fix(focas): a returned status never ends a device's batch; round-2 minors (#740 review round 2)
N1: linkDown is set only when NO reply arrived, i.e. a timeout, a transport exception or a connect failure. A status the CNC returned proves it answered. EW_REJECT and every unlisted rc map to BadCommunicationError, so a deterministic rc on one tag used to fail every later tag of a reachable control on every poll. The comms-classed status still degrades health. The coalescer already treated a returned refusal this way; it is unchanged. Tests: a returned EW_REJECT on tag 1 leaves tags 2 and 3 read and Good (red before). A timeout still fails the rest without reading them (positive control). Minors: - m1: the _lifecycleLock doc now covers the health transitions it also guards. - m2: the NoteFixedTreeFailed summary says a refusal credits the answer. - m3: ReadAsync stamps a failed batch's exception with the generation the batch started under, and HandlePollError degrades that generation only. - m4: the fixed-tree "blip" absence check runs unconditionally under a wide budget, and asserts that both ticks landed inside it. - m5: direct unit cases for the coalescer link-down paths. A transport fault on the first range fails the second range and the per-tag tag without reading them. A connect failure costs one connect per batch. CncRelay.Up() retries the re-bind. Refs #740 Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
This commit is contained in:
@@ -18,6 +18,7 @@ public sealed class FocasFixedTreeHealthTests
|
||||
{
|
||||
private const string Host = "focas://10.0.0.5:8193";
|
||||
private static readonly TimeSpan Stale = TimeSpan.FromMilliseconds(300);
|
||||
private static readonly TimeSpan BlipBudget = TimeSpan.FromMilliseconds(1500);
|
||||
|
||||
/// <summary>A CNC that can be switched off (transport failure) or made to refuse the dynamic read.</summary>
|
||||
private sealed class CncSwitch
|
||||
@@ -58,7 +59,7 @@ public sealed class FocasFixedTreeHealthTests
|
||||
}
|
||||
}
|
||||
|
||||
private static FocasDriver FixedOnlyDriver(CncSwitch sw) => new(new FocasDriverOptions
|
||||
private static FocasDriver FixedOnlyDriver(CncSwitch sw, TimeSpan? budget = null) => new(new FocasDriverOptions
|
||||
{
|
||||
Devices = [new FocasDeviceOptions(Host)],
|
||||
RawTags = [FocasRawTags.Entry(new FocasTagDefinition("raw/X", Host, "FIXED:Axes/X/AbsolutePosition", FocasDataType.Float64))],
|
||||
@@ -71,7 +72,7 @@ public sealed class FocasFixedTreeHealthTests
|
||||
},
|
||||
}, "focas-fixed-health", new FakeFocasClientFactory { Customise = () => new SwitchableCnc(sw) })
|
||||
{
|
||||
FixedTreeStaleBudgetOverride = Stale,
|
||||
FixedTreeStaleBudgetOverride = budget ?? Stale,
|
||||
};
|
||||
|
||||
/// <summary>
|
||||
@@ -83,7 +84,9 @@ public sealed class FocasFixedTreeHealthTests
|
||||
public async Task Fixed_only_driver_degrades_when_its_cnc_disappears_and_recovers_when_it_returns()
|
||||
{
|
||||
var sw = new CncSwitch();
|
||||
await using var drv = FixedOnlyDriver(sw);
|
||||
// A wide budget (review round 2 m4): two 20 ms ticks always land well inside it, so the "blip does not
|
||||
// degrade" absence check below runs unconditionally instead of being skipped on a slow agent.
|
||||
await using var drv = FixedOnlyDriver(sw, BlipBudget);
|
||||
await drv.InitializeAsync("{}", CancellationToken.None);
|
||||
await WaitUntil(() => drv.GetDeviceState(Host)?.LastFixedPollUtc is not null);
|
||||
|
||||
@@ -96,9 +99,9 @@ public sealed class FocasFixedTreeHealthTests
|
||||
var lastAnswer = drv.GetDeviceState(Host)!.LastFixedPollUtc!.Value;
|
||||
// Two failed ticks have demonstrably happened (positive evidence for the absence check below) …
|
||||
await WaitUntil(() => Volatile.Read(ref sw.Failures) >= 2);
|
||||
// … and, if they landed inside the budget, the driver is still Healthy.
|
||||
if (DateTime.UtcNow - lastAnswer < Stale)
|
||||
drv.GetHealth().State.ShouldBe(DriverState.Healthy, "a blip inside the staleness budget does not degrade");
|
||||
// … inside the budget (asserted, not assumed), and the driver is still Healthy.
|
||||
(DateTime.UtcNow - lastAnswer).ShouldBeLessThan(BlipBudget, "the two failed ticks must land inside the budget");
|
||||
drv.GetHealth().State.ShouldBe(DriverState.Healthy, "a blip inside the staleness budget does not degrade");
|
||||
await WaitUntil(() => drv.GetHealth().State == DriverState.Degraded);
|
||||
var frozen = drv.GetHealth().LastSuccessfulRead;
|
||||
var failuresAtDegrade = Volatile.Read(ref sw.Failures);
|
||||
|
||||
Reference in New Issue