fix(focas): a returned status never ends a device's batch; round-2 minors (#740 review round 2)
N1: linkDown is set only when NO reply arrived, i.e. a timeout, a transport exception or a connect failure. A status the CNC returned proves it answered. EW_REJECT and every unlisted rc map to BadCommunicationError, so a deterministic rc on one tag used to fail every later tag of a reachable control on every poll. The comms-classed status still degrades health. The coalescer already treated a returned refusal this way; it is unchanged. Tests: a returned EW_REJECT on tag 1 leaves tags 2 and 3 read and Good (red before). A timeout still fails the rest without reading them (positive control). Minors: - m1: the _lifecycleLock doc now covers the health transitions it also guards. - m2: the NoteFixedTreeFailed summary says a refusal credits the answer. - m3: ReadAsync stamps a failed batch's exception with the generation the batch started under, and HandlePollError degrades that generation only. - m4: the fixed-tree "blip" absence check runs unconditionally under a wide budget, and asserts that both ticks landed inside it. - m5: direct unit cases for the coalescer link-down paths. A transport fault on the first range fails the second range and the per-tag tag without reading them. A connect failure costs one connect per batch. CncRelay.Up() retries the re-bind. Refs #740 Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
This commit is contained in:
@@ -153,6 +153,108 @@ public sealed class FocasConcurrentDeviceReadTests
|
||||
await drv.ShutdownAsync(CancellationToken.None);
|
||||
}
|
||||
|
||||
/// <summary>Counts per-tag reads; one address can be made to time out (throw) or answer a status.</summary>
|
||||
private sealed class CountingClient : FakeFocasClient
|
||||
{
|
||||
public int Reads;
|
||||
public string? TimeoutAt;
|
||||
|
||||
public override async Task<(object? value, uint status)> ReadAsync(
|
||||
FocasAddress address, FocasDataType type, CancellationToken ct)
|
||||
{
|
||||
Interlocked.Increment(ref Reads);
|
||||
if (address.Canonical == TimeoutAt)
|
||||
{
|
||||
await Task.Delay(Timeout.Infinite, ct).ConfigureAwait(false);
|
||||
}
|
||||
return await base.ReadAsync(address, type, ct).ConfigureAwait(false);
|
||||
}
|
||||
}
|
||||
|
||||
private static FocasDriver OneDevice(FakeFocasClientFactory factory, bool coalesce, params string[] addresses) => new(
|
||||
new FocasDriverOptions
|
||||
{
|
||||
Devices = [new FocasDeviceOptions(HostA, DeviceName: "A")],
|
||||
RawTags = [.. addresses.Select(a => FocasRawTags.Entry(new FocasTagDefinition($"raw/{a}", "A", a, FocasDataType.Byte)))],
|
||||
Probe = new FocasProbeOptions { Enabled = false },
|
||||
PmcCoalesce = new FocasPmcCoalesceOptions { Enabled = coalesce },
|
||||
Timeout = TimeSpan.FromMilliseconds(200),
|
||||
}, "focas-linkdown", factory);
|
||||
|
||||
/// <summary>
|
||||
/// #740 review round 2 N1 — a status the CNC RETURNED (EW_REJECT and every unlisted rc map to
|
||||
/// BadCommunicationError) proves the device answered, so it must not end the device's batch: the tags after it
|
||||
/// still read. Before the fix, a deterministic rc on the first tag starved every later tag forever.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public async Task A_returned_comms_status_does_not_fail_the_rest_of_the_batch()
|
||||
{
|
||||
var client = new CountingClient { Values = { ["R101"] = (sbyte)1, ["R102"] = (sbyte)2 } };
|
||||
client.ReadStatuses["R100"] = FocasStatusMapper.MapFocasReturn(13); // EW_REJECT ⇒ BadCommunicationError
|
||||
var drv = OneDevice(new FakeFocasClientFactory { Customise = () => client }, coalesce: false, "R100", "R101", "R102");
|
||||
await drv.InitializeAsync("{}", CancellationToken.None);
|
||||
|
||||
var snaps = await drv.ReadAsync(["raw/R100", "raw/R101", "raw/R102"], CancellationToken.None);
|
||||
|
||||
snaps[0].StatusCode.ShouldBe(FocasStatusMapper.BadCommunicationError);
|
||||
snaps[1].StatusCode.ShouldBe(FocasStatusMapper.Good);
|
||||
snaps[2].Value.ShouldBe((sbyte)2);
|
||||
client.Reads.ShouldBe(3, "every tag was really read");
|
||||
await drv.ShutdownAsync(CancellationToken.None);
|
||||
}
|
||||
|
||||
/// <summary>Positive control for N1: a TIMEOUT (no reply at all) still fails the rest of the batch without reading it.</summary>
|
||||
[Fact]
|
||||
public async Task A_timeout_still_fails_the_rest_of_the_batch_fast()
|
||||
{
|
||||
var client = new CountingClient { TimeoutAt = "R100", Values = { ["R101"] = (sbyte)1 } };
|
||||
var drv = OneDevice(new FakeFocasClientFactory { Customise = () => client }, coalesce: false, "R100", "R101", "R102");
|
||||
await drv.InitializeAsync("{}", CancellationToken.None);
|
||||
|
||||
var snaps = await drv.ReadAsync(["raw/R100", "raw/R101", "raw/R102"], CancellationToken.None);
|
||||
|
||||
snaps.ShouldAllBe(s => s.StatusCode == FocasStatusMapper.BadCommunicationError);
|
||||
client.Reads.ShouldBe(1, "only the tag that timed out touched the wire");
|
||||
await drv.ShutdownAsync(CancellationToken.None);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Review round 2 m5 — the coalescer's link-down paths: a transport fault on the first merged range fails the
|
||||
/// second range WITHOUT a second range read, and the per-tag tags of the same device without a per-tag read.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public async Task Coalescer_transport_fault_fails_later_ranges_and_per_tag_tags_without_reading_them()
|
||||
{
|
||||
var client = new CountingClient { ThrowOnPmcRange = true };
|
||||
// Two ranges far apart (gap > MaxGapBytes) + one lone tag that takes the per-tag path.
|
||||
var drv = OneDevice(new FakeFocasClientFactory { Customise = () => client }, coalesce: true,
|
||||
"R100", "R101", "R500", "R501", "D900");
|
||||
await drv.InitializeAsync("{}", CancellationToken.None);
|
||||
|
||||
var snaps = await drv.ReadAsync(["raw/R100", "raw/R101", "raw/R500", "raw/R501", "raw/D900"], CancellationToken.None);
|
||||
|
||||
snaps.ShouldAllBe(s => s.StatusCode == FocasStatusMapper.BadCommunicationError);
|
||||
client.PmcRangeReads.Count.ShouldBe(1, "the second range must not pay another transport attempt");
|
||||
client.Reads.ShouldBe(0, "the per-tag tag must not pay one either");
|
||||
await drv.ShutdownAsync(CancellationToken.None);
|
||||
}
|
||||
|
||||
/// <summary>Review round 2 m5 — a coalescer CONNECT failure fails the per-tag tags of the device without a second connect.</summary>
|
||||
[Fact]
|
||||
public async Task Coalescer_connect_failure_fails_per_tag_tags_without_reconnecting()
|
||||
{
|
||||
var factory = new FakeFocasClientFactory { Customise = () => new CountingClient { ThrowOnConnect = true } };
|
||||
var drv = OneDevice(factory, coalesce: true, "R100", "R101", "D900");
|
||||
await drv.InitializeAsync("{}", CancellationToken.None);
|
||||
|
||||
var snaps = await drv.ReadAsync(["raw/R100", "raw/R101", "raw/D900"], CancellationToken.None);
|
||||
|
||||
snaps.ShouldAllBe(s => s.StatusCode == FocasStatusMapper.BadCommunicationError);
|
||||
factory.Clients.Count.ShouldBe(1, "one connect attempt per device per batch");
|
||||
factory.Clients.Sum(c => c.ConnectCount).ShouldBe(1);
|
||||
await drv.ShutdownAsync(CancellationToken.None);
|
||||
}
|
||||
|
||||
/// <summary>Results land at their own indices whatever order the devices finish in.</summary>
|
||||
[Fact]
|
||||
public async Task Results_keep_their_request_order_across_devices()
|
||||
|
||||
Reference in New Issue
Block a user