docs(mqtt): P1 plain-MQTT milestone live-verified; endpoint recorded
Task 14 — the P1 milestone gate. Ran the live /run verification on a docker-dev
rig against the real Mosquitto TLS+auth fixture, and recorded the result.
The gate did its job: it found MQTT was unauthorable in production.
RawDriverTypeDialog's driver-type list is a hand-maintained array that nobody
added MQTT to, so the /raw "New driver" picker never offered it — with every
other layer (contracts, driver, browser, factory, host registration, typed tag
editor) complete and 266 green unit tests. Nothing tied that array to
DriverTypeNames and AdminUI has no bUnit, so no offline test could see it.
Fixed, plus RawDriverTypeDialogParityTests: a reflection parity guard that
fails for ANY DriverTypeNames entry missing from the picker. Verified
falsifiable — RED with "…cannot be authored from the /raw New-driver picker,
so they are unreachable in production: Mqtt" before the one-line fix.
A second gap is left OPEN and documented, not fixed (no task ever covered it):
MqttDriverForm / MqttDeviceForm do not exist, and DriverConfigModal/DeviceModal
have no raw-JSON fallback — so an operator can create an MQTT driver but cannot
author its broker endpoint or credentials. P1 is not operator-complete until
those two razor forms land. The gate authored config via SQL to get past it.
Live gate result (isolated 2-node MAIN stack, image built from this branch,
fixture at 10.100.0.35:8883, AllowUntrustedServerCertificate rather than
pinning the CA into the rig):
- typed MQTT tag editor renders and round-trips; Json shows the JSON-path
field, Raw/Scalar hide it; wildcard topic a/+/c blocked at save; data-type
list offers Float64 and no Double; qos/retainSeed absent on "(driver
default)" and qos:2 written as a number; isHistorized/historianTagname
survive a topic-only edit; SparkplugB renders the P2 placeholder and
switching back keeps Plain values; jsonPath is guidance not a gate in all
three shapes ($ seeded only for a brand-new blank tag, blank stays absent,
clearing saves fine)
- deployed, and both editor-written blobs resolved and served changing live
values through OPC UA (22.8 / 1629, StatusCode Good) — no BadNodeIdUnknown
- the bespoke #-observation browser drove a real broker session and rendered
the fixture's actual topic tree (line1/{counter,state,temperature},
noise/chatter, retained/seed); a Modbus device's picker still correctly
reports "Browsing unavailable"
Also found live and documented (not a code change): both nodes of a redundant
pair run the driver, so a FIXED clientId makes them evict each other forever —
the broker logs "already connected, closing old connection" and both nodes
reconnect every ~2s while still reporting Healthy. Unset (the default) is
correct; confirmed 0 reconnects/60s on both nodes after removing it.
Suites: offline 1134 passed / 0 failed (266 Driver.Mqtt + 730 AdminUI incl. the
3 new guards + 138 Core.Abstractions); live 7/7 against the fixture.
Docs: new docs/drivers/Mqtt.md + Mqtt-Test-Fixture.md (the per-driver + fixture
convention every other driver follows), MQTT rows in docs/drivers/README.md,
TestConnectProbes.md, root README.md, and infra/README.md §3.
CLAUDE.md drift corrected while adding the MQTT endpoints:
- the "every fixture carries project: lmxopcua" claim was false — only the
MQTT fixture does; the filter returns one stack, not the fleet
- lmxopcua-fix.ps1 is Windows-VM-only; on macOS drive the host over ssh/rsync
(and the docker-dev rig itself runs locally under OrbStack)
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
This commit is contained in:
@@ -1,6 +1,6 @@
|
||||
# OtOpcUa
|
||||
|
||||
OPC UA server (.NET 10 AnyCPU) that exposes a fleet of industrial drivers as a single OPC UA address space. Drivers ship in-process for AVEVA System Platform Galaxy (via the sibling `mxaccessgw` repo), Modbus TCP, Siemens S7, Allen-Bradley CIP (ControlLogix / CompactLogix), Allen-Bradley Legacy (SLC 500 / MicroLogix), Beckhoff TwinCAT (ADS), FANUC FOCAS, and OPC UA Client (gateway).
|
||||
OPC UA server (.NET 10 AnyCPU) that exposes a fleet of industrial drivers as a single OPC UA address space. Drivers ship in-process for AVEVA System Platform Galaxy (via the sibling `mxaccessgw` repo), Modbus TCP, Siemens S7, Allen-Bradley CIP (ControlLogix / CompactLogix), Allen-Bradley Legacy (SLC 500 / MicroLogix), Beckhoff TwinCAT (ADS), FANUC FOCAS, OPC UA Client (gateway), and MQTT (broker subscribe; Sparkplug B in progress).
|
||||
|
||||
A cross-platform client stack (.NET 10) — shared library, CLI, and Avalonia desktop app — connects to any OPC UA server.
|
||||
|
||||
@@ -15,7 +15,7 @@ A cross-platform client stack (.NET 10) — shared library, CLI, and Avalonia de
|
||||
| address space + capability fan-out|
|
||||
+-------------------------------------+
|
||||
| | | | | | | |
|
||||
Galaxy Modbus S7 AbCip AbLeg TwinCAT FOCAS OpcUaClient
|
||||
Galaxy Modbus S7 AbCip AbLeg TwinCAT FOCAS OpcUaClient MQTT
|
||||
|
|
||||
v
|
||||
mxaccessgw (sibling repo, gRPC)
|
||||
@@ -91,7 +91,7 @@ See [docs/Client.CLI.md](docs/Client.CLI.md) and [docs/Client.UI.md](docs/Client
|
||||
|---|---|
|
||||
| Driver specs (per-driver capability surface, config, addressing) | [docs/v2/driver-specs.md](docs/v2/driver-specs.md) |
|
||||
| Galaxy driver | [docs/drivers/Galaxy.md](docs/drivers/Galaxy.md) |
|
||||
| Modbus / S7 / AbCip / AbLegacy / TwinCAT / FOCAS / OpcUaClient | [docs/drivers/](docs/drivers/) |
|
||||
| Modbus / S7 / AbCip / AbLegacy / TwinCAT / FOCAS / OpcUaClient / MQTT | [docs/drivers/](docs/drivers/) |
|
||||
| Galaxy parity rig (mxaccessgw setup) | [docs/v2/Galaxy.ParityRig.md](docs/v2/Galaxy.ParityRig.md) |
|
||||
| Galaxy performance + tracing | [docs/v2/Galaxy.Performance.md](docs/v2/Galaxy.Performance.md) |
|
||||
|
||||
|
||||
Reference in New Issue
Block a user