fix(tagconfig): close the four #551 residuals — accept-gate-first Inspect, three authoring rules, CSV/service gate, doc sweep
Gitea #551. 1. CSV import ran no driver-typed config gate. Its typed columns were always strictly parsed, but the free-form TagConfigJson column reached the database unread, so a CSV could author a tag the driver rejects — one that deploys green and reads BadNodeIdUnknown forever. RawTagCsvMapper.Parse now names the offending row in the staged review grid, and RawTreeService enforces the same gate on CreateTag/UpdateTag/ImportTags: a form cannot be the guarantee (the API and any future caller reach none of them, and this repo has no bUnit). A rejected import row is an ERROR — the batch inserts nothing and the row is named — never a skip. Note the brief's premise that manual entry rides ImportTagsAsync is wrong: RawManualTagEntryModal commits row-by-row via CreateTagAsync, which is why the gate had to land on all three write paths. 2/3. The seven pre-#549 Inspect methods ran a hand-list of DescribeInvalidEnum checks, so every rejection cause not on the list was invisible. They are now ACCEPT-GATE-FIRST (the MTConnect/Sql/OpcUaClient/Calculation shape): ask the driver's own reader for the verdict, then explain the refusal, with a catch-all so "the parse rejects but Inspect said nothing" is unreachable. That closes S7's absent dataType, AbCip members[], Modbus stringByteOrder and the type-dependent guards, plus causes the issue did not name (absent region/address/tagPath/symbolPath/topic, TwinCAT Structure, MQTT's Sparkplug tuple). FOCAS and MQTT keep advisories about ACCEPTED blobs, so they diagnose rather than return empty. Authoring half: ModbusTagConfigModel gains stringByteOrder; AbCipTagConfigModel asks the new AbCipTagDefinitionFactory.DescribeInvalidMember; S7TagConfigModel captures whether the SOURCE blob declared dataType and asks S7TagDefinitionFactory.DataTypeKey/DeclaresDataType. One authority per rule. 4. Doc sweep: the six factory Inspect summaries, EquipmentTagConfigInspector's class remarks and AdminOperationsActor's comment all claimed invalid enums are "silently defaulted by the lenient runtime" — false since R2-11 Phase C made the runtime reads strict. They describe rejections now.
This commit is contained in:
+104
-14
@@ -130,18 +130,41 @@ public static class ModbusTagDefinitionFactory
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Deploy-time inspection of an equipment-tag <c>TagConfig</c> blob (05/CONV-2). Returns
|
||||
/// human-readable warnings for present-but-invalid enum values (<c>region</c> / <c>dataType</c> /
|
||||
/// <c>byteOrder</c> — which the lenient runtime silently defaults) and for a structurally
|
||||
/// unparseable TagConfig (which the runtime turns into a silent <c>BadNodeIdUnknown</c>). Empty when
|
||||
/// the blob is clean or is not an equipment-tag TagConfig object. Never throws.
|
||||
/// The RawPath handed to <see cref="FromTagConfig"/> during inspection. The mapper only copies it
|
||||
/// onto <see cref="ModbusTagDefinition.Name"/> and never validates it, so inspection is free to pass
|
||||
/// a placeholder — the deploy gate is inspecting a blob, not a placed tag.
|
||||
/// </summary>
|
||||
private const string InspectionRawPath = "(inspect)";
|
||||
|
||||
/// <summary>
|
||||
/// Deploy-time inspection of an equipment-tag <c>TagConfig</c> blob (05/CONV-2). Returns
|
||||
/// human-readable warnings for a blob <see cref="FromTagConfig"/> would <b>reject</b> — a
|
||||
/// structurally unparseable or non-object document, an absent <c>region</c>, an absent or
|
||||
/// out-of-range <c>address</c>, a present-but-invalid <c>region</c> / <c>dataType</c> /
|
||||
/// <c>byteOrder</c> / <c>stringByteOrder</c> (each rejects the tag: the runtime enum reads are
|
||||
/// STRICT since R2-11 Phase C), or a type-dependent guard (<c>String</c> with no
|
||||
/// <c>stringLength</c>, <c>BitInRegister</c> with a <c>bitIndex</c> outside 0–15). Such a tag is
|
||||
/// skipped by the driver and reads <c>BadNodeIdUnknown</c> forever. Empty when the mapper accepts
|
||||
/// the blob, when it is blank, or when it is not an equipment-tag TagConfig object. Never throws.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <b>The verdict comes from <see cref="FromTagConfig"/>, not from a mirror</b> (Gitea #551). The
|
||||
/// rule this gate must never break is being stricter than the runtime — a blob the driver serves
|
||||
/// must not draw a warning calling it invalid — and running the mapper first makes that structural
|
||||
/// rather than a promise. It also closes the opposite gap: the previous hand-list of enum checks
|
||||
/// was silent for every rejection cause that was not on it (an absent <c>region</c>, a bad
|
||||
/// <c>address</c>, <c>stringByteOrder</c>), so a tag the driver refuses deployed clean.
|
||||
/// </remarks>
|
||||
/// <param name="reference">The equipment tag's TagConfig JSON.</param>
|
||||
/// <returns>The warnings; empty when clean.</returns>
|
||||
public static IReadOnlyList<string> Inspect(string reference)
|
||||
{
|
||||
var warnings = new List<string>();
|
||||
if (string.IsNullOrWhiteSpace(reference) || reference[0] != '{') return warnings;
|
||||
|
||||
// The accept gate: whatever the driver reads draws nothing. See the remarks.
|
||||
if (FromTagConfig(reference, InspectionRawPath, out _)) return warnings;
|
||||
|
||||
try
|
||||
{
|
||||
using var doc = JsonDocument.Parse(reference);
|
||||
@@ -151,23 +174,90 @@ public static class ModbusTagDefinitionFactory
|
||||
warnings.Add("Modbus TagConfig root is not a JSON object — the tag will not resolve (BadNodeIdUnknown).");
|
||||
return warnings;
|
||||
}
|
||||
foreach (var w in new[]
|
||||
{
|
||||
TagConfigJson.DescribeInvalidEnum<ModbusRegion>(root, "region"),
|
||||
TagConfigJson.DescribeInvalidEnum<ModbusDataType>(root, "dataType"),
|
||||
TagConfigJson.DescribeInvalidEnum<ModbusByteOrder>(root, "byteOrder"),
|
||||
})
|
||||
{
|
||||
if (w is not null) warnings.Add(w);
|
||||
}
|
||||
|
||||
DescribeRejection(root, warnings);
|
||||
}
|
||||
catch (JsonException)
|
||||
{
|
||||
warnings.Add("Modbus TagConfig is not valid JSON — the tag will not resolve (BadNodeIdUnknown).");
|
||||
return warnings;
|
||||
}
|
||||
|
||||
// Backstop: the mapper refused for a reason nothing above names (it also swallows FormatException
|
||||
// and InvalidOperationException). Saying so beats reporting a clean blob the driver will skip.
|
||||
if (warnings.Count == 0)
|
||||
{
|
||||
warnings.Add(
|
||||
"Modbus TagConfig was rejected by the driver's tag reader — the driver will skip this tag "
|
||||
+ "and it will read BadNodeIdUnknown.");
|
||||
}
|
||||
|
||||
return warnings;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Explains why <see cref="FromTagConfig"/> refused an object-rooted blob, walking its checks in the
|
||||
/// same order. Every branch mirrors a <c>return false</c> there — and it runs only after the mapper
|
||||
/// has already refused, so it can never invent strictness of its own.
|
||||
/// </summary>
|
||||
/// <param name="root">The TagConfig root object.</param>
|
||||
/// <param name="warnings">The list to append warnings to.</param>
|
||||
private static void DescribeRejection(JsonElement root, List<string> warnings)
|
||||
{
|
||||
if (!root.TryGetProperty("region", out _))
|
||||
{
|
||||
warnings.Add(
|
||||
"Modbus TagConfig has no 'region' — every Modbus tag must name one (valid: "
|
||||
+ string.Join(", ", Enum.GetNames<ModbusRegion>())
|
||||
+ "); the driver will skip this tag and it will read BadNodeIdUnknown.");
|
||||
}
|
||||
|
||||
if (!root.TryGetProperty("address", out var addr))
|
||||
{
|
||||
warnings.Add("Modbus TagConfig has no 'address' — the tag will not resolve (BadNodeIdUnknown).");
|
||||
}
|
||||
else if (addr.ValueKind != JsonValueKind.Number
|
||||
|| !addr.TryGetInt32(out var address)
|
||||
|| address < 0 || address > ushort.MaxValue)
|
||||
{
|
||||
warnings.Add(
|
||||
$"value '{addr.GetRawText()}' for 'address' is not a Modbus register address (an integer "
|
||||
+ $"0–{ushort.MaxValue}); the tag will not resolve (BadNodeIdUnknown).");
|
||||
}
|
||||
|
||||
// Strict enums, in the order FromTagConfig reads them. stringByteOrder is read as strictly as its
|
||||
// three siblings, and was the one the previous hand-list forgot (Gitea #551).
|
||||
foreach (var w in new[]
|
||||
{
|
||||
TagConfigJson.DescribeInvalidEnum<ModbusRegion>(root, "region"),
|
||||
TagConfigJson.DescribeInvalidEnum<ModbusDataType>(root, "dataType"),
|
||||
TagConfigJson.DescribeInvalidEnum<ModbusByteOrder>(root, "byteOrder"),
|
||||
TagConfigJson.DescribeInvalidEnum<ModbusStringByteOrder>(root, "stringByteOrder"),
|
||||
})
|
||||
{
|
||||
if (w is not null) warnings.Add(w);
|
||||
}
|
||||
|
||||
// Type-dependent guards. The byte/ushort NARROWING is part of the rule, not an accident of the
|
||||
// mapper: it reads `(byte)bitIndex` / `(ushort)stringLength`, so 256 is bit 0 and is ACCEPTED.
|
||||
// Describing the un-narrowed value here would call a blob invalid that the driver serves.
|
||||
if (!TagConfigJson.TryReadEnumStrict(root, "dataType", ModbusDataType.Int16, out var dataType)) return;
|
||||
|
||||
if (dataType == ModbusDataType.String && (ushort)ReadInt(root, "stringLength") < 1)
|
||||
{
|
||||
warnings.Add(
|
||||
"Modbus String tag has no 'stringLength' of at least 1 — a zero-length string reads zero "
|
||||
+ "registers, which is an illegal Modbus request, so the tag is rejected (BadNodeIdUnknown).");
|
||||
}
|
||||
|
||||
if (dataType == ModbusDataType.BitInRegister && (byte)ReadInt(root, "bitIndex") > 15)
|
||||
{
|
||||
warnings.Add(
|
||||
"Modbus BitInRegister tag has a 'bitIndex' outside 0–15 — the bit mask would overflow a "
|
||||
+ "16-bit register, so the tag is rejected (BadNodeIdUnknown).");
|
||||
}
|
||||
}
|
||||
|
||||
private static int ReadInt(JsonElement o, string name)
|
||||
=> o.TryGetProperty(name, out var e) && e.ValueKind == JsonValueKind.Number
|
||||
&& e.TryGetInt32(out var v) ? v : 0;
|
||||
|
||||
Reference in New Issue