diff --git a/docs/plans/2026-06-06-equipment-namespace-materialization-scope.md b/docs/plans/2026-06-06-equipment-namespace-materialization-scope.md
new file mode 100644
index 00000000..1ae31d59
--- /dev/null
+++ b/docs/plans/2026-06-06-equipment-namespace-materialization-scope.md
@@ -0,0 +1,201 @@
+# Scope: Equipment-Namespace Materialization in the Live Deploy Path
+
+**Status:** Scoping (not yet a task plan)
+**Date:** 2026-06-06
+**Author:** investigation while building the Northwind UNS overlay (see `scadaproj/otopcua-uns-loader/`)
+**Depends on:** the driver value-streaming fixes already on `master` (`c1ce583`, `b1b3f3f`)
+
+---
+
+## 1. One-paragraph summary
+
+OtOpcUa can build a **SystemPlatform** namespace (the Galaxy mirror) into the live OPC UA
+address space with streaming values, but it **cannot do the same for an `Equipment`-kind
+namespace**. The canonical UNS (`Enterprise/Site/Area/Line/Equipment/Signal`) that an Equipment
+namespace represents only ever materialises its **skeleton** (Area/Line/Equipment *folders*); the
+**signals under equipment** (`Tag`, `VirtualTag`, `ScriptedAlarm` rows) never appear, because the
+component that turns those rows into OPC UA variables — `EquipmentNodeWalker` — is **fully built
+and unit-tested but never invoked in production**, and the live rebuild path doesn't carry the
+data it needs. This document scopes the work to finish that pipeline.
+
+---
+
+## 2. What works vs. what doesn't (verified 2026-06-06)
+
+**Works — SystemPlatform / Galaxy mirror (reference implementation):**
+A deploy materialises one folder per Galaxy object and one variable per `Tag` row, and the driver
+streams live values into them. Verified live: 396 tags across 40 machines, all `Good`, on
+`opc.tcp://localhost:4840`. Path:
+`OpcUaPublishActor.HandleRebuild` → `Phase7Applier.MaterialiseHierarchy` +
+`Phase7Applier.MaterialiseGalaxyTags`, and values via the `DriverHostActor` SubscribeBulk pass
+(`b1b3f3f`).
+
+**Doesn't work — Equipment namespace:**
+Deploying an `Equipment` namespace + a `UnsArea`/`UnsLine`/`Equipment` + one `VirtualTag` produced:
+
+```
+Phase7Applier: hierarchy materialised (areas=1, lines=1, equipment=1) ← folders only
+```
+
+…and the equipment node had **zero child variables** — the VirtualTag never materialised. There
+was no equipment-tag/virtual-tag log line at all.
+
+---
+
+## 3. Root cause (precise)
+
+Three gaps, in order of how fundamental they are:
+
+### 3.1 `EquipmentNodeWalker` is built + tested but never wired (the core gap)
+
+- `src/Core/ZB.MOM.WW.OtOpcUa.Core/OpcUa/EquipmentNodeWalker.cs` — `Walk(IAddressSpaceBuilder, EquipmentNamespaceContent)`
+ materialises every `Equipment` row as a folder and every Equipment-bound `Tag` / `VirtualTag` /
+ `ScriptedAlarm` as a variable (NodeId = `DriverAttributeInfo.FullName`, i.e. the tag's
+ `TagConfig.FullName`; VirtualTag uses its `VirtualTagId`).
+- **The only call sites are in `tests/Core/.../EquipmentNodeWalkerTests.cs`.** Nothing in `src`
+ ever calls `EquipmentNodeWalker.Walk`, and nothing builds its input record
+ `EquipmentNamespaceContent` (the record exists; no producer exists).
+- The live rebuild — `src/Server/.../Runtime/OpcUa/OpcUaPublishActor.cs:HandleRebuild` — calls
+ `MaterialiseHierarchy` (the Area/Line/Equipment *folders*) and `MaterialiseGalaxyTags`
+ (SystemPlatform only). It never calls `EquipmentNodeWalker`.
+- `OtOpcUaNodeManager` references `EquipmentNodeWalker` only in a header comment — not in
+ `CreateAddressSpace`.
+
+### 3.2 The deployment composition/artifact drops equipment signals
+
+- `Phase7CompositionResult` (`src/Server/.../OpcUaServer/Phase7Composer.cs`) carries
+ `UnsAreas`, `UnsLines`, `EquipmentNodes` *(EquipmentId, DisplayName, UnsLineId — no tags)*,
+ `DriverInstancePlans`, `ScriptedAlarmPlans`, `GalaxyTags`. **There is no equipment-tag or
+ virtual-tag list.**
+- `DeploymentArtifact.ParseComposition` (`src/Server/.../Runtime/Drivers/DeploymentArtifact.cs`)
+ reads the artifact's `Tags` array but **`BuildGalaxyTagPlans` explicitly skips any tag with a
+ non-null `EquipmentId`** (line ~176). So even though equipment tags are serialised into the
+ artifact, the composition the node consumes throws them away.
+
+So even if `EquipmentNodeWalker` were wired into `HandleRebuild`, it would have no equipment-tag
+data to walk.
+
+### 3.3 No value source for Equipment-namespace signals
+
+Equipment signals can be valued two ways; **neither is currently wired**:
+
+- **Driver-sourced `Tag` (e.g. an OPC UA Client remap of the Galaxy mirror):** the **OpcUaClient
+ driver has no factory registration** — `DriverFactoryBootstrap.Register`
+ (`src/Server/.../Host/Drivers/DriverFactoryBootstrap.cs`) wires AbCip/AbLegacy/FOCAS/Galaxy/
+ Modbus/S7/TwinCAT but **not OpcUaClient**, so an `OpcUaClient` `DriverInstance` silently stubs →
+ no values. (The driver itself, `IDriver,ITagDiscovery,IReadable,IWritable,ISubscribable,…`,
+ exists and is otherwise complete; only the factory `Register` is missing.)
+- **`VirtualTag` (script mirrors a live tag):** the `DependencyMuxActor` + a real
+ `IVirtualTagEvaluator` are registered (`Runtime/ServiceCollectionExtensions.cs:100`,
+ `Host/Program.cs:102`), and driver values now reach the mux (`DriverHostActor.ForwardToMux`,
+ `b1b3f3f`). But `VirtualTagContext.GetTag` reads from a per-evaluation cache fed by an
+ `ITagUpstreamSource`, and **no concrete `ITagUpstreamSource` is registered in the Host** — and
+ it is unverified whether a `VirtualTag` in an `Equipment` namespace can resolve a tag that lives
+ in the `SystemPlatform` namespace (cross-namespace `ctx.GetTag("/TestMachine_001/…")`).
+
+---
+
+## 4. Goal / acceptance criteria
+
+A deploy that includes an `Equipment`-kind namespace results in, on `opc.tcp://…:4840`:
+
+1. **Structure:** browsable `…////` for every `UnsArea`/`UnsLine`/
+ `Equipment`/`Tag`(+`VirtualTag`,`ScriptedAlarm`) row — folders **browse-named by their friendly
+ `Name`**, not their logical Id (see §6.4).
+2. **Values:** each signal carries a live `Good` value (driver-sourced and/or VirtualTag-derived).
+3. **Reload-safe:** survives a node restart with no re-deploy (must run on the `RestoreApplied`
+ bootstrap path added in `b1b3f3f`, not just on a fresh apply).
+4. **Verifiable headlessly:** the `scadaproj/otopcua-uns-loader` tool's `verify` passes against the
+ company-shape namespace (extend it to browse the Equipment tree).
+
+---
+
+## 5. Workstreams
+
+### WS-1 — Carry equipment signals through the composition (foundational)
+Extend `Phase7CompositionResult` with equipment `Tag`/`VirtualTag`/`ScriptedAlarm` plans (or reuse
+`EquipmentNamespaceContent`), populate them in `Phase7Composer.Compose`, serialise them in the
+deployment artifact, and parse them in `DeploymentArtifact.ParseComposition` (stop discarding
+`EquipmentId != null` tags). **Risk: medium** (touches composer + artifact format + planner; needs
+a format-compat story for already-sealed artifacts). **Effort: ~1–2 days.**
+
+### WS-2 — Materialise equipment signals in the live rebuild (wire the existing component)
+In `OpcUaPublishActor.HandleRebuild`, after `MaterialiseHierarchy`, build `EquipmentNamespaceContent`
+from the composition and call the already-tested `EquipmentNodeWalker.Walk`. Make it idempotent and
+diff-aware to match the existing Galaxy-tag pass. **Risk: low–medium** (component is tested; this is
+wiring + an idempotency pass). **Effort: ~0.5–1 day.**
+
+### WS-3 — Value path (pick one or both; see §6.1)
+- **3a VirtualTag route:** register a concrete `ITagUpstreamSource` in the Host that bridges the
+ `DependencyMuxActor`'s tag values into the VirtualTag read-cache; confirm/enable cross-namespace
+ `ctx.GetTag` resolution (Equipment VirtualTag reading a SystemPlatform mirror tag) and the
+ dependency-graph re-evaluation trigger. **Risk: high** (cross-namespace resolution + dependency
+ tracking are unproven end-to-end). **Effort: ~2–3 days.**
+- **3b OpcUaClient route:** write+register `OpcUaClientDriverFactoryExtensions.Register` and add it
+ to `DriverFactoryBootstrap.Register`; extend the SubscribeBulk pass to also subscribe
+ Equipment-namespace `Tag` refs (`TagConfig.FullName`; NodeId == FullName, so the existing
+ `ForwardToMux` value routing already applies — a ~30-line generalisation prototyped and reverted
+ this session); decide the self-referential endpoint topology (a MAIN driver node OPC-UA-clienting
+ into its own `:4840` Galaxy mirror, vs a second cluster). **Risk: high** (unfinished driver +
+ self-loop topology). **Effort: ~2–4 days.**
+
+### WS-4 — Browse-name fix (cosmetic but required for a usable shape)
+Today the UNS folder browse name is the logical **Id** (observed `nw-area-filling`), not the
+friendly `Name` (`filling`). Confirm whether `Phase7Applier.MaterialiseHierarchy` /
+`EquipmentNode.DisplayName` should use `UnsArea.Name`/`UnsLine.Name`/`Equipment.Name` for the
+BrowseName (keeping the Id as the NodeId). **Risk: low.** **Effort: ~0.5 day.**
+
+### WS-5 — Tests + headless verification
+Unit: composer carries equipment signals; `HandleRebuild` materialises them; round-trip artifact
+parse. Integration: a docker-dev deploy of a small Equipment namespace browses + reads `Good`.
+Extend `otopcua-uns-loader verify` to assert the Equipment tree. **Effort: ~1 day.**
+
+---
+
+## 6. Design decisions / open questions
+
+1. **VirtualTag (3a) vs OpcUaClient (3b) for live values.** VirtualTags reuse the live Galaxy
+ mirror in-process (no second OPC UA session) but lean on unproven cross-namespace script
+ resolution; OpcUaClient is the documented "remote-equipment → UNS" pattern but needs an
+ unfinished driver factory and a self-referential session. **Recommendation:** prototype 3a first
+ (smaller surface, no new driver), fall back to 3b if cross-namespace resolution proves
+ intractable. A structure-only milestone (WS-1/2/4, no values) is independently shippable.
+2. **Cross-namespace `ctx.GetTag`.** Does an Equipment-namespace VirtualTag resolve a
+ SystemPlatform Galaxy tag by browse path (`/TestMachine_001/TestChangingInt`) or by reference
+ (`TestMachine_001.TestChangingInt`)? Determines the script-authoring contract. Must be settled
+ before WS-3a.
+3. **Artifact format compatibility.** Adding equipment signals to the artifact changes its shape;
+ ensure older sealed artifacts still parse (the parser is tolerant today — keep it so).
+4. **Browse-name source** (WS-4) — `Name` vs `Id`. Picking `Name` makes the company shape readable;
+ confirm nothing keys off the Id-as-BrowseName.
+
+---
+
+## 7. Recommended sequencing
+
+1. **WS-1 + WS-2 + WS-4 (structure-only):** Equipment namespaces browse the real
+ `…/area/line/equipment/signal` shape with `BadWaitingForInitialData` leaves. Independently
+ shippable; de-risks the composition/materialisation half.
+2. **WS-3a (VirtualTag values):** lights the structure up by mirroring the live Galaxy tags.
+3. **WS-3b (OpcUaClient driver):** only if a true remote-equipment driver path is wanted beyond the
+ Galaxy mirror.
+4. **WS-5** throughout.
+
+**Rough total:** structure-only ≈ 2–3.5 days; +VirtualTag values ≈ +2–3 days.
+
+## 8. Out of scope
+- Authoring the company UNS rows (the `scadaproj/otopcua-uns-loader` tool already generates them
+ from `company-uns.json`).
+- Any change to the SystemPlatform/Galaxy path, which works.
+- The AdminUI UNS editor.
+
+## 9. Key references
+- Works (reference): `OpcUaPublishActor.HandleRebuild` + `Phase7Applier.MaterialiseGalaxyTags`;
+ SubscribeBulk in `DriverHostActor` (commits `c1ce583`, `b1b3f3f`).
+- Built-but-unwired: `Core/OpcUa/EquipmentNodeWalker.cs` (+ `EquipmentNamespaceContent`),
+ tested only by `EquipmentNodeWalkerTests.cs`.
+- Composition gap: `OpcUaServer/Phase7Composer.cs` (`Phase7CompositionResult`),
+ `Runtime/Drivers/DeploymentArtifact.cs` (`BuildGalaxyTagPlans` skips `EquipmentId != null`).
+- Value gaps: `Host/Drivers/DriverFactoryBootstrap.cs` (no OpcUaClient registration);
+ `Core.VirtualTags/ITagUpstreamSource.cs` (no Host registration found).
+- The consuming tool + the company model: `scadaproj/otopcua-uns-loader/`, `scadaproj/company-uns.json`.