from the persisted row `id`,
|
||||
including migrated legacy rows. It never hashes a reconstructed payload or mints an ID
|
||||
per send. The versioned encoding in `AlarmDeliveryIds` therefore survives retry,
|
||||
restart, payload edits and replicated failover without a schema migration.
|
||||
|
||||
Different business payloads at the same timestamp remain distinct; completely identical
|
||||
payloads deliberately converge. An explicitly empty direct delivery ID is rejected.
|
||||
The Gateway mapper sends this GUID as the wire event ID; the live alarm readback test
|
||||
requires that exact ID. SQL Server and QuestDB retain their existing event-ID schemes.
|
||||
|
||||
`EnqueueAsync` does a single `INSERT … ON CONFLICT DO NOTHING` on the hot path.
|
||||
To avoid a `SELECT COUNT(*)` on every enqueue, the sink keeps an in-memory
|
||||
non-dead-lettered row counter (seeded at startup, kept current by every mutation,
|
||||
|
||||
Reference in New Issue